AC90 Copper Cable 2C Black Red 600V For Mechanical Room Wiring

AC90 Copper Cable 2C Black Red 600V For Mechanical Room Wiring
Details:
·Conductor: Solid Soft Copper, ASTM B3
·Insulation: Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
·Colour Code: Black, Red
·Bonding Conductor: Solid ASTM B3 Soft Bare Copper
·Armour: Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
·Voltage Rating: 600V
Send Inquiry
Download
Description
Technical Parameters
Certification

Dongguan Greater Wire & Cable Co., Ltd. is one of the leading manufacturers and suppliers of ac90 copper cable 2c black red 600v for mechanical room wiring in China, also supports customized service. Please rest assured to wholesale durable ac90 copper cable 2c black red 600v for mechanical room wiring made in China here from our factory. If you have any enquiry about free sample, please feel free to email us.

 

AC90 cable for panelboard feeder wiring

PRODUCT REAL SHOT

 

AC90 wire for panelboard feeder wiring
AC90 cable for electrical enclosure supply cable
AC90 wire for electrical enclosure supply cable

AC90 cable for control cabinet power supply wiring

Flexible armoured power wiring for dry indoor equipment spaces
Designed around the needs of mechanical room wiring, AC90 cable for mechanical rooms combines electrical performance and mechanical protection in a compact armoured construction. The cable uses copper conductors, RW90 XLPE insulation, paper wrap, a bonding conductor and interlocked aluminum armour, with Black/Red identification for the two circuit conductors. This 600V design supports suitable dry indoor branch-circuit applications and helps installers route cable efficiently through framed interiors and service areas. GERITEL WIRE manufactures AC90 copper cable for B2B customers requiring stable quality, custom markings, packaging options and coordinated project supply. Final application should always follow the current product marking, project specification and applicable electrical code.
PRODUCT SPECIFICATIONS

 

AC90 wire for control cabinet power supply wiring

APPLICATIONS

 

Manufactured, tested and certified in Canada, GERITEL WIRE AC90 armoured building wire is rated FT4-ST1 for -40°C to 90°C. Engineered specifically for demanding environments, superior flammability and smoke emission performance.

Designed for Single-Phase Heating Installations.

For use in ventilated, non-ventilated and ladder-type cable trays.

For dry locations, in ceiling air-handling plenums, exposed or concealed wiring and service entrance above ground.

SPECIFICATIONS
Conductor Solid Soft Copper, ASTM B3
Insulation Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
Colour Code Black, Red
Bonding Conductor Solid ASTM B3 Soft Bare Copper
Armour Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
Specifications and Compliance

CSA C22.2 No. 51, Armoured Cables (Type AC90)

CSA C22.2 No. 38 Thermoset-insulated wires and cables (Type RW90)

CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test

IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated

-40°C Cold Bend and -40°C Cold Impact

Limited Smoke and Halogen Free

AC90 & ISO-AC90 600V CSA FT4-ST1 LSZH

 

AC90

Power

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
Count AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 0.030 0.76 0.430 10.9 81 120 66 30 6.0 151 25
2 12 14 0.030 0.76 0.454 11.5 99 148 104 47 6.4 164 30
2 10 12 0.030 0.76 0.512 13.0 138 206 166 75 6.9 174 40
3 14 14 0.030 0.76 0.445 11.3 105 156 99 45 6.2 158 25
3 12 14 0.030 0.76 0.490 12.4 130 193 157 71 6.9 174 30
3 10 12 0.030 0.76 0.535 13.6 182 271 249 113 7.5 190 40
3 8/7 10 0.045 1.14 0.714 18.1 309 460 418 190 10.0 254 55
3 6/7 8/7 0.045 1.14 0.770 19.6 417 621 702 318 10.8 274 75
3 4/7 8/7 0.045 1.14 0.940 23.9 601 894 1193 541 13.2 334 95
3 3/7 6/7 0.045 1.14 0.990 25.1 721 1073 1622 736 13.9 352 115
3 2/7 6/7 0.045 1.14 1.040 26.4 891 1326 1922 872 14.6 370 130
4 14 14 0.030 0.76 0.490 12.4 130 193 131 60 6.9 174 20
4 12 14 0.030 0.76 0.535 13.6 166 247 209 95 7.5 190 24
4 10 12 0.030 0.76 0.630 16.0 232 345 332 150 8.8 224 32

 

ISO-AC90

Conductor

Count

Power

Conductor

Ins.Ground

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
AWG AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 14 0.030 0.76 0.440 11.2 105 156 66 30 6.2 157 25
2 12 12 14 0.030 0.76 0.485 12.3 138 206 104 47 6.8 173 30
2 10 10 12 0.030 0.76 0.533 13.5 186 277 166 75 7.5 190 40
3 12 12 14 0.030 0.76 0.535 13.6 165 245 157 71 7.5 190 24
3 10 10 12 0.030 0.76 0.591 15.0 232 346 249 113 8.3 210 32
CERTIFICATIONS

 

AC90 cable for solar facility indoor auxiliary wiring

PACKAGING

 

AC90 wire for solar facility indoor auxiliary wiring

Roll

AC90 cable for solar project control room building wiring

Plastic Reel

AC90 wire for solar project control room building wiring

Small Wooden Reel

APPLICATION

 

AC90 cable for renewable energy facility indoor wiring
Apartment/Residential Building Electrical Distribution
AC90 wire for renewable energy facility indoor wiring
Commercial Building Electrical Distribution
AC90 cable for battery energy storage facility auxiliary wiring
Industrial Factory Power Distribution
CASE

 

AC90 wire for battery energy storage facility auxiliary wiring

Calgary Alberta Multi Storey Apartment Construction Upgrade

AC90 cable for BESS control room building wiring

Toronto Ontario Detached House Basement Panel Upgrade

AC90 wire for BESS control room building wiring

Vancouver British Columbia Downtown Office Renovation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

AC90 cable for BESS lighting circuit wiring
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

AC90 wire for BESS lighting circuit wiring
 
AC90 cable for BESS receptacle circuit wiring
 
AC90 wire for BESS receptacle circuit wiring
 
AC90 cable for energy storage facility indoor power wiring
 
AC90 wire for energy storage facility indoor power wiring
 
AC90 cable for EV charging facility indoor branch wiring
 
GLOBAL CERTIFICATIONS

 

AC90 wire for EV charging facility indoor branch wiring

CUSTOMER PHOTOS
 

AC90 cable for EV charger electrical room wiring

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

AC90 wire for EV charger electrical room wiring
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

AC90 cable for green building electrical wiring
AC90 wire for green building electrical wiring
AC90 cable for low carbon building wiring
AC90 wire for low carbon building wiring
AC90 cable for LEED project building wiring
AC90 wire for LEED project building wiring
AC90 cable for low smoke building wiring
AC90 wire for low smoke building wiring
AC90 cable for zero halogen building wiring
AC90 wire for zero halogen building wiring
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

AC90 cable for FT4 commercial building wiring
FAQ

 

Can AC90 be used in a data center UPS room?
AC90 cable for UPS room wiring can be used for general dry-location building and auxiliary circuits. It should not be used as a UPS battery interconnect cable unless specifically designed for that function.
Can AC90 be used in telecom rooms?
Yes. AC90 cable for telecom room wiring can supply general building-power circuits in dry communications spaces. Isolated-ground equipment circuits should be reviewed separately.
Can AC90 be used in prefabricated wiring systems?
AC90 prefabricated wiring cable can be incorporated into listed manufactured wiring systems where the system design, certification and local code permit AC90.
Can AC90 be used for container-house interior wiring?
AC90 cable for container house wiring can be used for suitable dry indoor circuits if the construction system and local electrical code permit it. Protection at metal penetrations and correct bonding are especially important..
 

 

Hot Tags: ac90 copper cable 2c black red 600v for mechanical room wiring, China ac90 copper cable 2c black red 600v for mechanical room wiring manufacturers, suppliers, factory

Send Inquiry