CUL CSA AC90 Copper Wire 600V 2 Conductor Black Red

CUL CSA AC90 Copper Wire 600V 2 Conductor Black Red
Details:
·Conductor: Solid Soft Copper, ASTM B3
·Insulation: Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
·Colour Code: Black, Red
·Bonding Conductor: Solid ASTM B3 Soft Bare Copper
·Armour: Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
·Voltage Rating: 600V
Send Inquiry
Download
Description
Technical Parameters
Certification

Dongguan Greater Wire & Cable Co., Ltd. is one of the leading manufacturers and suppliers of cul csa ac90 copper wire 600v 2 conductor black red in China, also supports customized service. Please rest assured to wholesale durable cul csa ac90 copper wire 600v 2 conductor black red made in China here from our factory. If you have any enquiry about free sample, please feel free to email us.

 

AC90 copper bond wire

PRODUCT REAL SHOT

 

AC90 aluminum armour cable
AC90 aluminium armour cable
AC90 interlocked armor wire

AC90 interlocked armour wire

Certified-style armoured construction for Canadian electrical projects
Designed around the needs of Canadian building projects, cUL AC90 cable combines electrical performance and mechanical protection in a compact armoured construction. The cable uses copper conductors, RW90 XLPE insulation, paper wrap, a bonding conductor and interlocked aluminum armour, with Black/Red identification for the two circuit conductors. This 600V design supports suitable dry indoor branch-circuit applications and helps installers route cable efficiently through framed interiors and service areas. GERITEL WIRE manufactures CSA AC90 wire for B2B customers requiring stable quality, custom markings, packaging options and coordinated project supply. Final application should always follow the current product marking, project specification and applicable electrical code.
PRODUCT SPECIFICATIONS

 

Canadian AC90 wire

APPLICATIONS

 

Manufactured, tested and certified in Canada, GERITEL WIRE AC90 armoured building wire is rated FT4-ST1 for -40°C to 90°C. Engineered specifically for demanding environments, superior flammability and smoke emission performance.

Designed for Single-Phase Heating Installations.

For use in ventilated, non-ventilated and ladder-type cable trays.

For dry locations, in ceiling air-handling plenums, exposed or concealed wiring and service entrance above ground.

SPECIFICATIONS
Conductor Solid Soft Copper, ASTM B3
Insulation Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
Colour Code Black, Red
Bonding Conductor Solid ASTM B3 Soft Bare Copper
Armour Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
Specifications and Compliance

CSA C22.2 No. 51, Armoured Cables (Type AC90)

CSA C22.2 No. 38 Thermoset-insulated wires and cables (Type RW90)

CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test

IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated

-40°C Cold Bend and -40°C Cold Impact

Limited Smoke and Halogen Free

AC90 & ISO-AC90 600V CSA FT4-ST1 LSZH

 

AC90

Power

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
Count AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 0.030 0.76 0.430 10.9 81 120 66 30 6.0 151 25
2 12 14 0.030 0.76 0.454 11.5 99 148 104 47 6.4 164 30
2 10 12 0.030 0.76 0.512 13.0 138 206 166 75 6.9 174 40
3 14 14 0.030 0.76 0.445 11.3 105 156 99 45 6.2 158 25
3 12 14 0.030 0.76 0.490 12.4 130 193 157 71 6.9 174 30
3 10 12 0.030 0.76 0.535 13.6 182 271 249 113 7.5 190 40
3 8/7 10 0.045 1.14 0.714 18.1 309 460 418 190 10.0 254 55
3 6/7 8/7 0.045 1.14 0.770 19.6 417 621 702 318 10.8 274 75
3 4/7 8/7 0.045 1.14 0.940 23.9 601 894 1193 541 13.2 334 95
3 3/7 6/7 0.045 1.14 0.990 25.1 721 1073 1622 736 13.9 352 115
3 2/7 6/7 0.045 1.14 1.040 26.4 891 1326 1922 872 14.6 370 130
4 14 14 0.030 0.76 0.490 12.4 130 193 131 60 6.9 174 20
4 12 14 0.030 0.76 0.535 13.6 166 247 209 95 7.5 190 24
4 10 12 0.030 0.76 0.630 16.0 232 345 332 150 8.8 224 32

 

ISO-AC90

Conductor

Count

Power

Conductor

Ins.Ground

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
AWG AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 14 0.030 0.76 0.440 11.2 105 156 66 30 6.2 157 25
2 12 12 14 0.030 0.76 0.485 12.3 138 206 104 47 6.8 173 30
2 10 10 12 0.030 0.76 0.533 13.5 186 277 166 75 7.5 190 40
3 12 12 14 0.030 0.76 0.535 13.6 165 245 157 71 7.5 190 24
3 10 10 12 0.030 0.76 0.591 15.0 232 346 249 113 8.3 210 32
CERTIFICATIONS

 

Canada AC90 cable

PACKAGING

 

Canada AC90 wire

Roll

AC90 cable Canada

Plastic Reel

AC90 wire Canada

Small Wooden Reel

APPLICATION

 

AC90 armoured cable Canada
Apartment/Residential Building Electrical Distribution
AC90 armored cable Canada
Commercial Building Electrical Distribution
AC90 building wire Canada
Industrial Factory Power Distribution
CASE

 

AC90 copper cable Canada

Calgary Alberta Multi Storey Apartment Construction Upgrade

AC90 copper wire Canada

Toronto Ontario Detached House Basement Panel Upgrade

CSA AC90 cable

Vancouver British Columbia Downtown Office Renovation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

CSA AC90 wire
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

CSA AC90 armoured cable
 
CSA AC90 building wire
 
cUL AC90 cable
 
cUL AC90 wire
 
cUL CSA AC90 cable
 
cUL CSA AC90 wire
 
GLOBAL CERTIFICATIONS

 

AC90 BX cable

CUSTOMER PHOTOS
 

AC90 BX wire

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

BX AC90 cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

BX AC90 wire
AC90 copper BX cable
AC90 copper BX wire
BX armoured cable AC90
BX armored cable AC90
Canadian BX cable AC90
Canadian BX wire AC90
AC90 BX building wire
AC90 BX building cable
AC90 A90 cable
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

A90 armoured cable
FAQ

 

What is the paper wrap inside AC90 for?
Paper wrapped AC90 cable uses a binder or wrap to organize and separate the conductor assembly before the metallic armour is applied. It helps maintain the internal cable structure during manufacturing and installation.
Is AC90 mechanically protected?
Yes. Mechanically protected AC90 cable uses interlocked metallic armour around the insulated conductors. The armour helps protect against normal installation and service stresses, but it does not make the cable immune to crushing or severe impact.
Does AC90 use bare aluminum armour?
Standard bare aluminium armour AC90 typically has the metallic armour exposed as the outer cable surface. This differs from jacketed armoured cables designed for wet or more severe environments.
Can Black/Red AC90 use solid copper conductors?
Solid copper AC90 may be available in certain conductor sizes and certified constructions. The conductor type should be verified for the specific size ordered.
 

 

Hot Tags: cul csa ac90 copper wire 600v 2 conductor black red, China cul csa ac90 copper wire 600v 2 conductor black red manufacturers, suppliers, factory

Send Inquiry