·Conductor: Flexible bunched annealed copper conductor to AS/NZS 1125 (Class 5)
·Insulation: V-90 PVC
·Colour: Green/yellow
·Approvals: Suitable for fixed applications only in accordance with AS/NZS 3000 +AS/NZS 5000.1
·Maximum operating temperature: +90℃
·Minimum operating temperature: 0℃
Send Inquiry
Download
Description
Technical Parameters
Certification

10mm flexible earth cable

PRODUCT REAL SHOT

 

10mm2 flexible earth cable
10 mm2 flexible earth cable
10 sq mm flexible earth cable

10mm green yellow earth cable

Class 5 Copper Protective Earth Conductor for MCC Systems
Built for secure grounding for higher-load equipment, this 10mm green yellow earth conductor uses fine-stranded annealed copper with V-90 PVC insulation and green/yellow identification. Rated 0.6/1 kV, it supports protective earthing and bonding in motor control centres and generators. Flexible construction eases routing through ducts, bends and crowded terminals while helping installers form neat, secure connections. Specify the MCC grounding cable when a dependable V90 PVC flexible PE wire is needed for fixed electrical installations rather than continuous motion. Supplied in cut lengths or drums, the industrial bonding conductor can support OEM, switchboard and project orders.
PRODUCT SPECIFICATIONS

 

10mm green yellow flexible cable

Cable description

 

Flexible PVC insulated only earth cable to AS/NZS 5000.1

Applications

 

For use as protective earth in electrical installations. For use where improved aging properties to those of 75°C PVC are required because of higher ambient temperatures. Suitable for glanding.

SPECIFICATIONS
Approvals Suitable for fixed applications only in accordance with AS/NZS 3000 +AS/NZS 5000.1
Behaviour in flame and fire Flame propagation=AS/NZS 1660.5.6
Temperature range

Maximum operating temperature: +90°C

Minimum operating temperature: 0 °C

Minimum bending radius

Installed cables: 4D

During installation: 6D

Resistance to

Chemical exposure: Occasional

Mechanical impact: Light

Water exposure:  Occasional condensation

Solar radiation and weather exposure: Occasional

Cable design

Conductor: Flexible bunched annealed copper conductor to AS/NZS 1125 (Class 5)

Insulation: V-90 PVC

Colour: Green/yellow

Installation conditions

Industrial equipment

In conduit

Machines

Internal wiring

 For fixed installation

Conductor

Cable

Min.

installed

bending

radius

mm

Nominal

C.S.A

mm²

Nominal

diameter
mm

Nominal

nsulation

thickness

mm

Overall diameter

Approx.

mass

kg/100 m

Minimum

mm

Maximum

mm

1.0 1.3 0.8 2..9 3.0 1.6 12
1.5 1.5 0.8 3.1 3.2 2.0 13
2.5 2.0 0.8 3.6 3.7 3.0 15
4 2.7 1.0 4.6 4.7 5.4 19
6 3.5 1.0 5.4 5.6 8.0 22
10 4.2 1.0 6.1 6.3 11 25
16 5.3 1.0 7.2 7.4 16 30
25 6.7 1.2 8.9 9.1 25 40
35 7.9 1.2 10.1 10.3 34 45
50 9.5 1.4 12.1 12.3 49 50
70 11.3 1.4 13.9 14.2 67 60
95 13.0 1.6 16.0 16.2 89 65
120 14.7 1.6 17.6 17.9 112 75
150 16.5 1.8 19.8 20.2 140 85
185 18.2 2.0 21.9 22.2 170 90
240 20.9 2.2 25 25.4 223 105
300 23.5 2.4 27.9 28.4 279 115
400 26.9 2.6 31.7 32.2 365 130

Electrical characteristics

Conductor

nominal

C.S.A.

mm²

MaximumD.C.

resistance

at 20°C

Ω/km

Reactance per core

(Trefoil, Touching)

Ω/km

1.0 19.5 0.116
1.5 13.3 0.109
2.5 7.98 1.101
4 4.95 0.100
6 3.30 0.0954
10 1.91 0.0876
16 1.21 0.0835
25 0.780 0.0829
35 0.554 0.0801
50 0.386 0.0799
70 0.272 0.0773
95 0.206 0.0771
120 0.161 0.0753
150 0.129 0.0755
185 0.106 0.0754
240 0.0801 0.0749
300 0.0641 0.0747
400 0.0486 0.0738
CERTIFICATIONS

 

10mm flexible grounding cable

10mm flexible ground wire

PACKAGING

 

10mm 0.6/1kV flexible cable

Roll

10mm 600/1000V flexible cable

Plastic Reel

10mm single core flexible earth cable

Small Wooden Reel

APPLICATION

 

1C 10mm flexible earth cable
Industrial Control Panel
10mm V90 PVC earth cable
Renewable Energy Power Connection
10mm Class 5 copper earth cable

Switchboard Wiring

 

CASE

 

10mm flexible protective earth conductor

Adelaide Airport Switchboard Upgrade

10mm AS/NZS 5000.1 earth cable

Industrial Main Switchboard Power Distribution

4D bending radius flexible cable

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

6D installation bending radius cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

fine wire stranded earth cable
 
multiple stranded earth cable
 
plain annealed copper ground cable
 
PVC V90 insulated ground wire
 
flexible earth cable 90C rating
 
flexible earth cable conductor resistance
 
GLOBAL CERTIFICATIONS

 

flexible earth cable cable diameter

CUSTOMER PHOTOS
 

flexible earth cable insulation thickness

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

flexible earth cable weight per 100m
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

flexible earth cable nominal CSA
flexible earth cable cross sectional area
flexible earth cable voltage drop
flexible earth cable reactance
flexible earth cable for glanding
flexible cable fixed installation
flexible cable in conduit
flexible cable enclosed wiring
flexible cable occasional condensation
flexible cable light mechanical impact
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

green yellow cable identification
FAQ

 

Can it be used as a main earthing conductor?
It may be suitable, but the cross-sectional area must be selected from the earthing design, prospective fault current, disconnection time and installation method. The cable is suitable for fixed applications under AS/NZS 3000 and is suitable for glanding. GERITEL WIRE can prepare a technical submittal based on the confirmed project specification. Relevant product terms are 0.6/1kV green yellow flexible earth cable, Class 5 copper protective earth conductor and V-90 PVC earth cable.
Is 'grounding cable' an acceptable name for this product?
Yes. 'Grounding cable' is widely understood internationally, while 'protective earth cable' is the more precise term for Australian and New Zealand projects. The confirmed operating range is 0°C to +90°C. GERITEL WIRE supports mixed-size project orders and can identify the correct SAA certificate by conductor size. Relevant product terms are 0.6/1kV green yellow flexible earth cable, Class 5 copper protective earth conductor and V-90 PVC earth cable.
Can this cable be used in temporary electrical installations?
Only where the completed cable installation remains fixed and protected. It is not a portable cord, trailing cable or repeated-flexing product. Flame propagation is assessed to AS/NZS 1660.5.6. GERITEL WIRE can provide production records and inspection information for project review. Relevant product terms are 0.6/1kV green yellow flexible earth cable, Class 5 copper protective earth conductor and V-90 PVC earth cable.
Does 'flexible' mean the cable can move continuously?
No. 'Flexible' describes the fine-stranded conductor and installation handling; the approved duty is fixed application only. SAA certification is split between SAA241316 and SAA241317 according to conductor size. GERITEL WIRE can help compare the standard product with alternative constructions for harsher environments. Relevant product terms are 0.6/1kV green yellow flexible earth cable, Class 5 copper protective earth conductor and V-90 PVC earth cable.

 

Hot Tags: 10mm flexible ground cable 600/1000v single core v90, China 10mm flexible ground cable 600/1000v single core v90 manufacturers, suppliers, factory

Send Inquiry