Twin And Earth Cable – Copper PVC Building Cable

Twin And Earth Cable – Copper PVC Building Cable
Details:
·Insulation: V-90 PVC
·Sheath: 3V-90 PVC
·APPROVALS: AS/NZS 5000.2
·Normal operating temperature: +90℃
·Minimum operating temperature: 0℃
Send Inquiry
Download
Description
Technical Parameters
Certification

PVC sheathed flat building cable

PRODUCT REAL SHOT

 

flat building cable for building wiring
low voltage flat building cable
electrical wiring flat building cable

house wiring flat building cable

Flat Twin And Earth Cable with V-90 PVC Insulation for Fixed Installation
This twin and earth cable page targets fixed power and lighting work where installers value a flat profile and consistent cable construction. It uses copper conductors with V-90 PVC insulation and a PVC sheath; relevant 450/750V constructions can be supplied to AS/NZS 5000.2. For Power & lighting, it can serve suitable fixed power and lighting routes after cable size and installation conditions are confirmed. Related search terms include flat twin and earth cable and power and lighting cable. GERITEL WIRE supplies prefab-home factories, RV builders and capsule-house projects with direct-factory service and export support. Final size, core configuration and installation method should follow the project drawings and local electrical rules.
PRODUCT SPECIFICATIONS

 

Australia flat electrical cable

Applications

 

For general wiring, unenclosed, enclosed in conduit,for domestic, commercial and industrial installations where not subject to mechanical damage.

SPECIFICATIONS
Cable description PVC insulated laid flat and PVC sheathed cableto A5/NZ5 5000.2
Approvals A5/NZS5000.2
Behaviour in flame and fire Flame retardant
Temperature range

Normal operating temperature: +90°C

Minimum operating temperature: 0°C

Flexibility Semi-rigid
Resistance to

Chemical exposure: Occasional

Mechanical impact: Light

Water exposure:Occasional condensation

Solar radiation and

weather exposure:Occasional

Cable design

Conductor:

Plain annealed copper conductor to AS/NZS 1125Can also be operated at temperatures up to 90°Cwhen not exposed to mechanical deformation(see AS/NZS 3008.1).

Insulation: V-90 PVC
Colours: Red, Black

Sheath: 3V-90PVC

Colour: White

Installation conditions

In free air

In conduit

In ground with protection

In duct

External building with protection

Insulation Colours

Conductor

Cable

Min.

installed

bending

radius(a)

mm

Nominal

C.S.A

mm²

Nominal

diameter

of wires
No/mm

Nominal

diameter

mm

Nominal

insulation

thickness

mm

Overall diameter mm

Approx.

mass

kg/100m

Minimum

Maximum

Major axis Major axis Major axis Major axis
TWIN FLAT PVC
Red,Black 1.0 7/0.42 1.26 0.6 6.4 4.2 6.6 4.3 5.2 15
Red,Black 1.5 7/0.50 1.56 0.6 7.1 4.5 7.3 4.6 6.4 20
Red,Black 2.5 7/0.67 2.0 0.7 8.7 5.4 8.9 5.5 10 20
Red,Black 4 7/0.85 2.6 0.8 10.4 6.3 10.7 6.5 15 25
Red,Black 6 7/1.04 3.1 0.8 11.5 6.9 11.9 7.1 20 30
Red,Black 10 7/1.35 4.1 1 14.2 8.4 15.0 8.8 31 35
Red,Black 16 7/1.70 5.1 1 16.7 9.7 17.3 10.0 45 40
TWIN ACTIVE FLAT PVC
Red, White 1.0 7/0.42 1.26 0.6 6.4 4.2 11.7 4.3 5.2 15
Red, White 1.5 7/0.50 1.56 0.6 7.1 4.5 12.8 4.6 6.4 20
Red, White 2.5 7/0.67 2.0 0.7 8.7 5.4 15.8 5.5 10 20
Red, White 4 7/0.85 2.6 0.8 10.4 6.3 18.3 6.5 15 25
Red, White 6 7/1.04 3.1 0.8 11.5 6.9 20.1 7.1 20 30
Red, White 10 7/1.35 4.1 1.0 14.2 8.4 25.8 8.8 31 35
Red, White 16 7/1.70 5.1 1.0 16.7 9.7 17.3 10.0 45 40
CERTIFICATIONS

 

Australian standard flat electrical cable

 

 

PACKAGING

 

New Zealand flat electrical cable

Roll

SAA approved flat electrical cable

Plastic Reel

SAA certified flat electrical cable

Small Wooden Reel

APPLICATION

 

flat electrical cable for fixed wiring
Capsule Accommodation
flat electrical cable for power circuits
Prefabricated Housing
flat electrical cable for lighting circuits

Recreational Vehicle Wiring

 

CASE

 

flat electrical cable for residential wiring

2020 Ford Transit AWD Camper Van Conversion

flat electrical cable for commercial wiring

Epping Forest District Council Modular Homes

copper conductor flat electrical cable

Wethersfield Modular Accommodation Deployment

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

PVC insulated flat electrical cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

PVC sheathed flat electrical cable
 
flat electrical cable for building wiring
 
low voltage flat electrical cable
 
electrical wiring flat electrical cable
 
house wiring flat electrical cable
 
Australia TPS building wire
 
GLOBAL CERTIFICATIONS

 

6 mm² twin core cable price

CUSTOMER PHOTOS
 

Australian standard TPS building wire

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

New Zealand TPS building wire
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

SAA approved TPS building wire
SAA certified TPS building wire
3V-90 flat twin cable
TPS building wire for residential wiring
TPS building wire for commercial wiring
flat twin cable without earth
TPS building wire for fixed wiring
TPS building wire for power circuits
TPS building wire for lighting circuits
copper conductor TPS building wire
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

PVC insulated TPS building wire
FAQ

 

What conductor material does GERITEL WIRE use in Flat TPS Cable?
The product uses copper conductors for dependable electrical conductivity. For orders, GERITEL WIRE can confirm conductor construction, nominal cross-section and applicable conductor requirements before production. In international sourcing, useful equivalent search terms include copper conductor TPS cable and plain annealed copper TPS cable, but final approval should be based on the technical specification. If the project has special installation or certification requirements, GERITEL WIRE can review them before quotation to reduce later changes. The electrician or project engineer should confirm final cable selection for the actual installation.
What is V-90 insulation in Flat TPS Cable?
V-90 refers to a PVC insulation grade used in Australian building cables. It is designed for elevated operating temperature within the conditions permitted by the relevant wiring rules and cable standard. Related catalog descriptions include V-90 insulated flat TPS cable and V90 TPS cable; the correct choice still depends on the ordered model and application. For project orders, GERITEL WIRE can align cable size, core arrangement, packaging and documentation with the approved BOM. Clear technical confirmation before purchase helps reduce rework, approval delays and site substitutions.
What is the purpose of the PVC outer sheath on Flat TPS Cable?
The outer sheath holds the insulated cores in a flat profile and provides everyday mechanical and installation protection for protected fixed-wiring routes. For procurement, this requirement may be listed as PVC sheathed flat cable or PVC insulated flat cable, so the datasheet and core configuration should be checked with the supplier. For distributors and OEM builders, GERITEL WIRE can support stable production batches, custom identification and export-ready packaging. For regulated projects, certificate scope and installation requirements should be checked together.
Why does Flat TPS Cable use separate insulation colours on the cores?
Core colours help electricians identify circuit conductors during installation and maintenance. Actual colour assignment must follow the applicable local wiring rules and ordered construction. When comparing supplier listings, buyers may also see the terms flat cable red black green yellow cores and TPS building wire; always compare the actual construction, not the label alone. GERITEL WIRE can confirm the ordered construction, marking and available compliance files before production. Final installation should follow the project drawings and applicable local electrical rules.

 

Hot Tags: twin and earth cable – copper pvc building cable, China twin and earth cable – copper pvc building cable manufacturers, suppliers, factory, 3 Core TPS Cable, SAA Australia Flat 2C E Electrical TPS Cable, SAA Australia Flat Twin Active TPS Cable, tps cable

Send Inquiry