10/2 AC90 Copper Armoured Wire 600V 2 Conductor CUL CSA For Higher Load Branch Circuits

10/2 AC90 Copper Armoured Wire 600V 2 Conductor CUL CSA For Higher Load Branch Circuits
Details:
·Conductor: Solid Soft Copper, ASTM B3
·Insulation: Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
·Colour Code: Black, White
·Bonding Conductor: Solid ASTM B3 Soft Bare Copper
·Armour: Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
·Voltage Rating: 600V
Send Inquiry
Download
Description
Technical Parameters
Certification

10/2 AC90 cable

PRODUCT REAL SHOT

 

10/2 AC90 wire
AC90 10/2 cable
AC90 10/2 wire

10/2 AC90 armoured cable

Heavier copper conductors for feeders equipment circuits and demanding indoor wiring
When a project requires a larger conductor for higher-current branch circuits or selected feeder applications, 10/2 AC90 cable provides copper conductors with RW90 XLPE insulation inside flexible interlocked aluminum armour. The 2 conductor black/white construction is suitable for dry indoor building wiring where 10 AWG is selected by the circuit design, including equipment feeds, longer branch runs and higher-load applications subject to code requirements. GERITEL WIRE supplies 10/2 AC90 armoured wire to contractors, distributors and project buyers with custom identification, packaging options, bulk production and repeat-order support. The 600V construction combines dependable electrical performance with mechanical protection for commercial, residential and light industrial interiors.
PRODUCT SPECIFICATIONS

 

10/2 AC90 armored cable

APPLICATIONS

 

Manufactured, tested and certified in Canada, GERITEL WIRE AC90 armoured building wire is rated FT4-ST1 for -40°C to 90°C. Engineered specifically for demanding environments, superior flammability and smoke emission performance.

For use in ventilated, non-ventilated and ladder-type cable trays.

For dry locations, in ceiling air-handling plenums, exposed or concealed wiring and service entrance above ground.

SPECIFICATIONS
Conductor Solid Soft Copper, ASTM B3
Insulation Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
Colour Code Black, White
Bonding Conductor Solid ASTM B3 Soft Bare Copper
Armour Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
Specifications and Compliance

CSA C22.2 No. 51, Armoured Cables (Type AC90)

CSA C22.2 No. 38 Thermoset-insulated wires and cables (Type RW90)

CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test

IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated

-40°C Cold Bend and -40°C Cold Impact

Limited Smoke and Halogen Free

AC90 & ISO-AC90 600V CSA FT4-ST1 LSZH

 

AC90

Power

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
Count AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 0.030 0.76 0.430 10.9 81 120 66 30 6.0 151 25
2 12 14 0.030 0.76 0.454 11.5 99 148 104 47 6.4 164 30
2 10 12 0.030 0.76 0.512 13.0 138 206 166 75 6.9 174 40
3 14 14 0.030 0.76 0.445 11.3 105 156 99 45 6.2 158 25
3 12 14 0.030 0.76 0.490 12.4 130 193 157 71 6.9 174 30
3 10 12 0.030 0.76 0.535 13.6 182 271 249 113 7.5 190 40
3 8/7 10 0.045 1.14 0.714 18.1 309 460 418 190 10.0 254 55
3 6/7 8/7 0.045 1.14 0.770 19.6 417 621 702 318 10.8 274 75
3 4/7 8/7 0.045 1.14 0.940 23.9 601 894 1193 541 13.2 334 95
3 3/7 6/7 0.045 1.14 0.990 25.1 721 1073 1622 736 13.9 352 115
3 2/7 6/7 0.045 1.14 1.040 26.4 891 1326 1922 872 14.6 370 130
4 14 14 0.030 0.76 0.490 12.4 130 193 131 60 6.9 174 20
4 12 14 0.030 0.76 0.535 13.6 166 247 209 95 7.5 190 24
4 10 12 0.030 0.76 0.630 16.0 232 345 332 150 8.8 224 32

 

ISO-AC90

Conductor

Count

Power

Conductor

Ins.Ground

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
AWG AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 14 0.030 0.76 0.440 11.2 105 156 66 30 6.2 157 25
2 12 12 14 0.030 0.76 0.485 12.3 138 206 104 47 6.8 173 30
2 10 10 12 0.030 0.76 0.533 13.5 186 277 166 75 7.5 190 40
3 12 12 14 0.030 0.76 0.535 13.6 165 245 157 71 7.5 190 24
3 10 10 12 0.030 0.76 0.591 15.0 232 346 249 113 8.3 210 32
CERTIFICATIONS

 

10/2 AC90 copper cable

PACKAGING

 

10/2 AC90 copper wire

Roll

10/2 copper AC90 cable

Plastic Reel

10/2 copper AC90 wire

Small Wooden Reel

APPLICATION

 

10/2 AC90 building wire
Apartment/Residential Building Electrical Distribution
10/2 AC90 building cable
Commercial Building Electrical Distribution
10/2 AC90 electrical cable
Industrial Factory Power Distribution
CASE

 

10/2 AC90 electrical wire

Calgary Alberta Multi Storey Apartment Construction Upgrade

10/2 AC90 metal clad cable

Toronto Ontario Detached House Basement Panel Upgrade

10/2 AC90 metal-clad cable

Vancouver British Columbia Downtown Office Renovation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

10/2 AC90 2 conductor cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

10/2 AC90 2 conductor wire
 
10/2 AC90 two conductor cable
 
10/2 AC90 black white cable
 
10/2 AC90 black white wire
 
10/2 AC90 RW90 cable
 
10/2 AC90 XLPE cable
 
GLOBAL CERTIFICATIONS

 

10/2 AC90 interlocked armoured cable

CUSTOMER PHOTOS
 

12/2 600V AC90 cable

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

10/2 AC90 aluminum armour cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

10/2 600V AC90 cable
10/2 600V AC90 wire
10/2 cUL AC90 cable
10/2 CSA AC90 cable
10/2 cUL CSA AC90 cable
10/2 AC90 branch circuit cable
10/2 AC90 building wiring cable
10/2 AC90 cable for lighting circuits
https://img01.v15cdn.com/modular/208/modular-9.webp
10/2 AC90 cable for apartment wiring
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

10/2 AC90 cable supplier
FAQ

 

Is AC90 considered building wire?
Yes. AC90 building wire is used as an armoured building-wiring method for suitable indoor circuits in commercial, residential, multi-residential and light industrial buildings. It is commonly selected where flexible routing and built-in mechanical protection are desirable.
Can AC90 cable replace conduit and individual wires?
In many permitted dry indoor applications, AC90 armoured building cable can reduce the need for a separate raceway plus individual conductors because the interlocked armour provides integrated mechanical protection. Whether it can replace conduit in a specific location depends on the electrical code, project specification and environmental conditions.
Is AC90 cable flexible?
Yes. flexible AC90 cable uses interlocked metallic armour that can bend for routing through building spaces more easily than rigid raceway systems. Minimum bend radius and installation practices should follow the manufacturer's data and applicable code.
Is AC90 suitable for permanent wiring?
AC90 electrical cable is intended for permanent building-wiring installations when installed in approved locations and according to electrical-code requirements. It is not a portable cord or temporary extension cable.

 

Hot Tags: 10/2 ac90 copper armoured wire 600v 2 conductor cul csa for higher load branch circuits, China 10/2 ac90 copper armoured wire 600v 2 conductor cul csa for higher load branch circuits manufacturers, suppliers, factory