185 Mm² H07V-K Industrial Cable For Power Cabinets And Earthing

185 Mm² H07V-K Industrial Cable For Power Cabinets And Earthing
Details:
·Conductor: Class 5 flexible copper conductor
·Insulation: PVC (Polyvinyl Chloride)
·Voltage Rating Uo/U: H05V-K:300/500V ; H07V-K:450/750V
·Temperature Rating: Fixed: -30°C to +70℃ ; Flexed: -5°C to +70℃
·Standards: EN 50525-2-31, EN 60228 ; Flame Retardant according to IEC/EN 60332-1-2 ; UV Resistant
Send Inquiry
Download
Description
Technical Parameters
Certification

H07V-K 185mm2 cable

PRODUCT REAL SHOT

 

H07V-K 185 mm2 wire
H07V-K 185mm2 cable
185mm2 H07V-K cable

185 sq mm H07V-K wire

Flexible 185 mm² Copper Cable for Heavy Equipment Grounding and Connections
H07V-K in 185 mm² can be considered for specialised industrial cabinets where a large protected conductor is needed for suitable power, bonding or earthing duties. As 185 mm² industrial power cabinet wire, its Class 5 copper construction can make positioning and termination easier inside equipment compared with more rigid alternatives. It may also serve as heavy equipment earth cable when the protective-conductor design requires this cross-section and compatible lugs are available. GERITEL WIRE can support project marking, packaging and technical review before production. A large flexible terminal conductor must be selected from actual current, fault duty, bend space, terminal capacity and installation requirements rather than by size alone.
PRODUCT SPECIFICATIONS

 

2491X H07V-K 185mm2 cable

Applications

 

PVC panel wiring for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.

SPECIFICATIONS
Voltage Rating Uo/U

H05V-K:300/500V

H07V-K:450/750V

Temperature Rating

Fixed: -30°C to +70°C

Flexed: -5°C to +70°C

Minimum Bending Radius Fixed: 6 x overall diameter
Conductor Class 5 flexible copper conductor
Insulation PVC (Polyvinyl Chloride)
Insulation Colour Red,Black,Blue,Orange,Yellow,White,Green/Yellow,Violet,Pink,Grey,Brown
STANDARDS

EN 50525-2-31,EN 60228

Flame Retardant according to IEC/EN 60332-1-2

UV Resistant

DIMENSIONS

NOMINAL CROSS SECTIONAL AREA

mm²

NOMINAL OVERALL DIAMETER

mm²

NOMINAL WEIGHT

kg/km

H05V-K
0.5 2.20 9.1
0.75 2.40 11.7
1 2.55 14.4
H07V-K
1.5 3.00 20.1
2.5 3.65 31.5
4 4.20 46.2
6 4.80 65.1
10 6.25 109.4
16 7.40 165.2
25 9.40 253.4
35 10.40 345.5
50 12.55 492.4
70 14.10 669.3
95 17.20 910.4
120 17.70 1129.4
150 19.60 1401.0
185 23.00 1741.0
240 26.40 2267.5

CONDUCTORS

NOMINAL CROSS

SECTIONAL AREA

mm²

MAXIMUM DIAMETER

OF WIRES IN CONDUCTOR

mm

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Plain Wires
0.5 0.21 39
0.75 0.21 26
1 0.21 19.5
1.5 0.26 13.3
2.5 0.26 7.98
4 0.31 4.95
6 0.31 3.3
10 0.41 1.91
16 0.41 1.21
25 0.41 0.78
35 0.41 0.554
50 0.41 0.386
70 0.51 0.272
95 0.51 0.206
120 0.51 0.161
150 0.51 0.129
185 0.51 0.106
240 0.51 0.0801

ELECTRICAL CHARACTERISTICS

NOMINAL CROSSS

ECTIONAL AREA

mm²

REFERENCE METHOD A

(ENCLOSED IN

CONDUIT IN THERMALLY

INSULATING WALL ETC)

Amps

REFERENCE METHOD B

(ENCLOSED IN CONDUIT

IN WALL OR IN

TRUNKING ETC)
Amps

REFERENCE METHOD C

(CLIPPED DIRECT)
Amps

REFERENCE METHOD F

(IN FREE AIR OR ONA PERFORATED CABLE TRAY ETC HORIZONTAL OR VERTICAL ETC)

Amps

Touching

Spaced by

one diameter

2 Cables Single-Phase ACor DC or3 Cables Three-Phase AC flat

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

AC or DC

3 or 4Cables

Three-Phase

AC

2Cables

SinglePhase

AC or DCflat

3Cables

Three-Phase

ACflat

3 Cables

Three-Phase

ACtrefoil

Horizontal Vertical
1.5 14.5 13.5 17.5 15.5 20 18 - - - - -
2.5 20 18 24 21 27 25 - - - - -
4 26 24 32 28 37 33 - - - - -
6 34 31 41 36 47 43 - - - - -
10 46 42 57 50 65 59 - - - - -
16 61 56 76 68 87 79 - - - - -
25 80 73 101 89 114 104 131 114 110 146 130
35 99 89 125 110 141 129 162 143 137 181 162
50 119 108 151 134 182 167 196 174 167 219 192
70 151 136 192 171 234 214 251 225 216 281 254
95 182 164 232 207 284 261 304 275 264 341 311
120 210 188 269 239 330 303 352 321 308 396 362
150 240 216 300 262 381 349 406 372 356 456 419
185 273 245 341 296 436 400 463 427 409 521 480
240 321 286 400 346 515 472 546 507 485 615 569
CERTIFICATIONS

 

2491X 185mm2 cable

H07VK 185mm2 wire

PACKAGING

 

185mm2 flexible panel wire

Roll

07V-K 185mm2 cable

Plastic Reel

185mm2 panel wire

Small Wooden Reel

APPLICATION

 

185mm2 single core flexible cable
Industrial Control Panel
185mm2 PVC single core wire
Renewable Energy Power Connection
185mm2 Class 5 flexible wire

Switchboard Wiring

 

CASE

 

185mm2 flexible copper wire

Adelaide Airport Switchboard Upgrade

185mm2 control cabinet wire

Industrial Main Switchboard Power Distribution

185mm2 equipment wire

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

185mm2 450/750V flexible cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

H07V-K 185mm2 datasheet
 
H07V-K 185mm2 current rating
 
H07V-K 185mm2 amp rating
 
H07V-K 185mm2 current carrying capacity
 
H07V-K 185mm2 conductor resistance
 
H07V-K 185mm2 cable diameter
 
GLOBAL CERTIFICATIONS

 

EN 50525-2-31 185mm2 cable

CUSTOMER PHOTOS
 

IEC 60228 Class 5 185mm2 wire

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

H07V-K 185mm2 technical specification
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

185mm2 switchboard internal wiring cable
185mm2 distribution board flexible cable
185mm2 control panel power cable
185mm2 equipment power wiring cable
185mm2 flexible earth wire
185mm2 grounding cable
185mm2 equipotential bonding cable
185mm2 switchgear earth wire
185mm2 data center earthing cable
185mm2 energy storage cabinet cable
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

185mm2 industrial earthing cable
FAQ

 

Can H07V-K be used in a PV monitoring cabinet?
H07V-K can be used as PV monitoring cabinet wire for suitable internal power and control connections that do not require screening. Communication links should use the specified data or screened cable. GERITEL WIRE supports technical clarification and sample confirmation, which is useful when a panel builder needs to verify stripping, routing or terminal compatibility before a bulk order.
Can H07V-K be used inside a solar combiner box?
H07V-K may be used as solar combiner control wire for suitable protected auxiliary circuits, but it should not automatically replace the PV conductors carrying array DC current from modules. For distributors, GERITEL WIRE can plan repeat supply by colour and packaging format so warehouse stock is easier to manage across different customer applications.
Can H07V-K connect a solar panel to an inverter?
For exposed photovoltaic DC routing, use a dedicated solar panel connection cable approved for PV service. H07V-K is better reserved for protected internal wiring inside suitable electrical equipment. GERITEL WIRE applies incoming-material and finished-product quality controls and can discuss available inspection records or project documentation for the ordered construction.
Can H07V-K be used for inverter relay wiring?
H07V-K works well as inverter relay wire for suitable fixed internal connections. Check control voltage, enclosure temperature and terminal design, especially in high-power inverters with elevated internal temperatures. Where certification matters, GERITEL WIRE can check the exact certificate scope for the ordered product instead of relying on a general brand-level approval claim.

 

Hot Tags: 185 mm² h07v-k industrial cable for power cabinets and earthing, China 185 mm² h07v-k industrial cable for power cabinets and earthing manufacturers, suppliers, factory, HO7V-K

Send Inquiry