600V 14/2 AC90 Copper Armoured Cable 2 Conductor CUL CSA For Lighting Circuits

600V 14/2 AC90 Copper Armoured Cable 2 Conductor CUL CSA For Lighting Circuits
Details:
·Conductor: Solid Soft Copper, ASTM B3
·Insulation: Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
·Colour Code: Black, White
·Bonding Conductor: Solid ASTM B3 Soft Bare Copper
·Armour: Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
·Voltage Rating: 600V
Send Inquiry
Download
Description
Technical Parameters
Certification

14/2 AC90 cable

PRODUCT REAL SHOT

 

14/2 AC90 wire
AC90 14/2 cable
AC90 14/2 cable

14/2 AC90 armoured cable

Light-duty branch circuit wiring for residential and commercial interiors
Designed for light-duty indoor branch circuits, 14/2 AC90 cable combines copper conductors, RW90 XLPE insulation, a bonding conductor and interlocked aluminum armour in a compact 600V construction. The 2 conductor black/white configuration is well suited to many lighting, control and general building-wiring applications where 14/2 is permitted by the local code and project design. For contractors, distributors and modular-building buyers sourcing 14 AWG AC90 wire, GERITEL WIRE supports bulk production, custom cable marking, project packaging and repeat-order planning. The flexible armoured structure helps simplify routing through wood framing, steel studs, ceilings and dry interior service spaces while providing integrated mechanical protection.
PRODUCT SPECIFICATIONS

 

14/2 AC90 armored cable

APPLICATIONS

 

Manufactured, tested and certified in Canada, GERITEL WIRE AC90 armoured building wire is rated FT4-ST1 for -40°C to 90°C. Engineered specifically for demanding environments, superior flammability and smoke emission performance.

For use in ventilated, non-ventilated and ladder-type cable trays.

For dry locations, in ceiling air-handling plenums, exposed or concealed wiring and service entrance above ground.

SPECIFICATIONS
Conductor Solid Soft Copper, ASTM B3
Insulation Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
Colour Code Black, White
Bonding Conductor Solid ASTM B3 Soft Bare Copper
Armour Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
Specifications and Compliance

CSA C22.2 No. 51, Armoured Cables (Type AC90)

CSA C22.2 No. 38 Thermoset-insulated wires and cables (Type RW90)

CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test

IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated

-40°C Cold Bend and -40°C Cold Impact

Limited Smoke and Halogen Free

AC90 & ISO-AC90 600V CSA FT4-ST1 LSZH

 

AC90

Power

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
Count AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 0.030 0.76 0.430 10.9 81 120 66 30 6.0 151 25
2 12 14 0.030 0.76 0.454 11.5 99 148 104 47 6.4 164 30
2 10 12 0.030 0.76 0.512 13.0 138 206 166 75 6.9 174 40
3 14 14 0.030 0.76 0.445 11.3 105 156 99 45 6.2 158 25
3 12 14 0.030 0.76 0.490 12.4 130 193 157 71 6.9 174 30
3 10 12 0.030 0.76 0.535 13.6 182 271 249 113 7.5 190 40
3 8/7 10 0.045 1.14 0.714 18.1 309 460 418 190 10.0 254 55
3 6/7 8/7 0.045 1.14 0.770 19.6 417 621 702 318 10.8 274 75
3 4/7 8/7 0.045 1.14 0.940 23.9 601 894 1193 541 13.2 334 95
3 3/7 6/7 0.045 1.14 0.990 25.1 721 1073 1622 736 13.9 352 115
3 2/7 6/7 0.045 1.14 1.040 26.4 891 1326 1922 872 14.6 370 130
4 14 14 0.030 0.76 0.490 12.4 130 193 131 60 6.9 174 20
4 12 14 0.030 0.76 0.535 13.6 166 247 209 95 7.5 190 24
4 10 12 0.030 0.76 0.630 16.0 232 345 332 150 8.8 224 32

 

ISO-AC90

Conductor

Count

Power

Conductor

Ins.Ground

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
AWG AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 14 0.030 0.76 0.440 11.2 105 156 66 30 6.2 157 25
2 12 12 14 0.030 0.76 0.485 12.3 138 206 104 47 6.8 173 30
2 10 10 12 0.030 0.76 0.533 13.5 186 277 166 75 7.5 190 40
3 12 12 14 0.030 0.76 0.535 13.6 165 245 157 71 7.5 190 24
3 10 10 12 0.030 0.76 0.591 15.0 232 346 249 113 8.3 210 32
CERTIFICATIONS

 

14/2 AC90 copper cable

PACKAGING

 

14/2 AC90 copper wire

Roll

14/2 copper AC90 cable

Plastic Reel

14/2 copper AC90 wire

Small Wooden Reel

APPLICATION

 

14/2 AC90 building wire
Apartment/Residential Building Electrical Distribution
14/2 AC90 building cable
Commercial Building Electrical Distribution
14/2 AC90 electrical cable
Industrial Factory Power Distribution
CASE

 

14/2 AC90 electrical wire

Calgary Alberta Multi Storey Apartment Construction Upgrade

14/2 AC90 metal clad cable

Toronto Ontario Detached House Basement Panel Upgrade

14/2 AC90 metal-clad cable

Vancouver British Columbia Downtown Office Renovation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

14/2 AC90 2 conductor cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

14/2 AC90 2 conductor wire
 
14/2 AC90 two conductor cable
 
14/2 AC90 black white cable
 
14/2 AC90 black white wire
 
14/2 AC90 RW90 cable
 
14/2 AC90 interlocked armoured cable
 
GLOBAL CERTIFICATIONS

 

14/2 600V AC90 cable

CUSTOMER PHOTOS
 

14/2 600V AC90 wire

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

14/2 cUL AC90 cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

14/2 CSA AC90 cable
14/2 cUL CSA AC90 cable
14/2 AC90 branch circuit cable
14/2 AC90 building wiring cable
14/2 AC90 cable for lighting circuits
14/2 AC90 cable for commercial wiring
14/2 AC90 cable supplier
14/2 AC90 cable manufacturer
14/2 AC90 wholesale cable
14/2 AC90 factory direct cable
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

14/2 AC90 cable for commercial wiring
FAQ

 

What is AC90 cable?
AC90 cable is a 600V armoured building cable widely used in Canadian electrical installations. A typical construction combines copper circuit conductors, RW90 XLPE insulation, a bonding conductor and flexible interlocked aluminum armour, giving the cable both electrical insulation and mechanical protection for suitable dry indoor wiring.
What does AC90 mean on an armoured cable?
The term AC90 armoured cable identifies a Canadian armoured building-cable type designed around insulated conductors inside interlocked metallic armour. The "90" is associated with the 90°C conductor temperature class of the insulated conductors; final ampacity and installation conditions must still follow the applicable code and product marking.
Is AC90 the same as BX cable?
In the Canadian trade, AC90 BX cable and "BX" are often used conversationally for similar-looking interlocked armoured building cable. AC90 is the more precise product designation for specifications, certification and procurement, so GERITEL WIRE recommends using AC90 on drawings and purchase documents.
Is AC90 a metal-clad cable?
AC90 metal-clad cable is commonly described in search and trade language as a metal-clad or metallic-armoured building cable because its insulated conductors are protected by interlocked metal armour. For Canadian project documentation, AC90 remains the preferred technical designation.

 

Hot Tags: 600v 14/2 ac90 copper armoured cable 2 conductor cul csa for lighting circuits, China 600v 14/2 ac90 copper armoured cable 2 conductor cul csa for lighting circuits manufacturers, suppliers, factory

Send Inquiry