EN 50525-2-31 Cable – EN 50525-2-31 Flexible PVC Solution

EN 50525-2-31 Cable – EN 50525-2-31 Flexible PVC Solution
Details:
·Conductor: Class 5 flexible copper conductor
·Insulation: PVC (Polyvinyl Chloride)
·Voltage Rating Uo/U: H05V-K:300/500V ; H07V-K:450/750V
·Temperature Rating: Fixed: -30°C to +70℃ ; Flexed: -5°C to +70℃
·Standards: EN 50525-2-31, EN 60228 ; Flame Retardant according to IEC/EN 60332-1-2 ; UV Resistant
Send Inquiry
Download
Description
Technical Parameters
Certification

internal wiring cable for factory machine internal wiring

PRODUCT REAL SHOT

 

H05V-K wire for electrical enclosures
single core flexible wire for factory machine internal wiring
H05V-K cable for electrical enclosures

flexible panel wire for electrical enclosures

H05V-K harmonised flexible wire for Efficient Panel Production and Terminal Work
For engineering teams that purchase against harmonised cable designations, conductor class, voltage and installation handling are key purchasing points. H05V-K is a 300/500V Class 5 copper wire with PVC insulation for European-style internal wiring and equipment assembly. This page captures precise searches including EN 60228 Class 5 wire, harmonised panel wire and 300/500V H05V-K cable. GERITEL WIRE can provide technical data needed for drawing review and order confirmation. Technical confirmation should precede production so the specified size, colour and construction match the project. GERITEL WIRE can confirm construction, colour and packing details before volume production.
PRODUCT SPECIFICATIONS

 

PVC insulated wire for electrical enclosures

Applications

 

PVC panel wiring for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.

SPECIFICATIONS
Voltage Rating Uo/U

H05V-K:300/500V

H07V-K:450/750V

Temperature Rating

Fixed: -30°C to +70°C

Flexed: -5°C to +70°C

Minimum Bending Radius Fixed: 6 x overall diameter
Conductor Class 5 flexible copper conductor
Insulation PVC (Polyvinyl Chloride)
Insulation Colour Red,Black,Blue,Orange,Yellow,White,Green/Yellow,Violet,Pink,Grey,Brown
STANDARDS

EN 50525-2-31,EN 60228

Flame Retardant according to IEC/EN 60332-1-2

UV Resistant

DIMENSIONS

NOMINAL CROSS SECTIONAL AREA

mm²

NOMINAL OVERALL DIAMETER

mm²

NOMINAL WEIGHT

kg/km

H05V-K
0.5 2.20 9.1
0.75 2.40 11.7
1 2.55 14.4
H07V-K
1.5 3.00 20.1
2.5 3.65 31.5
4 4.20 46.2
6 4.80 65.1
10 6.25 109.4
16 7.40 165.2
25 9.40 253.4
35 10.40 345.5
50 12.55 492.4
70 14.10 669.3
95 17.20 910.4
120 17.70 1129.4
150 19.60 1401.0
185 23.00 1741.0
240 26.40 2267.5

CONDUCTORS

NOMINAL CROSS

SECTIONAL AREA

mm²

MAXIMUM DIAMETER

OF WIRES IN CONDUCTOR

mm

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Plain Wires
0.5 0.21 39
0.75 0.21 26
1 0.21 19.5
1.5 0.26 13.3
2.5 0.26 7.98
4 0.31 4.95
6 0.31 3.3
10 0.41 1.91
16 0.41 1.21
25 0.41 0.78
35 0.41 0.554
50 0.41 0.386
70 0.51 0.272
95 0.51 0.206
120 0.51 0.161
150 0.51 0.129
185 0.51 0.106
240 0.51 0.0801

ELECTRICAL CHARACTERISTICS

NOMINAL CROSSS

ECTIONAL AREA

mm²

REFERENCE METHOD A

(ENCLOSED IN

CONDUIT IN THERMALLY

INSULATING WALL ETC)

Amps

REFERENCE METHOD B

(ENCLOSED IN CONDUIT

IN WALL OR IN

TRUNKING ETC)
Amps

REFERENCE METHOD C

(CLIPPED DIRECT)
Amps

REFERENCE METHOD F

(IN FREE AIR OR ONA PERFORATED CABLE TRAY ETC HORIZONTAL OR VERTICAL ETC)

Amps

Touching

Spaced by

one diameter

2 Cables Single-Phase ACor DC or3 Cables Three-Phase AC flat

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

AC or DC

3 or 4Cables

Three-Phase

AC

2Cables

SinglePhase

AC or DCflat

3Cables

Three-Phase

ACflat

3 Cables

Three-Phase

ACtrefoil

Horizontal Vertical
1.5 14.5 13.5 17.5 15.5 20 18 - - - - -
2.5 20 18 24 21 27 25 - - - - -
4 26 24 32 28 37 33 - - - - -
6 34 31 41 36 47 43 - - - - -
10 46 42 57 50 65 59 - - - - -
16 61 56 76 68 87 79 - - - - -
25 80 73 101 89 114 104 131 114 110 146 130
35 99 89 125 110 141 129 162 143 137 181 162
50 119 108 151 134 182 167 196 174 167 219 192
70 151 136 192 171 234 214 251 225 216 281 254
95 182 164 232 207 284 261 304 275 264 341 311
120 210 188 269 239 330 303 352 321 308 396 362
150 240 216 300 262 381 349 406 372 356 456 419
185 273 245 341 296 436 400 463 427 409 521 480
240 321 286 400 346 515 472 546 507 485 615 569
CERTIFICATIONS

 

Class 5 copper wire for electrical enclosures

300/500V wire for electrical enclosures

PACKAGING

 

flexible panel wire for switchboards

Roll

internal wiring cable for electrical enclosures

Plastic Reel

single core flexible wire for electrical enclosures

Small Wooden Reel

APPLICATION

 

H05V-K wire for panel builder wiring
Industrial Control Panel
H05V-K cable for panel builder wiring
Renewable Energy Power Connection
Class 5 copper wire for switchboards

Switchboard Wiring

 

CASE

 

H05V-K cable for switch cabinets

Adelaide Airport Switchboard Upgrade

flexible panel wire for panel builder wiring

Industrial Main Switchboard Power Distribution

PVC insulated wire for panel builder wiring

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

Class 5 copper wire for panel builder wiring
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

internal wiring cable for panel builder wiring
 
300/500V wire for panel builder wiring
 
Class 5 copper wire for switch cabinets
 
300/500V wire for switch cabinets
 
single core flexible wire for panel builder wiring
 
H05V-K wire for OEM equipment wiring
 
GLOBAL CERTIFICATIONS

 

H05V-K cable for OEM equipment wiring

CUSTOMER PHOTOS
 

flexible panel wire for OEM equipment wiring

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

PVC insulated wire for OEM equipment wiring
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

Class 5 copper wire for OEM equipment wiring
300/500V wire for OEM equipment wiring
internal wiring cable for OEM equipment wiring
Class 5 copper wire for electrical cabinets
PVC insulated wire for relay boards
300/500V wire for electrical cabinets
single core flexible wire for relay panels
single core flexible wire for OEM equipment wiring
H05V-K wire for signalling systems
H05V-K cable for signalling systems
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

flexible panel wire for signalling systems
FAQ

 

Can H05V-K be installed on cable tray?
The product can be a good fit, provided the voltage, cross-section and protected-installation conditions are correct. The relevant search term is H05V-K cable tray installation. Cable-tray use depends on the function, local rules and protection; green/yellow equipotential conductors may have specific allowances, while general single cores may require additional protection. Confirm the exact installation method with the electrical designer. GERITEL WIRE can provide the applicable datasheet and available compliance documents for the exact ordered construction for buyer review.
Can H05V-K be installed under plaster?
Buyers should treat this as a selection question rather than a yes/no marketing claim. The relevant search term is H05V-K under plaster. Some harmonised single-core guidance permits protected installation in tubes in or on plaster for signal/internal wiring applications. The conduit or protection system and local building rules remain essential. Where a project has special installation conditions, GERITEL WIRE can help identify whether standard H05V-K is suitable or another cable type is safer.
How should H05V-K be pulled through a long conduit run?
Yes, when the installation conditions match the H05V-K design. The relevant search term is flexible H05V-K installation. Use a suitable pulling method, avoid exceeding bend-radius or pulling-force limits, and prevent insulation damage at conduit edges. If long pulls dominate the project, review whether the chosen single-core construction and conduit design are appropriate. GERITEL WIRE focuses on clear specification confirmation before mass production, especially for voltage, cross-section, colour and certification scope.
Can H05V-K be used for PLC panel wiring?
The key point is to separate the standard cable property from the final installation rule. The relevant search term is H05V-K PLC panel wire. Yes, it can be suitable for protected internal PLC panel circuits when voltage, current, EMC segregation and terminal requirements are satisfied. Use shielding or twisted-pair products where the signal circuit specifically requires them. Distributors and OEM buyers can ask GERITEL WIRE to align packing quantity and label information with stocking or assembly requirements.

 

Hot Tags: en 50525-2-31 cable – en 50525-2-31 flexible pvc solution, China en 50525-2-31 cable – en 50525-2-31 flexible pvc solution manufacturers, suppliers, factory, HO5V-K

Send Inquiry