·Conductor: Aluminum
·Insulation: Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
·Armour: Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
·Voltage Rating: 600V
·Application: Data Center Infrastructure、Large-Scale Equipment Manufacturing、Mining Equipment Manufacturing、Hydropower Plants、Oil Refining Industry、Building Materials Industry、Non-Ferrous Metal Industry
Send Inquiry
Download
Description
Technical Parameters
Certification

Dongguan Greater Wire & Cable Co., Ltd. is one of the leading manufacturers and suppliers of csa ac90 aluminum cable 3 conductor for panel homeruns and distribution wiring in China, also supports customized service. Please rest assured to wholesale durable csa ac90 aluminum cable 3 conductor for panel homeruns and distribution wiring made in China here from our factory. If you have any enquiry about free sample, please feel free to email us.

 

AC90 3 conductor aluminum cable for utility room wiring

PRODUCT REAL SHOT

 

AC90 3 conductor aluminum cable for utility room wiring
AC90 3 conductor aluminum cable for panelboard wiring
AC90 3 conductor aluminum cable for panel homerun wiring

AC90 3 conductor aluminum cable for distribution panel wiring

600V armoured building cable for electrical rooms panelboards and feeder runs
CSA AC90 aluminum cable is designed for panel homeruns, distribution boards, electrical rooms and suitable feeder circuits. The cable uses three insulated 8000 Series ACM aluminum conductors with RW90 XLPE insulation, a bare aluminum bonding conductor, paper binder and flexible interlocked aluminum armour in a 600V building-wire construction. This combination reduces conductor weight while providing practical mechanical protection and routing flexibility for permanent building wiring. GERITEL WIRE supplies AC90 aluminum power distribution cable with project quantity support, cable marking, reel packaging and technical documentation. The product is intended for suitable dry-location installations, and final ampacity, conductor functions, overcurrent protection, connector selection and installation method should follow the exact product data, project design and applicable Canadian electrical code.
PRODUCT SPECIFICATIONS

 

AC90 3 conductor aluminum cable for power distribution wiring

AC90 Cable Overview

 

GERITEL WIRE AC90 cable with its interlocked aluminum armour is designed for aboveground applications. The distinctive features unique to GERITEL WIRE AC90 cable provide significant savings in installation cost and time. Engineered to replace conduit and wire applications, this all-in-one cable assembly offers fewer installation steps. GERITEL WIRE AC90 cable's interlocked aluminum armour protects the conductors from damage before, during and after installation and provides overall flexibility not available with a conduit.

 

GERITEL WIRE AC90 is a factory-produced 600-volt assembly of one to four insulated, phase-identified GERITEL WIRE conductors and one bare bonding conductor inside flexible interlocked aluminum armour. Cross-linked Polyethylene (XLPE) insulated conductors are rated for 90˚C.

 

Multi-conductor AC90 cables are available in sizes 6 AWG to 1500 kcmil. Single-conductor AC90 cables are available in sizes from 1 AWG to 750 kcmil but are not approved for use in hazardous locations. On single-conductor cables, the bonding conductor is applied concentrically around the phase conductor.

 

GERITEL WIRE AC90 cables meet or exceed the requirements of CSA C22.2 No. 38 and C22.2 No. 51 and are approved for use in accordance with the recommendations of the Canadian Electrical Code.

Product Features

 
  • Maximum Conductivity – Compact aluminum alloy conductors carry twice the current per kilogram as equivalent copper conductors
  • Reliable Termination – Conductors terminate safely with industry-standard dual-rated aluminum lugs
  • Exceptional Insulation – The Cross-linked Polyethylene (XLPE) insulation is rated for operating temperatures of -40˚C to +90˚C and offers a higher maximum short-circuit temperature rating than thermoplastic insulation. It is sunlightand moisture-resistant
  • Easy to Install – Lightweight for easier lifting and handling with 25% more flexibility and 40% less springback than copper conductors of equal ampacity
  • Heavy Metals Free insulation is RoHS compliant and environmentally sustainable while providing excellent long-term performance
  • Sequential meter marking

Applications

 

GERITEL WIRE AC90 armoured cable is designed for use in the following open and concealed wiring applications:

  • Service entrance and feeders
  • Power lighting and signal circuits
  • Indoors
  • Where exposed or concealed
  • In cable tray
  • In certain hazardous locations
  • In dry locations and embedded in plaster finish on brick or other masonry except in damp or wet conditions
  • Interior temporary power
SPECIFICATIONS
Conductor Aluminum
Insulation Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
Armour Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
Specifications and Compliance

CSA C22.2 No. 51, Armoured Cables (Type AC90)

CSA C22.2 No. 38 Thermoset-insulated wires and cables (Type RW90)

CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test

IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated

-40°C Cold Bend and -40°C Cold Impact

Limited Smoke and Halogen Free

AC90 Cable
600 V, CSA Type, -40⁰C to +90⁰C

SIZE
(AWG/kcmil)
BOND SIZE
(AWG/kcmil)
UNDER
ARMOUR
(mm)
OVER
ARMOUR
(mm)
CONDUCTOR
WEIGHT
(kg/km)

CABLE
WEIGHT
(kg/km)

Min Bend Radius
AMPACITY(1)
75°C
AMPACITY(1)
90°C
SINGLE CONDUCTOR
1 4 13.0 18.8 117 324 100 115
1/0 4 14.0 19.8 148 397 120 135
2/0 2 14.9 20.7 186 446 135 150
3/0 2 16.1 22.0 235 508 155 175
4/0 2 17.7 23.6 296 610 180 205
250 1 19.4 25.2 350 688 205 230
300 1 20.7 26.5 420 774 230 260
350 1/0 22.1 27.9 490 889 250 280
400 1/0 23.5 29.3 560 960 270 305
500 2/0 25.8 31.7 700 1161 310 350
600 2/0 28.3 34.1 840 1370 340 385
750 3/0 30.7 36.5 1050 1604 385 435
THREE CONDUCTOR
6 8 14.4 19.4 133 311 50 55
4 6 17.3 22.2 212 422 65 75
2 6 19.6 24.5 316 559 90 100
1 4 22.4 27.3 410 708 100 115
1/0 4 24.0 29.0 502 829 120 135
2/0 4 26.0 30.8 618 977 135 150
3/0 4 28.5 33.4 764 1164 155 175
4/0 4 31.2 36.1 948 1394 180 205
250 2 34.7 41.3 1143 1726 205 230
300 2 37.5 44.2 1354 1991 230 260
350 2 39.8 46.4 1564 2247 250 280
400 2 42.6 49.4 1774 2491 270 305
500 1 46.8 53.6 2218 3013 310 350
600 1 51.1 57.8 2638 3507 340 385
750 1/0 56.3 63.0 3299 4267 385 435
1000 1/0 64.6 71.3 4350 5478 445 500
1500† 2/0 83.9 90.6 6489 8102 520 585
FOUR CONDUCTOR
6 8 16.6 21.5 170 382 50 55
4 6 19.7 24.6 271 521 65 75
2 6 22.5 27.4 409 701 90 100
1 4 25.6 30.6 527 904 100 115
1/0 4 27.6 32.5 650 1050 120 135
2/0 4 29.5 34.4 804 1242 135 150
3/0 4 32.0 36.9 999 1485 155 175
4/0 4 35.0 41.6 1244 1840 180 205
250 2 39.0 45.8 1949 2222 205 230
300 2 42.1 48.8 1774 2570 230 260
350 2 44.6 51.3 2054 2907 250 280
400 2 47.8 54.5 2334 3198 270 305
500 1 52.5 59.2 2919 3878 310 350
600 1 57.2 63.9 3479 4530 340 385
750 1/0 63.0 69.8 4350 5525 385 435
1000 1/0 72.3 79.1 5750 7125 445 500
1500† 2/0 94.0 100.7 8590 10580 520 585

(1) Ampacity based on the 2015 Canadian Electrical Code Part 1 Table 4, Rule 4-004 and Rule 4-006 apply.

† ASTM B231 and ASTM B801 Class B conventional stranding.
All dimensions are nominal and subject to industry standard and manufacturing tolerances.

CERTIFICATIONS

 

AC90 3 conductor aluminum cable for lighting panel wiring

PACKAGING

 

AC90 3 conductor aluminum cable for electrical panel supply wiring

Roll

AC90 3 conductor aluminum cable for electrical cabinet supply wiring

Small Wooden Reel

AC90 3 conductor aluminum cable for power cabinet feeder wiring

Large Wooden Reel

APPLICATION

 

AC90 3 conductor aluminum cable for power cabinet feeder wiring
Apartment/Residential Building Electrical Distribution
AC90 3 conductor aluminum cable for distribution cabinet supply wiring
Commercial Building Electrical Distribution
AC90 3 conductor aluminum cable for switchgear room building wiring
Energy Storage Systems Industry
CASE

 

AC90 3 conductor aluminum cable for three phase three conductor wiring

Calgary Alberta Multi Storey Apartment Construction Upgrade

AC90 3 conductor aluminum cable for commercial lighting circuits

Toronto Ontario Detached House Basement Panel Upgrade

AC90 3 conductor aluminum cable for ceiling fixture wiring

Vancouver British Columbia Downtown Office Renovation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

AC90 3 conductor aluminum cable for receptacle circuit wiring
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

AC90 3 conductor aluminum cable for general purpose power circuits
 
AC90 3 conductor aluminum cable for building service space wiring
 
AC90 3 conductor aluminum cable for above ceiling wiring
 
AC90 3 conductor aluminum cable for ceiling space wiring
 
AC90 3 conductor aluminum cable for wall cavity wiring
 
AC90 3 conductor aluminum cable for steel stud wall wiring
 
GLOBAL CERTIFICATIONS

 

AC90 3 conductor aluminum cable for metal stud wall wiring

CUSTOMER PHOTOS
 

AC90 3 conductor aluminum cable for drywall partition wiring

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

AC90 3 conductor aluminum cable for open wiring in dry locations
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

AC90 3 conductor aluminum cable for concealed wiring in dry locations
AC90 3 conductor aluminum cable for cable trough wiring
AC90 3 conductor aluminum cable for ventilated cableway wiring
AC90 3 conductor aluminum cable for dry location cable tray wiring
AC90 3 conductor aluminum cable for building cableway wiring
AC90 3 conductor aluminum cable for commercial renovation wiring
AC90 3 conductor aluminum cable for building retrofit wiring
AC90 3 conductor aluminum cable for electrical rough in wiring
AC90 3 conductor aluminum cable for commercial rough in wiring
AC90 3 conductor aluminum cable for interior retrofit wiring
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

AC90 3 conductor aluminum cable for modular building wiring
FAQ

 

Does AC90 aluminum cable need to be supported?
Yes. AC90 aluminum cable installation must be properly secured and supported according to the applicable electrical code and installation instructions.
Can AC90 aluminum cable be bent sharply?
No. flexible AC90 aluminum cable should not be kinked or bent tighter than the permitted minimum bend radius because excessive bending can damage the armour or conductor assembly.
What Canadian standard applies to AC90 aluminum cable?
CSA AC90 aluminum cable is evaluated under applicable Canadian requirements for armoured cable. Buyers should verify the exact standard references and certificate for the ordered model.
Does AC90 aluminum meet CSA C22.2 No. 51?
A properly certified CSA C22.2 No. 51 AC90 cable can be evaluated to CSA C22.2 No. 51 for armoured cables. Always confirm the exact model and certification documentation.
 

 

Hot Tags: csa ac90 aluminum cable 3 conductor for panel homeruns and distribution wiring, China csa ac90 aluminum cable 3 conductor for panel homeruns and distribution wiring manufacturers, suppliers, factory

Send Inquiry