Solar PV Cable 4mm

Solar PV Cable 4mm
Details:
• Strong weather resistance, suitable for harsh outdoor environments
• TUV/UL/IEC/CE certification & more than 25 years life
• Large PV power stations/Rooftops/Floating solar stations/Farms
• Successfully connected 26GW power
• Comply with global standards
• PV cable manufacturers with 30+ years of production experience
• Quick online quotes & free samples are available
Send Inquiry
Download
Description
Technical Parameters
Certification
Solar PV Cable 4mm

 

Solar PV Cable 4mm
  • Certification: TUV/UL
  • Standard: IEC 62930 / EN 50618:2014
  • Conductor: Class 5 (flexible) tinned copper, based on EN 60228 and IEC 60228
  • Insulation & Sheath Jacket: Cross-Linked Polyolefin
  • Rated voltage: DC 1500V (between conductors and between conductor and earth), AC Uo/U: 1.0/1.0 KV
  • Application Class: A
  • Protection Class: II
  • Water performance: AD7
  • Test voltage: 6500V, 50Hz, 10Min
  • Fire Performance: Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1
  • Temperature Rating -40℃-90℃
  • The Max.Temperature: 120℃
  • Certification TUV/UL
  • No.of Conductor: Single Core / Twin Core

 

Application

 

 

Photovoltaic solar h1z2z2-k cable is an indispensable key component in the photovoltaic system. It mainly connects solar panels with inverters, junction boxes or control equipment, efficiently transmits DC power, and ensures the stable operation of the entire system.

4mm solar pv cable is particularly suitable for medium-power rooftop photovoltaic systems, home solar systems, and small commercial solar installations due to its excellent conductivity and moderate size. It uses cross-linked polyolefin (XLPE) insulation and sheath, with excellent high temperature resistance, UV resistance, ozone resistance, moisture resistance and mechanical strength, and can operate stably for a long time even in extreme outdoor environments. In addition, the cable also has flame retardancy and low smoke emission characteristics, which improves the overall safety of the system and is particularly suitable for installation environments that require a high level of safety. Its flexible structure also facilitates on-site wiring and maintenance.

4mm solar pv cable application

 

Feature

 

solar pv cable 4mm

 

4mm solar pv cable refers to a specific specification of photovoltaic cable, where 4mm² / 6mm2 refers to the cross-sectional area of the cable conductor being 4 square millimeters / 6 square millimeters. This type of cable is commonly used in photovoltaic systems to connect photovoltaic modules and inverters or to connect the DC and AC sides of photovoltaic systems. The design of photovoltaic cables takes into account weather resistance, UV resistance, and good insulation performance, making them suitable for outdoor use.

 

Certification

 

 

Solar PV cable 4mm has successfully passed TUV and UL certification. The TUV certification number is No. B 126326 0001 Rev.00. The cable complies with relevant standards such as EN 50618 and can operate stably and long-term in harsh environments.

At the same time, the UL certification number is UL-US-2561141-0. Photovoltaic cable also meets the strict requirements of the North American market for electrical performance, fire retardancy, and weather resistance, and is suitable for a variety of solar power generation projects, whether residential, commercial, or industrial applications.

All certification information can be directly verified on the official websites of TUV and UL, which are transparent and reliable. Choosing us means choosing quality-assured and internationally recognized PV cable suppliers.

4mm solar pv cable certification

 

Package

 

solar cable package

 

Production Line

 

china solar ac cable manufacturer

 

As a wholesale photovoltaic solar h1z2z2-k cable supplier, Greater Wire has more than 30 years of experience in production experience. Our factory is equipped with advanced extrusion equipment, automated wire cutting systems, and strict quality inspection process to ensure that every meter of cable meets international standards.

H1z2z2-k solar cable has not only passed multiple international certifications such as TUV, CE, UL, but also complies with IEC 62930 and EN 50618 standards. It is suitable for various high-efficiency solar systems and has excellent UV resistance, high temperature resistance, corrosion resistance, and adaptability to extreme outdoor environments.

We also support OEM services and can provide different specifications, colors, packaging, and labels according to customer needs to meet the personalized needs of project installation. We have successfully exported to more than 80 countries and regions around the world, and widely serve large-scale photovoltaic power stations, residential roofs, commercial roof,s and mobile energy storage systems.

 

Case

 

pv cable suppliers

 

Partner

 

Greater Wire Partner

 

FAQ

 

Q: Can I use 4mm cable for solar panels?

A: Yes, you can use 4mm² (square millimeters) cable for solar panels, but there are important factors to consider:Current Rating: Ensure that the 4mm² cable can handle the maximum current output of your solar panels. The current rating for a 4mm² cable can vary depending on the type of cable and installation conditions, but it generally ranges between 25 to 30 amps. Check the specifications of both your solar panels and the cable to make sure they are compatible.

Q: How many amps can a 4mm solar cable handle?

A: The ampacity of a 4mm² solar cable depends on several factors, including the type of cable, insulation, and installation conditions. Generally, for solar PV applications, a 4mm² cable can handle around 25 to 30 amps.

Q: What is the difference between 4mm and 6mm solar cable?

A:The primary differences between 4mm² and 6mm² solar cables are related to their current-carrying capacity, voltage drop, and physical size. Here's a breakdown of the key differences:

Current Carrying Capacity:

4mm² Cable: Typically handles around 25 to 30 amps.

6mm² Cable: Generally supports around 35 to 45 amps.

Voltage Drop:

4mm² Cable: Higher voltage drop over long distances compared to a 6mm² cable. This can lead to inefficiencies in power transmission.

6mm² Cable: Lower voltage drop, which means better efficiency in

Physical Size and Flexibility:

4mm² Cable: Thinner and more flexible, making it easier to handle and install, especially in tight spaces or complex configurations.

6mm² Cable: Thicker and less flexible, which might make it a bit more challenging to work with, but it offers better performance in terms of current capacity and voltage drop.

Q: Can I use 6mm solar pv cable instead of 4mm?

 
A: Yes, you can use 6mm solar cable instead of 4mm pv cable, but the 4mm solar cable can not instead of 6mm solar cable.

 

 

Hot Tags: Solar PV Cable 4mm, China Solar PV Cable 4mm manufacturers, suppliers, factory, tuv solar cable, SAA Approval SDI Cable, SAA Orange Circular Cable, SAA Australia Flat 2C E Electrical TPS Cable, nmd90, rubber cable

4mm pv cable

Conductor Nominal Insulation Thickness
(mm)
Nominal sheath Thickness
(mm)
Approx. Overall Diam.(mm) Approx.
Weight (kg/km)
Minimum Insulation Max.Conductor Resistance DC @20'C(MΩ.km)
Nominal Area(mm2) Approx.
Diam.
(mm)
20°C(MΩ.km) 90°C(MΩ.km)
1x1.5 1.57 0.7 0.8 4.7 38 860 0.86 13.7
1x2.5 2.04 0.7 0.8 5.2 45 690 0.69 8.21
1x4 2.6 0.7 0.8 5.6 60 580 0.58 5.09

1x6

3.16

0.7

0.8 6.3 90 500 0.50 3.39
1x10 4.5 0.7 0.8 7.6 131 420 0.42 1.95
1x16 5.7 0.7 0.9 9.0 187 340 0.34 1.24
1x25 7.2 0.9 1.0 11.2 267 340 0.34 0.795
1x35 8.5 0.9 1.1 12.7 368 290 0.29 0.565
1x50 9.4 1.0 1.2 14.5 560 270 0.27 0.393
1x70 11.1 1.1 1.2 16.5 756 250 0.25 0.277
1x95 13.1 1.1 1.3 18.7 1036 220 0.22 0.210
1x120 14.8 1.2 1.3 20.4 1309 210 0.21 0.164
1x150 16.5 1.4 1.4 22.7 1636 210 0.21 0.132
1x185 18.3 1.6 1.6 25.2 2000 200 0.20 0.108
1x240 21.0 1.7 1.7 28.5 2607 200 0.20 0.0817
2x1.5 1.57 0.7 0.8 4.8*10.5 78 860 0.86 13.7
2x2.5 2.04 0.7 0.8 5.2*11.8 92 690 0.69 8.21
2x4 2.6 0.7 0.8 5.6*12.8 122 580 0.58 5.09
2x6 3.16 0.7 0.8 6.3*13.7 182 500 0.50 3.39
2x10 4.5 0.7 0.8 8.0*16.8 264 420 0.42 1.95
2x16 5.7 0.7 0.9 9.0*19.8 376 340 0.34 1.24

 

tuv solar cable certification

Send Inquiry