1.50mm 2 Core TPS Fire Alarm Cable

1.50mm 2 Core TPS Fire Alarm Cable
Details:
100% pure copper conductor, V-90 PVC insulation, 3V-90 PVC sheath, temperature resistance of 90 ℃
PVC outer jacket provides mechanical protection to prevent the cable from external damage
Flat design for easy wiring and installation
SAA certified, long service life
More than 20 years of production experience
Quick online quote & free samples available
Send Inquiry
Download
Description
Technical Parameters
Certification
 TPS Fire Alarm Cable GREATER / GERITEL WIRE

 

 
1.50mm 2 Core TPS Fire Alarm Cable

TPS Fire Alarm Cable is a cable specifically designed for fire alarm systems, mainly used to provide reliable electrical connections and signal transmission in the event of a fire. The main feature of TPS Fire Alarm Cable is its ability to resist fire and the spread of fire, which can maintain its function in a fire environment, ensure that the fire alarm system can continue to operate, and provide timely fire warnings.The commonly used models of TPS Fire Alarm Cable are:1.50mm 2 Core TPS Fire Alarm Cable,Flat White Stripe TPS Fire Alarm Cable 0.75mm 2 Core,Flat White Stripe TPS Fire Alarm Cable 1.00mm 2 Core

 

 

 

 

Application

 

 


The main application of 1.50mm 2 Core TPS Fire Alarm Cable in fire alarm systems is as signal transmission lines. 1.50mm 2 Core TPS Fire Alarm Cable connects fire detectors, control panels, sound and light alarm devices, and other equipment to ensure timely transmission of alarm signals and issuance of warnings in the event of a fire. Specifically, it includes:1.50mm 2 Core TPS Fire Alarm Cable is used to connect smoke detectors and temperature detectors to alarm controllers.
1.50mm 2 Core TPS Fire Alarm Cable is also used for signal transmission between fire alarm control panels and alarm devices.  1.50mm 2 Core TPS Fire Alarm Cable are used to connect emergency lighting equipment to power sources, ensuring their proper functioning in the event of a fire or power outage and aiding in the rapid evacuation of personnel.

flat cable application

 

Feature

 

 TPS Fire Alarm Cable GREATER / GERITEL WIRE

 

● Double insulated red outer sheath marked as "fire alarm cable"

● ActivFire certified
● Best Environmental Practice PVC v 2.0 certified - Bureau Veritas
● 250/250V voltage rating
● Sheath:3V-90 PVC
● Red and white cores
● Normal Operating Temperature: +90°c
● Minimum Operating Temperature: 0°c
● ELV/LV markings as per AS/NZS 1670:2018
● WSX1 Mechanical protection to AS/NZS 3013 & complying with AS1670.1.2018
● AS/CA S008 compliant

●Independently certified & licensed to meet Green Building Code of Australia / Green Star requirements
● Certification: SAA

 

Certification

 

1.50mm 2 Core TPS Fire Alarm Cable have passed the Australian SAA certification and comply with the AS/NZS 5000.2 standard,
This is a standard for building electrical wiring and cable products, including specifications applicable to low-voltage power and control cables. For fire alarm cables, it specifies the requirements for the conductor, insulation material, outer sheath, and overall structure of the TPS Fire Alarm Cable.

1.50mm 2 Core TPS Fire Alarm Cable also comply with the requirements of AS 3013,This standard defines the requirements for cables used in fire protection and fire alarm systems, particularly with regards to their fire resistance, structure, and identification. TPS fire alarm cable must comply with the fire resistance standards in AS:3013 to ensure that they can continue to transmit signals and maintain their functionality in the event of a fire.

TPS cable certification

 

Package

 

Our 1.50mm 2 Core TPS Fire Alarm Cable packaging standard is 100 meters per roll, packaged with rubber trays, and the 1.50mm 2 Core TPS Fire Alarm Cable stacked on a pallet every 180 rolls. In general, a 20FT container can hold 10 pallets 1.50mm 2 Core TPS Fire Alarm Cable, which is 1800 rolls of 1.50mm 2 Core TPS Fire Alarm Cable. We can also package according to customer requirements, such as 200 meters per roll or 500 meters per roll, but we have minimum order quantity requirements for different tps electrical cable.

 

542d121aa2111e217c472e349cf6a631111333323

 

Production Line

 

SAA cable factory

 

Greater Wire Company focuses on producing high-quality TPS Fire Alarm Cable that meet Australian standards, aiming to provide reliable and safe cable solutions to meet the strict requirements of fire alarm systems for fire resistance, flame retardancy, and high performance. The factory adopts advanced production technology and strict quality control system to ensure that each TPS Fire Alarm Cable meets the certification standards of AS 3013, RCM, SAA, etc., and conforms to the usage standards in fire environments. Our TPS Fire Alarm Cable are widely used in important places such as commercial buildings, industrial facilities, and transportation hubs to ensure stable operation of fire alarm systems at critical moments and ensure personnel safety.

 

customer

 

As a professional electrical cable export manufacturer, my clients are located in various regions around the world, and we are familiar with the wire and cable standards of different countries. The main sales markets for TPS CABLE, orange circular cable are Australia, New Zealand, Papua New Guinea, and THHN wire,MC cable,nm b cable is mainly sold in American countries such as the United States and Canada. We not only have agents and electrical engineers in many countries, but also have a professional technical team to provide technical support.

 

09296990cd82752a230ea7e54bc7004111111

 

 

Partner

 

greater wire Partner

 

FAQ

 

 

 

 

Q: What is the outer material of the Australian TPS fire alarm cable?

A: 1.PVC (polyvinyl chloride V-90): PVC (V-90) material has good flame retardant properties, chemical corrosion resistance, and wear resistance. It can effectively prevent the spread of flames and ensure the continuous and stable operation of TPS fire alarm cable at high temperatures
     2.LSZH (Low Smoke Zero Halogen) Material:In some high demand places, theTPS fire alarm cable sheath may be made of LSZH material, which can release less toxic smoke and corrosive gases in case of fire, and is suitable for buildings with high environmental safety requirements, such as hospitals, subways, and airports

Q: Does the Australian TPS fire alarm cable comply with Australia's electrical safety standards?

A: Yes, the Australian standard TPS fire alarm cable must comply with the following Australian electrical safety standards: 1. AS/NZS 5000.2, which specifies the safety requirements for power and control cables and is applicable to low-voltage cable products, including tps fire alarm cable. The design and performance of cables must comply with the safety regulations of this standard to ensure that fires are not caused by electrical faults. 2. AS 3013,which is an Australian standard specifically designed for firefighting equipment and tps fire alarm cables. According to this standard, tps fire alarm cables need to have excellent fire resistance and flame retardancy, be able to maintain the functionality of the cable in the event of a fire, and ensure that signals can continue to be transmitted.

Q: What is the working voltage of TPS fire alarm cable?

A: The working voltage of TPS fire alarm cables is usually low voltage cables, and they are designed to connect equipment to fire alarm systems. General operating voltage: 1. Rated voltage: usually 300/500V (rated voltage of 300 volts or 500 volts), which means that the cable is designed to transmit low-voltage power and signals. 2. Maximum working voltage: The maximum working voltage of TPS fire alarm cable also does not exceed 600V, used for transmitting alarm signals and power.

 

 

Hot Tags: 1.50mm 2 core tps fire alarm cable, China 1.50mm 2 core tps fire alarm cable manufacturers, suppliers, factory, 0 6 1KV Single Core Building Cable, spt cable, mc cable, aerial parallel cable, AS NZS5000 1 Aerial Parallel Cable, USE 2 XHHW XHHW 2 XLPE Insulation Copper Wire

fire rated wire cable

1 Core (No Sheath)
No. of Cores Cross Section (mm2) Copper Wire Diameter (mm) Approx Overall Diameter (mm) Colour
1 1.5 0.52 3.9 White / Red
2 Core & 2 Core Comms
No. of Cores Cross Section (mm2) Copper Wire Diameter (mm) Approx Overall Diameter (mm) Drum Length
2 0.75 0.37 9.8 250m, 500m
2 1.00 0.42 10 250m, 500m
2 1.50 0.52 10.3 250m,500m
2 2.50 0.67 11.8 250m, 500m
2 4.00 0.85 13.7 Cut to length
2 6.00 1.04 16.2 Cut to length
3 Core
No. of Cores Cross Section (mm2) Copper Wire Diameter (mm) Approx Overall Diameter (mm) Drum Length
3 0.75 0.37 10.8 500m
4 Core
No. of Cores Cross Section (mm2) Copper Wire Diameter (mm) Approx Overall Diameter (mm) Drum Length
4 1.50 0.52 12 250m, 500m
4 Core Screened
No. of Cores Cross Section (mm2) Copper Wire Diameter (mm) Approx Overall Diameter (mm) Drum Length
4 1.50 0.52 13.8 500m

 

Send Inquiry