10mm Two Core TPS Flat Feeder Cable

10mm Two Core TPS Flat Feeder Cable
Details:
·Insulation: V-90 PVC
·Sheath: 3V-90 PVC
·APPROVALS: AS/NZS 5000.2
·Normal operating temperature: +90℃
·Minimum operating temperature: 0℃
Send Inquiry
Download
Description
Technical Parameters
Certification

10mm TPS twin core cable

PRODUCT REAL SHOT

 

16mm2 flat TPS cable
16 mm² white TPS cable
16mm PVC flat cable

16mm 3 core and earth cable

10 mm² Plain Annealed Copper Building Cable for Modular Projects
The 10mm Two Core TPS Flat Feeder Cable is a higher-capacity option for engineered fixed feeders, submains and dedicated circuits requiring two working conductors without an integral protective-earth core. Plain annealed copper conductors to AS/NZS 1125 are protected by V-90 PVC insulation and a white 3V-90 PVC flat sheath. Manufactured to AS/NZS 5000.2 for 450/750V applications, it may be evaluated as Flat Twin Cable for Factory Built Home Submains, Two Core Building Cable for Modular Accommodation Feeders or 10 mm² TPS Cable for Commercial Building Services. GERITEL WIRE supports project schedules, custom reel lengths, printed identification and inspection documentation; final sizing requires load and voltage-drop calculations.
PRODUCT SPECIFICATIONS

 

10mm2 flat twin core cable

Applications

 

For general wiring, unenclosed, enclosed in conduit,for domestic, commercial and industrial installations where not subject to mechanical damage.

SPECIFICATIONS
Cable description PVC insulated laid flat and PVC sheathed cableto A5/NZ5 5000.2
Approvals A5/NZS5000.2
Behaviour in flame and fire Flame retardant
Temperature range

Normal operating temperature: +90°C

Minimum operating temperature: 0°C

Flexibility Semi-rigid
Resistance to

Chemical exposure: Occasional

Mechanical impact: Light

Water exposure:Occasional condensation

Solar radiation and

weather exposure:Occasional

Cable design

Conductor:

Plain annealed copper conductor to AS/NZS 1125Can also be operated at temperatures up to 90°Cwhen not exposed to mechanical deformation(see AS/NZS 3008.1).

Insulation: V-90 PVC
Colours: Red, Black

Sheath: 3V-90PVC

Colour: White

Installation conditions

In free air

In conduit

In ground with protection

In duct

External building with protection

Insulation Colours

Conductor

Cable

Min.

installed

bending

radius(a)

mm

Nominal

C.S.A

mm²

Nominal

diameter

of wires
No/mm

Nominal

diameter

mm

Nominal

insulation

thickness

mm

Overall diameter mm

Approx.

mass

kg/100m

Minimum

Maximum

Major axis Major axis Major axis Major axis
TWIN FLAT PVC
Red,Black 1.0 7/0.42 1.26 0.6 6.4 4.2 6.6 4.3 5.2 15
Red,Black 1.5 7/0.50 1.56 0.6 7.1 4.5 7.3 4.6 6.4 20
Red,Black 2.5 7/0.67 2.0 0.7 8.7 5.4 8.9 5.5 10 20
Red,Black 4 7/0.85 2.6 0.8 10.4 6.3 10.7 6.5 15 25
Red,Black 6 7/1.04 3.1 0.8 11.5 6.9 11.9 7.1 20 30
Red,Black 10 7/1.35 4.1 1 14.2 8.4 15.0 8.8 31 35
Red,Black 16 7/1.70 5.1 1 16.7 9.7 17.3 10.0 45 40
TWIN ACTIVE FLAT PVC
Red, White 1.0 7/0.42 1.26 0.6 6.4 4.2 11.7 4.3 5.2 15
Red, White 1.5 7/0.50 1.56 0.6 7.1 4.5 12.8 4.6 6.4 20
Red, White 2.5 7/0.67 2.0 0.7 8.7 5.4 15.8 5.5 10 20
Red, White 4 7/0.85 2.6 0.8 10.4 6.3 18.3 6.5 15 25
Red, White 6 7/1.04 3.1 0.8 11.5 6.9 20.1 7.1 20 30
Red, White 10 7/1.35 4.1 1.0 14.2 8.4 25.8 8.8 31 35
Red, White 16 7/1.70 5.1 1.0 16.7 9.7 17.3 10.0 45 40
CERTIFICATIONS

 

10 mm² two core TPS cable

 

 

PACKAGING

 

10mm 2 core TPS cable

Roll

10mm2 flat TPS cable 2 core

Plastic Reel

10mm PVC flat twin cable

Small Wooden Reel

APPLICATION

 

10 mm² white flat twin cable
Capsule Accommodation
10mm 2 core flat electrical cable
Prefabricated Housing
10mm2 two core flat power cable

Recreational Vehicle Wiring

 

CASE

 

10 mm² flat building cable 2 core

2020 Ford Transit AWD Camper Van Conversion

10mm AS/NZS 5000.2 twin cable

Epping Forest District Council Modular Homes

10mm2 450/750V flat twin cable

Wethersfield Modular Accommodation Deployment

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

10 mm² V-90 twin core cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

10mm 3V-90 flat cable 2 core
 
10mm2 copper twin core cable
 
10mm flat twin cable 100m
 
10 mm² twin core cable roll
 
10mm twin core cable supplier
 
10mm2 twin core cable manufacturer
 
GLOBAL CERTIFICATIONS

 

10 mm² twin core cable price

CUSTOMER PHOTOS
 

two core TPS cable for ceiling wiring

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

flat twin cable for lighting circuits
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

2 core TPS cable for fixed lighting
two core flat cable for switch wiring
twin core TPS cable for lighting control
flat twin cable for double insulated light fittings
two core TPS cable for double insulated appliances
twin core TPS cable for office wiring
two core flat cable for retail shop wiring
2 core TPS cable for hotel room wiring
flat twin cable for apartment lighting
two core building cable for classroom wiring
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

twin core flat cable for clinic office wiring
FAQ

 

Can Twin Core Cable supply double-insulated equipment?
Twin Core Cable for Double Insulated Equipment may be suitable where the equipment and installation design do not require a protective-earth connection. GERITEL WIRE can supply Two Core TPS Cable for Fixed Appliances after the customer confirms voltage, load, termination and installation method. The equipment instructions and local rules always take priority.
Can TPS Flat Twin Core Cable be used in a caravan or motorhome?
Twin Core TPS Cable for Fixed RV AC Wiring may only be considered as part of a compliant vehicle installation. Caravan wiring must meet AS/NZS 3001 and account for vibration, protection and earthing. GERITEL WIRE can provide Two Core Flat Cable for Motorhome Lighting product data, while a licensed caravan electrician approves the complete system.
Can I use Flat Twin Cable for a 12V or 24V battery circuit?
Standard TPS Flat Twin Core Cable should not be promoted as high-current battery cable. RV battery and inverter DC connections normally require flexible conductors, suitable terminals and voltage-drop calculations. GERITEL WIRE can supply Two Core TPS Cable for Fixed AC Control Circuits where approved and recommend a separate flexible battery-cable product for the DC side.
Can Flat Twin TPS Cable be buried directly underground?
Ordinary Flat Twin TPS Cable should not be marketed as direct-burial cable. Soil, moisture and mechanical loads require an approved underground cable and installation method. GERITEL WIRE supplies Two Core TPS Cable for Protected Indoor Wiring and can recommend another product family for underground feeders or exposed external routes.

 

Hot Tags: 10mm two core tps flat feeder cable, China 10mm two core tps flat feeder cable manufacturers, suppliers, factory, 3 Core TPS Cable, SAA Australia Flat 2C E Electrical TPS Cable, SAA Australia Flat Twin Active TPS Cable, tps cable

Send Inquiry