12.7/22kV Aluminum Single Core Type MV Cable

12.7/22kV Aluminum Single Core Type MV Cable
Details:
Compliance
• Conductor resistance AS/NZS 1125
• Insulation resistance AS/NZS 1429.1
• Voltage test AS/NZS 1429.1
Standard and References
• AS/NZS 1429.1
• AS/NZS 1125
• AS/NZS 3808
Send Inquiry
Download
Description
Technical Parameters
Certification
AL MV Cable

 

12.7/22kV Aluminum Single Core Type MV Cable

Single core Type MV cable are designed to resist the harmful effects of chemicals, including oils, solvents, acids, and alkalines. The chemical resistance of the materials used in this cable helps prevent corrosion or deterioration, maintaining the structural integrity and performance of the cable.

 

characteristics

 

 

12.7/22kV Type MV cable can be used in urban underground cable systems. They have corrosion resistance and moisture resistance. They are widely used underground in cities to connect different distribution points and users, and can avoid being affected by groundwater and other corrosive substances.

MV cable application

 

Feature

 

Single Core AL MV Cable

 

• Conductor: Stranded Compacted Circular aluminium conductor as per AS/NZS 1125

• Conductor Screen: Extruded Semi-conductive compound

• Insulation: XLPE

• Insulation Screen: Extruded

• Longitudinal Water blocking : Water blocking tape above and below strippable Semi-conductive compound

copper screen (Optional)

• Metallic Insulation Screen: Copper Wire Screen + helically applied copper tape (E/F current capacity – Based on requirement)

• Metallic Sheath: Lead Alloy (optional)

• Outer Sheath: Extruded Polyvinyl Chloride, Colour: Black

(Alternative Sheath: PVC+HDPE Composite Sheath or LSZH Outer sheath and parameters will change accordingly)

 

Certification

 

 

Copper MV underground cable has obtained SAA certification, with certification numbers: SAA242046 and SAA250307 (available on the certification website). Quality assurance is crucial for large-scale engineering projects. Cables are the foundation of project safety, and selecting certified cables ensures smooth project execution. SAA-certified cables undergo rigorous durability, reliability, and safety testing. They meet stringent technical specifications and can withstand demanding operating conditions.

SAA medium voltage cable

 

Package

 

THHN wire package

 

Production Line

 

thhn cable factory

 

Greater Wire Manufacturer ensures that every stage meets the requirements of environmental protection, quality, and economic benefits through scientific management of the entire product life cycle. For example, the factory takes environmental protection and recyclability into consideration during the product design stage, uses environmentally friendly materials and processes during the production process, provides reliable technical support and after-sales service during the use stage, and can recycle and reuse materials when the product is scrapped. Full life cycle management not only helps reduce the impact on the environment but also provides more added value to customers.

 

Case

 

Company cases

 

Partner

 

greater wire Partner

 

FAQ

 

Q: What is the importance of SAA certification for medium voltage cables?

A: SAA certification ensures that medium voltage cables meet the legal and safety requirements of the Australian and New Zealand markets, ensuring that the cables are safe and reliable in actual use.

Q: How is the quality of these products?

A: Our products have passed many certifications, such as UL, SAA, TUV, CE, CB, and others. Over 20 years of experience in this area, Providing wires and cables to more than 90 countries around the world.

Q: Is logo printing an option for the cables?

A: Yes, customization with your logo is available for wires and cables.

 

 

Hot Tags: 12.7/22kv aluminum single core type mv cable, China 12.7/22kv aluminum single core type mv cable manufacturers, suppliers, factory, ul1007 hook up wire, ac cable, rubber welding cable, nmd90, AC Power Cable, cul standard rw75 rw90 rwu75 rwu90 cable

AL MV Cable

Single Core AL MV Cable

No. of
Cores

 

Core Cross
sectional
Area
Nominal Diameter
Under
metallic
screen
Under
metallic
screen
Overall
No.
mm2
mm
mm
mm
1 35 21.1 23.0 27.0
1 50 22.2 24.1 28.0
1 70 23.8 25.7 30.0
1 95 25.4 27.3 31.0
1 120 27 28.9 33.0
1 150 28.3 30.2 35.0
1 185 30 31.9 36.0
1 240 32.3 34.2 39.0
1 300 34.5 36.4 41.0
1 400 37.2 39.1 44.0
1 500 40.6 42.5 48.0
1 630 43.8 45.7 51.0
1 800 47.7 49.6 55.0
1 1000 52.2 54.1 60.0
• Above mentioned parameters are based on 3k A/sec earth fault current capacity of copper screen
 
ELECTRICAL CHARACTERISTICS:
No.of Cores
Core Cross sectional Area
Max. DC Resistance at 20˚C
Max. AC Resistance at 90˚C
Approx. Capacitance
Approx. Inductance
Approx.

 Reactance

Continuous Current Rating
In ground at  20℃
In Duct at
20℃
In air at 30℃

 Flat

Trefoil
Flat
Trefoil
Flat
Trefoil
No.
mm2
Ω/km
Ω/km
µF/km
mH/km
Ω/km
Amps
1 35 0.868 1.113 0.16 0.472 0.148 134 129 123 122 157 154
1 50 0.641 0.822 0.17 0.450 0.142 157 152 146 142 189 184
1 70 0.443 0.568 0.2 0.418 0.131 192 186 178 176 236 230
1 95 0.32 0.411 0.22 0.397 0.125 229 221 213 210 287 280
1 120 0.253 0.325 0.24 0.379 0.119 260 252 242 240 332 324
1 150 0.206 0.265 0.25 0.368 0.116 288 281 271 267 376 368
1 185 0.164 0.211 0.28 0.358 0.112 324 317 307 303 432 424
1 240 0.125 0.162 0.31 0.341 0.107 373 367 356 351 511 502
1 300 0.1 0.130 0.33 0.329 0.103 419 414 402 397 586 577
1 400 0.0778 0.102 0.37 0.318 0.100 466 470 457 451 676 673
1 500 0.0605 0.080 0.41 0.306 0.096 525 530 510 505 760 750
1 630 0.0469 0.064 0.45 0.297 0.093 580 585 560 555 860 850
1 800 0.0367 0.051 0.5 0.288 0.090 650 655 620 615 960 950
1 1000 0.0291 0.043 0.56 0.279 0.088 715 705 670 665 1060 1050
*: Current Ratings are based on IEC 60502-2 & IEC 60287, Max. Conductor Temperature at 90℃, Ambient temperature at 30℃ in Air / at 20℃ in Ground, Thermal resistivity of Soil 1.5 k.m/W & for earthenware ducts 1.2k.m/W and Depth of Laying 0.8m.
Current rating de-rating factors for other than 30℃ ambient air temperature.
20 25 35 40 45 50 55 60
1.08 1.04 0.96 0.91 0.87 0.82 0.76 0.71

 

Current rating de-rating factors for other than 20℃ ground temperature.
10 15 25 30 35 40 45 50
1.07 1.04 0.96 0.93 0.89 0.85 0.80 0.76

 

No.of Cores
Core Cross sectional Area
Max. pulling tension on conductor
Charging Current per phase
Zero sequence impedance
Electric Stress at Conductor Screen
Short circuit rating of Phase conductor
No. mm² kN Amps/Km Ohms/Km kV/mm kA, I sec
1 35 1.75 0.64 2.27 3.7 3.3
1 50 2.5 0.68 1.98 3.5 4.7
1 70 3.5 0.8 1.73 3.4 6.6
1 95 4.75 0.88 1.57 3.2 9.0
1 120 6 0.96 1.49 3.1 11.3
1 150 7.5 1 1.42 3.1 14.2
1 185 9.25 1.12 1.37 3.0 17.4
1 240 12 1.24 1.32 2.9 22.6
1 300 15 1.32 1.29 2.9 28.3
1 400 20 1.48 1.26 2.8 37.6
1 500 25 1.64 1.24 2.7 47.2
1 630 31.5 1.8 1.22 2.7 59.6
1 800 40 1.99 1.21 2.7 75.6
1 1000 50 2.23 1.20 2.6 94.5

 

MV Cable

MV cable 02

Send Inquiry