AC90 Armored Cable Copper 600V For Retail Store Electrical Wiring

AC90 Armored Cable Copper 600V For Retail Store Electrical Wiring
Details:
·Conductor: Solid Soft Copper, ASTM B3
·Insulation: Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
·Colour Code: Black, White
·Bonding Conductor: Solid ASTM B3 Soft Bare Copper
·Armour: Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
·Voltage Rating: 600V
Send Inquiry
Download
Description
Technical Parameters
Certification

AC90 cable for branch circuit wiring

PRODUCT REAL SHOT

 

14/2 AC90 wire
AC90 14/2 cable
AC90 14/2 cable

AC90 wire for branch circuit wiring

Flexible protected wiring for shop fit-outs and branch circuits
Retail interiors need a wiring method that can be installed efficiently around partitions, ceilings and changing floor plans. AC90 armored cable provides copper conductors, RW90 XLPE insulation, a bonding conductor and interlocked aluminum armour in a flexible 600V construction for suitable dry-location applications. Its 2 conductor black/white configuration can support lighting, receptacle and general branch-circuit wiring throughout shops and commercial fit-outs. GERITEL WIRE manufactures AC90 cable for retail wiring for distributors, contractors and project procurement teams, with support for bulk orders, customized cable identification, packaging requirements and coordinated delivery schedules for multi-store rollouts and renovation programs.
PRODUCT SPECIFICATIONS

 

AC90 cable for branch circuit homeruns

APPLICATIONS

 

Manufactured, tested and certified in Canada, GERITEL WIRE AC90 armoured building wire is rated FT4-ST1 for -40°C to 90°C. Engineered specifically for demanding environments, superior flammability and smoke emission performance.

For use in ventilated, non-ventilated and ladder-type cable trays.

For dry locations, in ceiling air-handling plenums, exposed or concealed wiring and service entrance above ground.

SPECIFICATIONS
Conductor Solid Soft Copper, ASTM B3
Insulation Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
Colour Code Black, White
Bonding Conductor Solid ASTM B3 Soft Bare Copper
Armour Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
Specifications and Compliance

CSA C22.2 No. 51, Armoured Cables (Type AC90)

CSA C22.2 No. 38 Thermoset-insulated wires and cables (Type RW90)

CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test

IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated

-40°C Cold Bend and -40°C Cold Impact

Limited Smoke and Halogen Free

AC90 & ISO-AC90 600V CSA FT4-ST1 LSZH

 

AC90

Power

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
Count AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 0.030 0.76 0.430 10.9 81 120 66 30 6.0 151 25
2 12 14 0.030 0.76 0.454 11.5 99 148 104 47 6.4 164 30
2 10 12 0.030 0.76 0.512 13.0 138 206 166 75 6.9 174 40
3 14 14 0.030 0.76 0.445 11.3 105 156 99 45 6.2 158 25
3 12 14 0.030 0.76 0.490 12.4 130 193 157 71 6.9 174 30
3 10 12 0.030 0.76 0.535 13.6 182 271 249 113 7.5 190 40
3 8/7 10 0.045 1.14 0.714 18.1 309 460 418 190 10.0 254 55
3 6/7 8/7 0.045 1.14 0.770 19.6 417 621 702 318 10.8 274 75
3 4/7 8/7 0.045 1.14 0.940 23.9 601 894 1193 541 13.2 334 95
3 3/7 6/7 0.045 1.14 0.990 25.1 721 1073 1622 736 13.9 352 115
3 2/7 6/7 0.045 1.14 1.040 26.4 891 1326 1922 872 14.6 370 130
4 14 14 0.030 0.76 0.490 12.4 130 193 131 60 6.9 174 20
4 12 14 0.030 0.76 0.535 13.6 166 247 209 95 7.5 190 24
4 10 12 0.030 0.76 0.630 16.0 232 345 332 150 8.8 224 32

 

ISO-AC90

Conductor

Count

Power

Conductor

Ins.Ground

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
AWG AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 14 0.030 0.76 0.440 11.2 105 156 66 30 6.2 157 25
2 12 12 14 0.030 0.76 0.485 12.3 138 206 104 47 6.8 173 30
2 10 10 12 0.030 0.76 0.533 13.5 186 277 166 75 7.5 190 40
3 12 12 14 0.030 0.76 0.535 13.6 165 245 157 71 7.5 190 24
3 10 10 12 0.030 0.76 0.591 15.0 232 346 249 113 8.3 210 32
CERTIFICATIONS

 

AC90 wire for branch circuit homeruns

PACKAGING

 

AC90 cable for lighting circuits

Roll

AC90 wire for lighting circuits

Plastic Reel

AC90 cable for receptacle circuits

Small Wooden Reel

APPLICATION

 

AC90 wire for receptacle circuits
Apartment/Residential Building Electrical Distribution
AC90 cable for power outlet circuits
Commercial Building Electrical Distribution
AC90 wire for power outlet circuits
Industrial Factory Power Distribution
CASE

 

AC90 cable for ceiling fixture wiring

Calgary Alberta Multi Storey Apartment Construction Upgrade

AC90 wire for ceiling fixture wiring

Toronto Ontario Detached House Basement Panel Upgrade

AC90 cable for interior feeder wiring

Vancouver British Columbia Downtown Office Renovation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

AC90 wire for interior feeder wiring
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

AC90 cable for building power distribution
 
AC90 wire for building power distribution
 
AC90 cable for electrical distribution
 
AC90 wire for electrical distribution
 
AC90 cable for open wiring
 
AC90 wire for open wiring
 
GLOBAL CERTIFICATIONS

 

AC90 cable for concealed wiring

CUSTOMER PHOTOS
 

AC90 wire for concealed wiring

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

AC90 cable for exposed interior wiring
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

AC90 wire for exposed interior wiring
AC90 cable for above ceiling wiring
AC90 wire for above ceiling wiring
AC90 cable for ceiling space wiring
AC90 wire for ceiling space wiring
AC90 cable for service space wiring
AC90 wire for service space wiring
AC90 wire for cable trough wiring
AC90 cable for ventilated cableway wiring
AC90 wire for ventilated cableway wiring
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

AC90 cable for cable tray wiring in dry locations
FAQ

 

What temperature class does AC90 insulation support?
A typical 90C AC90 cable uses RW90 insulation associated with a 90°C conductor temperature class. Allowable ampacity can still be limited by terminals, installation conditions, bundling, ambient temperature and code rules.
Is the inner insulation moisture resistant?
The individual conductors in RW90 insulated AC90 cable use RW90 insulation with wet-rated insulation characteristics. However, the complete standard AC90 cable assembly is generally intended for dry-location installation, so the whole-cable location rating must not be inferred from conductor insulation alone.
Can AC90 be manufactured with custom printing?
Yes. For qualified B2B orders, custom AC90 cable marking can be produced with project or customer-specific identification subject to certification and marking rules. GERITEL WIRE can discuss print content, packaging labels and production documentation before manufacturing.
What makes AC90 different from ACWU90 construction?
AC90 vs ACWU90 mainly differs in environmental protection. Standard AC90 is a dry-location armoured building cable, while ACWU90 includes additional jacketed protection intended for wet or more demanding locations, subject to the specific certified construction.

 

Hot Tags: ac90 armored cable copper 600v for retail store electrical wiring, China ac90 armored cable copper 600v for retail store electrical wiring manufacturers, suppliers, factory, ac cable, AC Power Cable

Send Inquiry