12/2 AC90 Copper Building Wire 600V 2 Conductor CUL CSA For Receptacle Wiring

12/2 AC90 Copper Building Wire 600V 2 Conductor CUL CSA For Receptacle Wiring
Details:
·Conductor: Solid Soft Copper, ASTM B3
·Insulation: Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
·Colour Code: Black, White
·Bonding Conductor: Solid ASTM B3 Soft Bare Copper
·Armour: Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
·Voltage Rating: 600V
Send Inquiry
Download
Description
Technical Parameters
Certification

12/2 AC90 cable

PRODUCT REAL SHOT

 

12/2 AC90 wire
AC90 12/2 cable
AC90 12/2 wire

12/2 AC90 armoured cable

A versatile armoured cable for common branch circuits and project supply
For common building branch circuits, 12/2 AC90 cable offers a balanced combination of copper conductivity, RW90 XLPE insulation and flexible interlocked aluminum armour. The 2 conductor black/white layout is practical for many receptacle, lighting and general-purpose circuits in apartments, offices, retail spaces, modular buildings and other dry indoor locations where AC90 is approved. GERITEL WIRE manufactures 12/2 AC90 copper wire for contractors, electrical wholesalers and project procurement teams, with support for custom printing, reel or coil packaging, production documentation and scheduled supply. The 600V armoured construction provides built-in mechanical protection and efficient routing for new construction, renovation and repeat commercial installations.
PRODUCT SPECIFICATIONS

 

12/2 AC90 armored cable

APPLICATIONS

 

Manufactured, tested and certified in Canada, GERITEL WIRE AC90 armoured building wire is rated FT4-ST1 for -40°C to 90°C. Engineered specifically for demanding environments, superior flammability and smoke emission performance.

For use in ventilated, non-ventilated and ladder-type cable trays.

For dry locations, in ceiling air-handling plenums, exposed or concealed wiring and service entrance above ground.

SPECIFICATIONS
Conductor Solid Soft Copper, ASTM B3
Insulation Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
Colour Code Black, White
Bonding Conductor Solid ASTM B3 Soft Bare Copper
Armour Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
Specifications and Compliance

CSA C22.2 No. 51, Armoured Cables (Type AC90)

CSA C22.2 No. 38 Thermoset-insulated wires and cables (Type RW90)

CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test

IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated

-40°C Cold Bend and -40°C Cold Impact

Limited Smoke and Halogen Free

AC90 & ISO-AC90 600V CSA FT4-ST1 LSZH

 

AC90

Power

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
Count AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 0.030 0.76 0.430 10.9 81 120 66 30 6.0 151 25
2 12 14 0.030 0.76 0.454 11.5 99 148 104 47 6.4 164 30
2 10 12 0.030 0.76 0.512 13.0 138 206 166 75 6.9 174 40
3 14 14 0.030 0.76 0.445 11.3 105 156 99 45 6.2 158 25
3 12 14 0.030 0.76 0.490 12.4 130 193 157 71 6.9 174 30
3 10 12 0.030 0.76 0.535 13.6 182 271 249 113 7.5 190 40
3 8/7 10 0.045 1.14 0.714 18.1 309 460 418 190 10.0 254 55
3 6/7 8/7 0.045 1.14 0.770 19.6 417 621 702 318 10.8 274 75
3 4/7 8/7 0.045 1.14 0.940 23.9 601 894 1193 541 13.2 334 95
3 3/7 6/7 0.045 1.14 0.990 25.1 721 1073 1622 736 13.9 352 115
3 2/7 6/7 0.045 1.14 1.040 26.4 891 1326 1922 872 14.6 370 130
4 14 14 0.030 0.76 0.490 12.4 130 193 131 60 6.9 174 20
4 12 14 0.030 0.76 0.535 13.6 166 247 209 95 7.5 190 24
4 10 12 0.030 0.76 0.630 16.0 232 345 332 150 8.8 224 32

 

ISO-AC90

Conductor

Count

Power

Conductor

Ins.Ground

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
AWG AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 14 0.030 0.76 0.440 11.2 105 156 66 30 6.2 157 25
2 12 12 14 0.030 0.76 0.485 12.3 138 206 104 47 6.8 173 30
2 10 10 12 0.030 0.76 0.533 13.5 186 277 166 75 7.5 190 40
3 12 12 14 0.030 0.76 0.535 13.6 165 245 157 71 7.5 190 24
3 10 10 12 0.030 0.76 0.591 15.0 232 346 249 113 8.3 210 32
CERTIFICATIONS

 

12/2 AC90 copper cable

PACKAGING

 

12/2 AC90 copper wire

Roll

12/2 copper AC90 cable

Plastic Reel

12/2 copper AC90 wire

Small Wooden Reel

APPLICATION

 

12/2 AC90 building wire
Apartment/Residential Building Electrical Distribution
12/2 AC90 building cable
Commercial Building Electrical Distribution
12/2 AC90 electrical cable
Industrial Factory Power Distribution
CASE

 

12/2 AC90 electrical wire

Calgary Alberta Multi Storey Apartment Construction Upgrade

12/2 AC90 metal clad cable

Toronto Ontario Detached House Basement Panel Upgrade

12/2 AC90 metal-clad cable

Vancouver British Columbia Downtown Office Renovation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

12/2 AC90 2 conductor cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

12/2 AC90 2 conductor wire
 
12/2 AC90 two conductor cable
 
12/2 AC90 black white cable
 
12/2 AC90 black white wire
 
12/2 AC90 RW90 cable
 
12/2 AC90 XLPE cable
 
GLOBAL CERTIFICATIONS

 

12/2 AC90 interlocked armoured cable

CUSTOMER PHOTOS
 

12/2 600V AC90 cable

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

12/2 AC90 aluminum armour cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

12/2 600V AC90 wire
12/2 cUL AC90 cable
12/2 CSA AC90 cable
12/2 AC90 cable for commercial wiring
12/2 AC90 cable for apartment wiring
12/2 AC90 cable supplier
12/2 AC90 cable manufacturer
12/2 AC90 cable for residential wiring
12/2 AC90 wholesale cable
12/2 AC90 factory direct cable
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

12/2 AC90 building wiring cable
FAQ

 

What voltage is AC90 cable rated for?
A standard 600V AC90 cable is designed for 600V building-wiring applications. The final circuit voltage, conductor loading, overcurrent protection and installation method should always comply with the product marking, project specification and local electrical code.
What is a 2 conductor AC90 cable?
A 2 conductor AC90 cable contains two insulated circuit conductors, typically identified by black and white insulation in this product configuration, plus the bonding conductor required by the cable design. The bonding conductor is not normally counted as one of the two circuit conductors.
What colors are used in a 2 conductor AC90 cable?
This AC90 black white cable configuration uses one black and one white insulated circuit conductor for clear field identification. Color conventions and circuit use should still follow the project design and local code requirements.
Is copper available for AC90 building wire?
Yes. copper AC90 wire uses copper circuit conductors for dependable conductivity and familiar termination practices. GERITEL WIRE can supply copper-conductor AC90 for B2B project, distributor and OEM-style requirements.

 

Hot Tags: 12/2 ac90 copper building wire 600v 2 conductor cul csa for receptacle wiring, China 12/2 ac90 copper building wire 600v 2 conductor cul csa for receptacle wiring manufacturers, suppliers, factory

Send Inquiry