600V 12/2 AC90 Armoured Cable Copper 2 Conductor For Building Wiring

600V 12/2 AC90 Armoured Cable Copper 2 Conductor For Building Wiring
Details:
·Conductor: Solid Soft Copper, ASTM B3
·Insulation: Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
·Colour Code: Black, White
·Bonding Conductor: Solid ASTM B3 Soft Bare Copper
·Armour: Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
·Voltage Rating: 600V
Send Inquiry
Download
Description
Technical Parameters
Certification

AC90 cable

PRODUCT REAL SHOT

 

AC90 wire
AC90 armoured cable
AC90 armored cable

AC90 building wire

Reliable indoor branch circuit wiring for Canadian projects
Designed for dependable indoor power distribution, AC90 armoured cable combines copper conductors, RW90 XLPE insulation, a bonding conductor and interlocked aluminum armour in one practical building-wiring solution. The 2 conductor black/white configuration is well suited to branch circuits, lighting and receptacle runs in commercial, residential and multi-residential projects. For contractors and distributors seeking a durable copper AC90 cable, GERITEL WIRE supports project quantities, OEM marking, packaging options and stable production scheduling. The 600V construction is intended for dry-location installations where mechanical protection, flexible routing and efficient installation are important.
PRODUCT SPECIFICATIONS

 

AC90 building cable

APPLICATIONS

 

Manufactured, tested and certified in Canada, GERITEL WIRE AC90 armoured building wire is rated FT4-ST1 for -40°C to 90°C. Engineered specifically for demanding environments, superior flammability and smoke emission performance.

For use in ventilated, non-ventilated and ladder-type cable trays.

For dry locations, in ceiling air-handling plenums, exposed or concealed wiring and service entrance above ground.

SPECIFICATIONS
Conductor Solid Soft Copper, ASTM B3
Insulation Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
Colour Code Black, White
Bonding Conductor Solid ASTM B3 Soft Bare Copper
Armour Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
Specifications and Compliance

CSA C22.2 No. 51, Armoured Cables (Type AC90)

CSA C22.2 No. 38 Thermoset-insulated wires and cables (Type RW90)

CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test

IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated

-40°C Cold Bend and -40°C Cold Impact

Limited Smoke and Halogen Free

AC90 & ISO-AC90 600V CSA FT4-ST1 LSZH

 

AC90

Power

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
Count AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 0.030 0.76 0.430 10.9 81 120 66 30 6.0 151 25
2 12 14 0.030 0.76 0.454 11.5 99 148 104 47 6.4 164 30
2 10 12 0.030 0.76 0.512 13.0 138 206 166 75 6.9 174 40
3 14 14 0.030 0.76 0.445 11.3 105 156 99 45 6.2 158 25
3 12 14 0.030 0.76 0.490 12.4 130 193 157 71 6.9 174 30
3 10 12 0.030 0.76 0.535 13.6 182 271 249 113 7.5 190 40
3 8/7 10 0.045 1.14 0.714 18.1 309 460 418 190 10.0 254 55
3 6/7 8/7 0.045 1.14 0.770 19.6 417 621 702 318 10.8 274 75
3 4/7 8/7 0.045 1.14 0.940 23.9 601 894 1193 541 13.2 334 95
3 3/7 6/7 0.045 1.14 0.990 25.1 721 1073 1622 736 13.9 352 115
3 2/7 6/7 0.045 1.14 1.040 26.4 891 1326 1922 872 14.6 370 130
4 14 14 0.030 0.76 0.490 12.4 130 193 131 60 6.9 174 20
4 12 14 0.030 0.76 0.535 13.6 166 247 209 95 7.5 190 24
4 10 12 0.030 0.76 0.630 16.0 232 345 332 150 8.8 224 32

 

ISO-AC90

Conductor

Count

Power

Conductor

Ins.Ground

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
AWG AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 14 0.030 0.76 0.440 11.2 105 156 66 30 6.2 157 25
2 12 12 14 0.030 0.76 0.485 12.3 138 206 104 47 6.8 173 30
2 10 10 12 0.030 0.76 0.533 13.5 186 277 166 75 7.5 190 40
3 12 12 14 0.030 0.76 0.535 13.6 165 245 157 71 7.5 190 24
3 10 10 12 0.030 0.76 0.591 15.0 232 346 249 113 8.3 210 32
CERTIFICATIONS

 

AC90 copper cable

PACKAGING

 

AC90 copper wire

Roll

copper AC90 cable

Plastic Reel

copper AC90 wire

Small Wooden Reel

APPLICATION

 

AC90 copper conductor cable
Apartment/Residential Building Electrical Distribution
AC90 copper conductor wire
Commercial Building Electrical Distribution
AC90 metal clad cable
Industrial Factory Power Distribution
CASE

 

AC90 metal-clad cable

Calgary Alberta Multi Storey Apartment Construction Upgrade

AC90 metal clad wire

Toronto Ontario Detached House Basement Panel Upgrade

AC90 armoured wire

Vancouver British Columbia Downtown Office Renovation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

AC90 armored wire
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

AC90 electrical cable
 
AC90 electrical wire
 
AC90 power cable
 
AC90 power wire
 
AC90 branch circuit cable
 
AC90 branch circuit wire
 
GLOBAL CERTIFICATIONS

 

AC90 flexible armoured cable

CUSTOMER PHOTOS
 

AC90 flexible armored cable

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

AC90 interlocked armoured cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

AC90 interlocked armored cable
AC90 aluminum interlocked armour cable
AC90 aluminum interlocked armor cable
10/2 CSA AC90 cable
10/2 cUL CSA AC90 cable
AC90 copper building wire
AC90 copper building cable
AC90 2 conductor cable
AC90 two conductor cable
AC90 2 conductor wire
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

AC90 two conductor wire
FAQ

 

What is the main advantage of AC90 over unarmoured building wire?
The key advantage of AC90 armored cable is the integrated metallic armour around the insulated conductors. This adds mechanical protection while maintaining a flexible cable form, which can simplify routing in many commercial and residential interior installations.
Is AC90 only used in Canada?
Canadian AC90 cable is strongly associated with the Canadian electrical market and Canadian armoured-cable standards. Buyers in other markets should confirm local code acceptance and certification requirements before specifying AC90.
Can AC90 be supplied without an outer PVC jacket?
Standard bare armour AC90 cable typically has exposed interlocked aluminum armour rather than a continuous outer PVC jacket. If a project requires a jacketed armoured cable for wet, outdoor or harsher conditions, ACWU90 or another appropriate cable type should be evaluated instead.
Does AC90 include a grounding or bonding conductor?
A typical AC90 bonding conductor construction includes a copper bonding conductor as part of the cable assembly. This conductor supports the equipment bonding path, while the two black/white insulated conductors are the circuit conductors in the 2C configuration.

 

Hot Tags: 600v 12/2 ac90 armoured cable copper 2 conductor for building wiring, China 600v 12/2 ac90 armoured cable copper 2 conductor for building wiring manufacturers, suppliers, factory

Send Inquiry