Details:
·Conductor: Class 5 flexible copper conductor
·Insulation: PVC (Polyvinyl Chloride)
·Voltage Rating Uo/U: H05V-K:300/500V ; H07V-K:450/750V
·Temperature Rating: Fixed: -30°C to +70℃ ; Flexed: -5°C to +70℃
·Standards: EN 50525-2-31, EN 60228 ; Flame Retardant according to IEC/EN 60332-1-2 ; UV Resistant
Send Inquiry
Download
Description
Technical Parameters
Certification

H05V-K cable for industrial automation panels

PRODUCT REAL SHOT

 

PVC insulated wire for industrial automation panels
flexible panel wire for industrial automation panels
Class 5 copper wire for industrial automation panels

300/500V wire for industrial automation panels

0.5mm2 electrical cabinet wire Built for Organized Internal Electrical Assembly
Focused on dense PLC cabinets and compact control-panel terminal sections, this H05V-K page presents a flexible Class 5 copper conductor with PVC insulation in an unsheathed single-core design. Customers may search for 0.5 mm² flexible copper wire, 0.5mm2 panel wiring cable or H05V-K small gauge wire; these terms are mapped to one technically consistent product family. small cross-section and Class 5 flexibility help keep wire bundles manageable inside compact enclosures. Use should remain within suitable protected internal or fixed wiring conditions. GERITEL WIRE can confirm construction, colour and packing details before volume production. OEM printing and reel formats can be reviewed after the final construction is confirmed.
PRODUCT SPECIFICATIONS

 

internal wiring cable for industrial automation panels

Applications

 

PVC panel wiring for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.

SPECIFICATIONS
Voltage Rating Uo/U

H05V-K:300/500V

H07V-K:450/750V

Temperature Rating

Fixed: -30°C to +70°C

Flexed: -5°C to +70°C

Minimum Bending Radius Fixed: 6 x overall diameter
Conductor Class 5 flexible copper conductor
Insulation PVC (Polyvinyl Chloride)
Insulation Colour Red,Black,Blue,Orange,Yellow,White,Green/Yellow,Violet,Pink,Grey,Brown
STANDARDS

EN 50525-2-31,EN 60228

Flame Retardant according to IEC/EN 60332-1-2

UV Resistant

DIMENSIONS

NOMINAL CROSS SECTIONAL AREA

mm²

NOMINAL OVERALL DIAMETER

mm²

NOMINAL WEIGHT

kg/km

H05V-K
0.5 2.20 9.1
0.75 2.40 11.7
1 2.55 14.4
H07V-K
1.5 3.00 20.1
2.5 3.65 31.5
4 4.20 46.2
6 4.80 65.1
10 6.25 109.4
16 7.40 165.2
25 9.40 253.4
35 10.40 345.5
50 12.55 492.4
70 14.10 669.3
95 17.20 910.4
120 17.70 1129.4
150 19.60 1401.0
185 23.00 1741.0
240 26.40 2267.5

CONDUCTORS

NOMINAL CROSS

SECTIONAL AREA

mm²

MAXIMUM DIAMETER

OF WIRES IN CONDUCTOR

mm

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Plain Wires
0.5 0.21 39
0.75 0.21 26
1 0.21 19.5
1.5 0.26 13.3
2.5 0.26 7.98
4 0.31 4.95
6 0.31 3.3
10 0.41 1.91
16 0.41 1.21
25 0.41 0.78
35 0.41 0.554
50 0.41 0.386
70 0.51 0.272
95 0.51 0.206
120 0.51 0.161
150 0.51 0.129
185 0.51 0.106
240 0.51 0.0801

ELECTRICAL CHARACTERISTICS

NOMINAL CROSSS

ECTIONAL AREA

mm²

REFERENCE METHOD A

(ENCLOSED IN

CONDUIT IN THERMALLY

INSULATING WALL ETC)

Amps

REFERENCE METHOD B

(ENCLOSED IN CONDUIT

IN WALL OR IN

TRUNKING ETC)
Amps

REFERENCE METHOD C

(CLIPPED DIRECT)
Amps

REFERENCE METHOD F

(IN FREE AIR OR ONA PERFORATED CABLE TRAY ETC HORIZONTAL OR VERTICAL ETC)

Amps

Touching

Spaced by

one diameter

2 Cables Single-Phase ACor DC or3 Cables Three-Phase AC flat

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

AC or DC

3 or 4Cables

Three-Phase

AC

2Cables

SinglePhase

AC or DCflat

3Cables

Three-Phase

ACflat

3 Cables

Three-Phase

ACtrefoil

Horizontal Vertical
1.5 14.5 13.5 17.5 15.5 20 18 - - - - -
2.5 20 18 24 21 27 25 - - - - -
4 26 24 32 28 37 33 - - - - -
6 34 31 41 36 47 43 - - - - -
10 46 42 57 50 65 59 - - - - -
16 61 56 76 68 87 79 - - - - -
25 80 73 101 89 114 104 131 114 110 146 130
35 99 89 125 110 141 129 162 143 137 181 162
50 119 108 151 134 182 167 196 174 167 219 192
70 151 136 192 171 234 214 251 225 216 281 254
95 182 164 232 207 284 261 304 275 264 341 311
120 210 188 269 239 330 303 352 321 308 396 362
150 240 216 300 262 381 349 406 372 356 456 419
185 273 245 341 296 436 400 463 427 409 521 480
240 321 286 400 346 515 472 546 507 485 615 569
CERTIFICATIONS

 

single core flexible wire for industrial automation panels

H05V-K wire for building automation panels

PACKAGING

 

flexible panel wire for building automation panels

Roll

H05V-K cable for building automation panels

Plastic Reel

PVC insulated wire for building automation panels

Small Wooden Reel

APPLICATION

 

300/500V wire for building automation panels
Industrial Control Panel
Class 5 copper wire for building automation panels
Renewable Energy Power Connection
300/500V wire for motor controllers

Switchboard Wiring

 

CASE

 

single core flexible wire for building automation panels

Adelaide Airport Switchboard Upgrade

internal wiring cable for building automation panels

Industrial Main Switchboard Power Distribution

H05V-K wire for elevator control panels

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

H05V-K cable for elevator control panels
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

PVC insulated wire for elevator control panels
 
flexible panel wire for elevator control panels
 
flexible panel wire for controller cabinets
 
Class 5 copper wire for elevator control panels
 
300/500V wire for elevator control panels
 
Class 5 copper wire for controller cabinets
 
GLOBAL CERTIFICATIONS

 

internal wiring cable for elevator control panels

CUSTOMER PHOTOS
 

single core flexible wire for elevator control panels

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

H05V-K wire for pump control panels
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

flexible panel wire for pump control panels
H05V-K cable for pump control panels
PVC insulated wire for pump control panels
single core flexible wire for pump control panels
H05V-K cable for water treatment control panels
internal wiring cable for pump control panels
300/500V wire for pump control panels
Class 5 copper wire for pump control panels
internal wiring cable for PLC panels
H05V-K wire for water treatment control panels
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

flexible panel wire for water treatment control panels
FAQ

 

Can H05V-K be used for breaker auxiliary contacts?
In panel building, the practical answer depends on how the conductor is protected and terminated. The relevant search term is H05V-K auxiliary contact wire. Yes, fixed internal connections to suitable breaker auxiliary contacts are a common panel-wire duty. Terminal size, short-circuit protection and circuit identification must remain correct. For international orders, GERITEL WIRE can prepare technical and packing information needed for purchasing, inspection and shipment coordination.
Can H05V-K be used for indicator lamps in switchgear?
From a specification standpoint, H05V-K has a clear use boundary that should not be stretched by marketing claims. The relevant search term is H05V-K indicator lamp wire. Yes, protected internal wiring for indicators and control devices can suit H05V-K when the circuit rating is appropriate. Lighting circuits outside the enclosure may need a different wiring system. GERITEL WIRE can confirm the requested size, colour, marking and packing details before production so the order matches the drawing.
Can H05V-K be used for control transformers inside panels?
For OEM wiring, the safest approach is to match the cable type to the actual circuit rather than choose by colour or flexibility alone. The relevant search term is H05V-K transformer control wire. It can be used on appropriate low-power internal transformer/control connections when current and temperature conditions are within limits. Transformer primary or secondary current may require a larger conductor or different cable type. For OEM projects, GERITEL WIRE can support technical data review, sample confirmation and practical reel or box packing.
Can H05V-K be used for contactor coil wiring?
The product can be a good fit, provided the voltage, cross-section and protected-installation conditions are correct. The relevant search term is H05V-K contactor wire. Yes, contactor coil and control-circuit connections are typical fixed panel applications for flexible single cores. Keep separation and overcurrent protection consistent with the control design. GERITEL WIRE can help compare the requested construction with the project specification before quotation, reducing avoidable model mismatches.

 

Hot Tags: h05v-k 0.5 mm² control panel wire flexible conductor for protected internal wiring, China h05v-k 0.5 mm² control panel wire flexible conductor for protected internal wiring manufacturers, suppliers, factory, HO5V-K

Send Inquiry