Industrial 1mm2 V90 PVC Flex Cable – Heavy Duty 0.6/1kV Cord

Industrial 1mm2 V90 PVC Flex Cable – Heavy Duty 0.6/1kV Cord
Details:
·Conductor: Annealed copper conductor
·Insulation: V-90 PVC (Polyvinyl chloride)
·Sheath: 5V-90 PVC (Polyvinyl chloride)
·Sheath Colour: Black,Orange
·Core Identification: 1 Core (choice) Red, White, Light Blue, Black 2 Cores: Brown, Light Blue 3 Cores: Brown, Light Blue, Green/Yellow 4 Cores: Brown,Light Blue, White, Green/Yellow 5 Cores: Brown, Light Blue,White,Orange,Green/Yellow
·STANDARDS: AS/NZS 5000.1, AS/NZS 3191, AS/NZS 1125
·Rated Voltage Uo/U:0.6/1kV
·Temperature Rating:Maximum continuous operating temperature: 90°C
·Minimum Bending Radius:Flexed: 6x Overall diameter
Send Inquiry
Download
Description
Technical Parameters
Certification

2 core 1mm² heavy duty flexible cord

PRODUCT REAL SHOT

 

2 core 1mm² heavy duty flexible cord
1mm2 2 core V90 flexible cable
2C x 1mm2 V90 PVC flex cable

2 x 1mm2 0.6/1kV flexible cable

Heavy Duty Extension Lead Cable for Equipment and Enclosed Power Connections
The 1.0mm² size is a practical starting point for heavier ordinary equipment leads, panel wiring and extension-lead applications where the finished assembly permits this construction. A 1mm2 industrial flexible cable offers easy handling with 2, 3, 4 or 5 core options grouped under one product link. The 0.6/1kV equipment power cord uses flexible annealed copper, V-90 PVC core insulation and a 5V-90 PVC outer sheath, with black or orange sheath options subject to order requirements
PRODUCT SPECIFICATIONS

 

2 core 1mm2 heavy duty flexible cable

Applications

 

Heavy Duty flexible cords for installation in switchboards and control panels especially in tight routes and confined spaces,and where flexibility is needed for hinged panels. Suitable for small industrial and commercial equipment requiring three-phase power. Can be used for extension leads in sizes 1mm² and above. 3 core and above include earth core for three-phase/single phase supply such as equipment with three-phase motor and single phase pilot lights like industrial sweepers, vacuum cleaners and welders. Also suitable for use with double insulated appliances where the cord is subject to higher mechanical stress, in damp and wet conditions.

SPECIFICATIONS
Rated Voltage Uo/U 0.6/1kV
Temperature Rating Maximum continuous operating temperature: 90°C
Minimum Bending Radius 6x overall diameter
Conductor Annealed copper conductor
Insulation V-90 PVC (Polyvinyl chloride)
Sheath 5V-90 PVC (Polyvinyl chloride)
Sheath Colour

Black, Orange

Core Identification

1 Core (choice) Red, White, Light Blue, Black

2 Cores: Brown, Light Blue

3 Cores: Brown, Light Blue, Green/Yellow

4 Cores: Brown,Light Blue, White, Green/Yellow

5 Cores: Brown, Light Blue,White,Orange,Green/Yellow

STANDARDS AS/NZS 5000.1, AS/NZS 3191, AS/NZS 1125
NO.OF CORES

NOMINALCONDUCTOR
SIZE

mm

NOMINAL

INSULATION

THICKNESS

mm

NOMINAL

OUTER SHEATH

THICKNESS

mm

NOMINAL

OVERALL

DIAMETER

mm

NOMINAL
WEIGHT
kg/100m
2 0.75 0.8 1.3 8.2 8.4
2 1.0 0.8 1.3 8.6 9.3
2 1.5 0.8 1.5 9.5 12
2 2.5 0.9 1.7 11.2 17
2 4 1.0 1.8 13 25
3 0.75 0.8 1.4 8.8 10
3 1.0 0.8 1.4 9.2 11
3 1.5 0.8 1.6 10.2 15
3 2.5 0.9 1.8 12.1 21
3 4 1.0 1.9 13.9 30
3 6 1.0 2.9 16.0 44
3 10 1.0 3.1 20.5 69
3 16 1.0 3.3 24.1 90
3 25 1.2 3.7 29.4 140
3 35 1.2 4.0 32.5 181
3 50 1.4 4.4 37.7 241
4 0.75 0.8 1.5 9.8 12
4 1.0 0.8 1.5 10.2 14
4 1.5 0.8 1.7 11.3 18
4 2.5 0.9 1.9 13.3 26
4 4 1.0 2.0 15.4 38
4 6 1.0 3.0 17.6 54
4 10 1.0 3.3 22.6 85
4 16 1.0 3.5 26.1 122
4 25 1.2 3.9 32.0 191
4 35 1.2 4.2 35.3 246
4 50 1.4 4.7 41.2 332
4 70 1.4 5.1 48.3 460
4 95 1.6 5.7 53.3 577
4 120 1.6 6.1 60.0 731
5 0.75 0.8 1.6 10.8 15
5 1.0 0.8 1.6 11.2 17
5 1.5 0.8 1.8 12.4 21
5 2.5 0.9 2.0 14.6 30
5 4 1.0 2.2 17.1 46

NOMINAL CONDUCTOR

SIZE
mm

CURRENT CARRYING

CAPACITY
A

MAXIMUM DC

RESSTANCE AT 20 °C

Ohm/km

MAXIMUM AC

RESISTANCE AT 90°C
Ohm/km

SINGLE PHASE

VOLTAGE DROP

MV/A.m

0.5 3 39.0 49.7 99.4
0.75 7.5 26.0 33.2 66.3
1.0 10 19.5 24.9 49.8
1.5 16 13.3 17 34
2.5 20 7.98 10.2 20.3
4.0 25 4.95 6.31 12.6
CERTIFICATIONS

 

2 core 1mm2 orange flexible cable

1mm2 2 core Class 5 flexible cable

PACKAGING

 

V90 2 core 0.75mm2 PVC flexible cable 0.6/1kV

Roll

1mm2 2 core Class 5 flexible cable

Plastic Reel

heavy duty flex cable

Small Wooden Reel

APPLICATION

 

heavy duty flexible cable
Control Panels & Switchboards
V90 2 core 1mm2 PVC flexible cable 0.6/1kV
Industrial Vacuum & Wet-Area Equipment
heavy duty power cord

Three-Phase Motor & Pump Equipment

 

CASE

 

heavy duty power cable

Bayswater Power Station Crane Drive System Upgrade

5 core 1mm² heavy duty flexible cord

Brewery Control System Upgrade

V90 heavy duty flexible cable

North Esk Irrigation Pump Station

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

5C x 1mm2 V90 PVC flex cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

4 core heavy duty flexible cable for three phase motor
 
heavy duty flexible cable for industrial sweeper
 
0.6/1kV flexible cable for industrial sweeper
 
PVC heavy duty flex cable for industrial sweeper
 
heavy duty flexible cable for industrial vacuum cleaner
 
V90 flexible cord for industrial vacuum cleaner
 
GLOBAL CERTIFICATIONS

 

heavy duty flexible cable for extension lead

CUSTOMER PHOTOS
 

heavy duty flexible cable for extension lead

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

PVC heavy duty flex cable for extension lead
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

what colours are used in heavy duty flexible cord cores
how many cores are needed for three phase flexible cable
how many cores are needed for three phase flexible cable
how many cores are needed for three phase flexible cable
is heavy duty flexible cable suitable for continuous flexing
can heavy duty flexible cord be used outdoors
can V90 heavy duty cable be used in wet areas
can heavy duty flexible cable be used for three phase motors
can heavy duty flexible cable be used for welders
can V90 flexible cable be used for extension leads
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

can heavy duty flexible cable be used in control panels
FAQ

 

Is Heavy Duty Flexible Cord suitable for industrial equipment?
Yes. Overseas V90 heavy-duty cord literature specifically lists small industrial and commercial equipment, motors, welders and similar equipment among typical applications. GERITEL WIRE can supply Industrial Flexible Power Cable options with different conductor sizes and core counts, and can help buyers confirm whether the load, number of phases, earth requirement and installation environment match the selected cable before production.
Is this cable rated for 0.6/1kV?
Yes, Heavy Duty V90 flexible cords in this product family are commonly rated Uo/U 0.6/1kV. GERITEL WIRE can provide the applicable specification and compliance documents for the ordered 0.6/1kV Flexible Cable, helping the buyer verify that the voltage marking, core count and conductor size on the quotation match the product being supplied. Final use should still follow the destination market's electrical rules.
What does V90 mean on this cable?
V-90 identifies the PVC insulation temperature class used in the cable construction. It should not be interpreted as permission to operate every installation at 90°C regardless of current, enclosure temperature or installation method. GERITEL WIRE can provide the construction and relevant technical data for a V90 Heavy Duty Flexible Cable so engineers can apply the correct current-rating and derating rules for the actual circuit.
What does 5V-90 mean on the sheath?
5V-90 is a PVC sheath compound designation used on many Australian/New Zealand heavy-duty flexible cord constructions. It serves a different role from the V-90 insulation around each conductor. GERITEL WIRE can clearly identify the insulation and sheath layers of a 5V-90 PVC Sheathed Flexible Cable in technical documentation, which helps customers avoid confusing two different PVC material designations during specification review.

 

Hot Tags: industrial 1mm2 v90 pvc flex cable – heavy duty 0.6/1kv cord, China industrial 1mm2 v90 pvc flex cable – heavy duty 0.6/1kv cord manufacturers, suppliers, factory