16mm Heavy Duty Flat Twin TPS Cable

16mm Heavy Duty Flat Twin TPS Cable
Details:
·Insulation: V-90 PVC
·Sheath: 3V-90 PVC
·APPROVALS: AS/NZS 5000.2
·Normal operating temperature: +90℃
·Minimum operating temperature: 0℃
Send Inquiry
Download
Description
Technical Parameters
Certification

16mm TPS twin core cable

PRODUCT REAL SHOT

 

16mm2 flat TPS cable
16 mm² white TPS cable
16mm PVC flat cable

16mm 3 core and earth cable

16 mm² AS/NZS 5000.2 Two Core Cable for Fixed Distribution
The 16mm Heavy Duty Flat Twin TPS Cable provides two parallel plain annealed copper conductors with V-90 PVC insulation and a white 3V-90 PVC sheath. Its 450/750V construction is manufactured to AS/NZS 5000.2 for protected fixed distribution routes and dedicated equipment circuits where no earth conductor is required inside the cable. Relevant applications include Two Core Flat Cable for Prefabricated Building Distribution, Twin Core TPS Cable for Large Modular Accommodation and 16 mm² Flat Building Cable for Light Commercial Feeders. GERITEL WIRE can provide specification confirmation, samples, customised marking, factory testing and export packing, while engineers confirm current capacity and voltage drop.
PRODUCT SPECIFICATIONS

 

16mm2 flat twin core cable

Applications

 

For general wiring, unenclosed, enclosed in conduit,for domestic, commercial and industrial installations where not subject to mechanical damage.

SPECIFICATIONS
Cable description PVC insulated laid flat and PVC sheathed cableto A5/NZ5 5000.2
Approvals A5/NZS5000.2
Behaviour in flame and fire Flame retardant
Temperature range

Normal operating temperature: +90°C

Minimum operating temperature: 0°C

Flexibility Semi-rigid
Resistance to

Chemical exposure: Occasional

Mechanical impact: Light

Water exposure:Occasional condensation

Solar radiation and

weather exposure:Occasional

Cable design

Conductor:

Plain annealed copper conductor to AS/NZS 1125Can also be operated at temperatures up to 90°Cwhen not exposed to mechanical deformation(see AS/NZS 3008.1).

Insulation: V-90 PVC
Colours: Red, Black

Sheath: 3V-90PVC

Colour: White

Installation conditions

In free air

In conduit

In ground with protection

In duct

External building with protection

Insulation Colours

Conductor

Cable

Min.

installed

bending

radius(a)

mm

Nominal

C.S.A

mm²

Nominal

diameter

of wires
No/mm

Nominal

diameter

mm

Nominal

insulation

thickness

mm

Overall diameter mm

Approx.

mass

kg/100m

Minimum

Maximum

Major axis Major axis Major axis Major axis
TWIN FLAT PVC
Red,Black 1.0 7/0.42 1.26 0.6 6.4 4.2 6.6 4.3 5.2 15
Red,Black 1.5 7/0.50 1.56 0.6 7.1 4.5 7.3 4.6 6.4 20
Red,Black 2.5 7/0.67 2.0 0.7 8.7 5.4 8.9 5.5 10 20
Red,Black 4 7/0.85 2.6 0.8 10.4 6.3 10.7 6.5 15 25
Red,Black 6 7/1.04 3.1 0.8 11.5 6.9 11.9 7.1 20 30
Red,Black 10 7/1.35 4.1 1 14.2 8.4 15.0 8.8 31 35
Red,Black 16 7/1.70 5.1 1 16.7 9.7 17.3 10.0 45 40
TWIN ACTIVE FLAT PVC
Red, White 1.0 7/0.42 1.26 0.6 6.4 4.2 11.7 4.3 5.2 15
Red, White 1.5 7/0.50 1.56 0.6 7.1 4.5 12.8 4.6 6.4 20
Red, White 2.5 7/0.67 2.0 0.7 8.7 5.4 15.8 5.5 10 20
Red, White 4 7/0.85 2.6 0.8 10.4 6.3 18.3 6.5 15 25
Red, White 6 7/1.04 3.1 0.8 11.5 6.9 20.1 7.1 20 30
Red, White 10 7/1.35 4.1 1.0 14.2 8.4 25.8 8.8 31 35
Red, White 16 7/1.70 5.1 1.0 16.7 9.7 17.3 10.0 45 40
CERTIFICATIONS

 

16 mm² two core TPS cable

 

 

PACKAGING

 

16mm 2 core TPS cable

Roll

16mm2 flat TPS cable 2 core

Plastic Reel

16mm PVC flat twin cable

Small Wooden Reel

APPLICATION

 

16 mm² white flat twin cable
Capsule Accommodation
16mm 2 core flat electrical cable
Prefabricated Housing
16mm2 two core flat power cable

Recreational Vehicle Wiring

 

CASE

 

16 mm² flat building cable 2 core

2020 Ford Transit AWD Camper Van Conversion

16mm AS/NZS 5000.2 twin cable

Epping Forest District Council Modular Homes

16mm2 450/750V flat twin cable

Wethersfield Modular Accommodation Deployment

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

16 mm² V-90 twin core cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

16mm 3V-90 flat cable 2 core
 
16mm2 copper twin core cable
 
16mm flat twin cable 100m
 
16 mm² twin core cable roll
 
16mm twin core cable supplier
 
16mm2 twin core cable manufacturer
 
GLOBAL CERTIFICATIONS

 

16 mm² twin core cable price

CUSTOMER PHOTOS
 

two core TPS cable for ceiling wiring

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

flat twin cable for lighting circuits
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

2 core flat power cable for light commercial buildings
two core TPS cable for commercial lighting
twin core TPS cable for prefabricated house
two core flat cable for prefab home wiring
2 core TPS cable for prefabricated building wiring
flat twin cable for factory built homes
twin core cable for integrated house wiring
two core TPS cable for integrated homes
2 core flat cable for modular home wiring
flat twin cable for modular building electrical wiring
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

twin core TPS cable for modular accommodation
FAQ

 

Does Twin Core Cable need to be installed in conduit?
Whether Flat Twin Cable in Conduit is required depends on the route and risk of mechanical damage. Conduit, grommets or protected cavities may be needed through metal framing, exposed areas or vulnerable penetrations. GERITEL WIRE supplies Protected Fixed Wiring Two Core TPS Cable; the installer selects the approved support and protection method.
Can Flat Twin Cable be installed in roof or ceiling spaces?
Flat Twin TPS Cable for Ceiling Wiring can be installed in suitable protected fixed routes, but roof temperature, thermal insulation and cable grouping can reduce allowable current. GERITEL WIRE provides technical information for Two Core Cable for Roof Space Lighting; the designer applies the correct derating and the installer protects the cable from future damage.
What roll or drum lengths can GERITEL WIRE supply?
100m Roll Flat Twin Cable is a common market request, while larger sizes or project quantities may use longer drums. GERITEL WIRE can review standard and customised lengths for TPS Flat Twin Core Cable Packaging, considering cable size, total metres, unloading method and container efficiency before confirming the packing plan.
Can GERITEL WIRE print my brand or metre marks on the cable?
OEM marking can be discussed for Custom Printed TPS Flat Twin Core Cable when the order quantity and approved artwork meet production requirements. GERITEL WIRE can add brand, size, voltage and suitable identification, and can review metre marking for Private Label Two Core Flat Cable. Printing must not imply an unapproved certification.

 

Hot Tags: 16mm heavy duty flat twin tps cable, China 16mm heavy duty flat twin tps cable manufacturers, suppliers, factory, 3 Core TPS Cable, SAA Australia Flat 2C E Electrical TPS Cable, SAA Australia Flat Twin Active TPS Cable, tps cable

Send Inquiry