SAA certified screened pairs shielded instrument cable is designed for precision signal transmission in high-interference areas in industrial environments, ensuring the accuracy and integrity of signals in process control systems. The product uses annealed bare copper conductors that meet AS/NZS 1125 standards, with good conductivity and mechanical flexibility; each pair of cores uses V-90 RP PVC insulation (in compliance with AS/NZS 3808 standards), and the twisted structure effectively suppresses crosstalk.
Application
Screened pairs shielded instrument cable have passed SAA certification and fully complies with Australia/New Zealand's strict requirements for electrical safety, fire resistance, and long-term operation stability of cables. SAA certification is an important safety access mark for entering the Australian market, and it means that the product has reached the industry's high standards in material selection, structural design, and performance testing.

Certification
Screened Pairs Shielded Instrument Cable has passed SAA certification and fully complies with Australia/New Zealand's strict requirements for electrical safety, fire resistance, and long-term operation stability of cables. SAA certification is an important safety accreditation mark for entering the Australian market, and it means that the product has reached the industry's high standards in material selection, structural design, and performance testing.

Package

Company Introduction

Greater Wire is a company specializing in high-performance Instrumentation Cable. The cables are manufactured in strict accordance with international standards such as IEC, BS, AS/NZS, UL, etc., and have passed authoritative certifications such as UL, CE, SAA, TUV, and RoHS. The company is equipped with advanced extrusion, twisting, shielding, and testing equipment, and has established a complete quality management system and laboratory testing process. Each batch of products is stable and reliable in terms of signal integrity, electrical performance, and mechanical strength.
Whether in high electromagnetic interference areas or hazardous places such as oil and gas platforms, chemical pipelines, water treatment plants, etc., Greater Wire's instrumentation cables can ensure accurate signal transmission and are customers' preferred partners in system integration, engineering projects, and global procurement.
customer

Partner

FAQ
Q: What type of cable is an instrument cable?
Q: Is a TS cable an instrument cable?
In the industrial context, instrumentation cables refer to shielded, multi-pair cables used to transmit signals from sensors to control systems, totally different in purpose and design.
Hot Tags: screened pairs shielded instrument cable, China screened pairs shielded instrument cable manufacturers, suppliers, factory

| Pairs | Nominal overall diameter |
Mininum bending radius |
Maximum pulling tension |
Approx. mass |
| mm | mm | kN | kg/100m | |
| Conductor 0.5mm² (7/0.30mm) | ||||
| 1 | 5.2 | 31 | 0.07 | 3.5 |
| 2 | 7.8 | 47 | 0.14 | 6.3 |
| 4 | 8.4 | 50 | 0.28 | 9.4 |
| 6 | 10 | 60 | 0.42 | 13 |
| 8 | 11.2 | 67 | 0.56 | 17 |
| 10 | 12.5 | 75 | 0.7 | 21 |
| 12 | 13.4 | 80 | 0.84 | 24 |
| 16 | 15.1 | 91 | 1.12 | 31 |
| 20 | 16.8 | 101 | 1.4 | 38 |
| 24 | 18.1 | 109 | 1.68 | 45 |
| 36 | 22 | 132 | 2.52 | 66 |
| 50 | 25.6 | 153 | 3.5 | 90 |
| Conductor 1.5mm²(7/0.50mm) | ||||
| 1 | 6.6 | 40 | 0.21 | 6 |
| 2 | 9.9 | 60 | 0.42 | 11 |
| 4 | 10.9 | 65 | 0.84 | 18 |
| 6 | 13 | 78 | 1.26 | 26 |
| 8 | 14.6 | 88 | 1.68 | 33 |
| 10 | 16.3 | 98 | 2.1 | 41 |
| 12 | 17.5 | 105 | 2.52 | 48 |
| 16 | 20 | 120 | 3.36 | 63 |
| 20 | 22.3 | 134 | 4.2 | 79 |
| 24 | 24.1 | 145 | 5.04 | 93 |
| 36 | 29.2 | 175 | 7.56 | 137 |
| 50 | 34.2 | 205 | 10.5 | 188 |