ACWU90 Direct Burial Aluminum Armored Cable For Approved Routes

ACWU90 Direct Burial Aluminum Armored Cable For Approved Routes
Details:
·Conductor: 8000 series compact-stranded aluminum alloy
·Insulation: XLPE. Thickness per CSA C22.2 No. 51
·Armor: Aluminum interlocked armour(AIA)
·Jacket: Flame retardant PVC jacket
·Voltage Rating: 600V
·Rated temperature: 90°C
·Flame test rating: FT4
·Low temperatue classification: -40°C
·Application: Commercial Building Power Distribution、Residential Building Electrical Feeders、Industrial Manufacturing Plants、Underground Power Distribution、Building Service Entrance Installations、Electrical Distribution Panels...
Send Inquiry
Download
Description
Technical Parameters
Certification

Dongguan Greater Wire & Cable Co., Ltd. is one of the leading manufacturers and suppliers of acwu90 direct burial aluminum armored cable for approved routes in China, also supports customized service. Please rest assured to wholesale durable acwu90 direct burial aluminum armored cable for approved routes made in China here from our factory. If you have any enquiry about free sample, please feel free to email us.

 

ACWU90 Aluminum Armoured Cable for data center low voltage AC feeders

PRODUCT REAL SHOT

 

ACWU90 Aluminum Armoured Cable for server facility distribution feeders

 

ACWU90 Aluminum Armoured Cable for battery energy storage site AC feeders
ACWU90 Aluminum Armoured Cable for BESS auxiliary AC power distribution

ACWU90 Aluminum Armoured Cable for solar plant AC distribution feeders

Underground routes require product and installation approval
Underground routes involve soil conditions, installation depth, backfill and entry protection that no catalogue title can settle by itself. ACWU90 Direct Burial Aluminum Armored Cable is used in direct-burial applications where its listing and local rules permit, benefiting from an interlocked aluminum armour beneath a PVC outer jacket. Inside are 600V RW90 XLPE-insulated aluminum alloy conductors. GERITEL WIRE invites contractors to share route length, burial method, termination arrangement and the required Canadian certification scope. We can then discuss suitable supply configuration and reel logistics. The design professional remains responsible for checking burial suitability, protection at transitions and overall installation compliance.
PRODUCT SPECIFICATIONS

 

ACWU90 Aluminum Armoured Cable for solar inverter station AC feeders

Scope

 

This specification covers three or four compact-stranded 8000 series aluminum alloy conductors with cross-linked polyethylene (XLPE) insulation plus one bare aluminum alloy bonding conductor in multi-conductor cables. Conductor assembly is wrapped and enclosed in interlocked aluminum armour with flame retardant PVC jacket.Type ACWU90 cable is conforming to CSA C22.2 No. 51 standard .cUL file No.E544860.

Application

 

Type ACWU90 cables are primarily intended for exposed and concealed wiring in dry or wet locations and where exposed to the weather. For use in ventilated, non-ventilated, and ladder type cable trays in wet and dry locations; direct earth burial; service entrance above or below ground.

SPECIFICATIONS
Conductor 8000 series compact-stranded aluminum alloy
Insulation XLPE. Thickness per CSA C22.2 No. 51
Color Coding

For 3 conductors construction: Black, red and blue plus bare bonding conductor.Or black, red and white plus bare bonding conductor.

For 4 conductors construction: Black, red, blue and white plus bare bonding conductor.

Bonding Conductor One bare 8000 series compact-stranded aluminum alloy.
Cabling

Three or four insulated conductors plus one bare bonding conductor are assembled without fillers and wrapped by a PP tape.

Armour Aluminum interlocked armour(AIA)
Jacket Flame retardant PVC jacket
Rated Voltage

600V 

Rated Temperature 90°C
Low Temperatue Classification -40°C
Flame Test Rating FT4

Type ACWU90 Cable Data

(AA 8000 series alloy conductor)

SIZE
(AWG/kcmil)

Strands

No./O.D.

(mm)

XLPE

Insulation

Average

Thickness

(mm)

PVC

Jacket

Average

Thickness

(mm)

Approx.

O.D.

(mm)

Max.DC

Resistance

(20°C,Ω/km)

Approx.

Weight

(kg/km)

3 x 6+8

7/1.60

7/1.28

0.76 1.14 21.44 2.211/3.515 469.49
3 x 4+6

7/2.02

7/1.60

1.02 1.14 24.84 1.390/2.211 630.58
3 x 2+6

7/2.58

7/1.60

1.02 1.14 30.68 0.8745/2.211 805.92
3 x 1+4

18/1.82

7/2.02

1.27 1.14 33.61 0.6934/1.390 980.49
3 x 1/0+4

18/2.02

7/2.02

1.27 1.14 35.51 0.5498/1.390 1112.91
3 x 2/0+4

18/2.32

7/2.02

1.27 1.14 37.24 0.4361/1.390 1267.50
3 x 3/0+4

18/2.58

7/2.02

1.27 1.14 39.32 0.3459/1.390 1459.66
3 x 4/0+4

18/2.83

7/2.02

1.27 1.14 41.86 0.2743/1.390 1699.24
3 x 250+2

36/2.22

7/2.58

1.52 1.14 45.65 0.2322/0.8745 2008.08
3 x 300+2

36/2.42

7/2.58

1.52 1.14 47.92 0.1935/0.8745 2268.74
3 x 350+2

36/2.58

7/2.58

1.52 1.14 51.11 0.1659/0.8745 2623.71
3 x 400+2

36/2.74

7/2.58

1.52 1.14 53.29 0.1450/0.8745 2894.90
3 x 500+2

36/3.10

18/1.82

1.52 1.14 57.01 0.1161/0.6934 3420.76
3 x 600+2

58/2.65

18/1.82

1.52 1.50 61.40 0.09673/0.6934 4038.83
3 x 750+1/0

58/2.98

18/2.02

1.52 1.50 66.21 0.07738/0.5498 4823.16
4 x 6+8

7/1.60

7/1.28

0.76 1.14 23.29 2.211/3.515 549.68
4 x 4+6

7/2.02

7/1.60

1.02 1.14 27.15 1.390/2.211 749.09
4 x 2+6

7/2.58

7/1.60

1.02 1.14 33.48 0.8745/2.211 970.96
4 x 1+4

18/1.82

7/2.02

1.27 1.14 36.78 0.6934/1.390 1186.84
4 x 1/0+4

18/2.02

7/2.02

1.27 1.14 39.05 0.5498/1.390 1358.96
4 x 2/0+4

18/2.32

7/2.02

1.27 1.14 41.10 0.4361/1.390 1561.06
4 x 3/0+4

18/2.58

7/2.02

1.27 1.14 43.59 0.3459/1.390 1812.41
4 x 4/0+4

18/2.83

7/2.02

1.27 1.14 46.61 0.2743/1.390 2125.94
4 x 250+2

36/2.22

7/2.58

1.52 1.14 51.96 0.2322/0.8745 2615.19
4 x 300+2

36/2.42

7/2.58

1.52 1.14 54.66 0.1935/0.8745 2963.18
4 x 350+2

36/2.58

7/2.58

1.52 1.14 57.15 0.1659/0.8745 3303.61
4 x 400+2

36/2.74

7/2.58

1.52 1.14 60.50 0.1450/0.8745 3763.51
4 x 500+2

36/3.10

18/1.82

1.52 1.50 64.79 0.1161/0.6934 4451.79
4 x 600+2

58/2.65

18/1.82

1.52 1.50 69.11 0.09673/0.6934 5133.01
4 x 750+1/0

58/2.98

18/2.02

1.52 1.50 74.65 0.07738/0.5498 6151.02
CERTIFICATIONS

 

ACWU90 Aluminum Armoured Cable for wind farm auxiliary AC feeders

PACKAGING

 

ACWU90 Cable with AA 8000 aluminum alloy conductors

Roll

ACWU90 Wire with AA 8000 aluminum alloy conductors

Small Wooden Reel

4 Conductor ACWU90 Cable with AA 8000 aluminum alloy conductors

Large Wooden Reel

APPLICATION

 

ACWU90 AA-8000 Aluminum Alloy Cable
Battery Energy Storage System (BESS) AC Power Distribution
ACWU90 AA-8000 Aluminum Alloy Wire
Commercial Building Power Distribution
600V ACWU90 AA-8000 Aluminum Alloy Cable
Industrial Manufacturing Plant Power Distribution
CASE

 

ACWU90 Aluminum Armoured Cable AA-8000 Aluminum Alloy

Garden Bay Water Treatment Plant Generator Replacement

ACWU90 Cable for factory expansions

Sechelt Aquatic Centre Lighting Upgrade

ACWU90 Cable for building service entrances

Watson Lake Recreation Centre Change Room Renovation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

ACWU90 Cable for commercial power feeders
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

ACWU90 Cable for industrial power feeders
 
ACWU90 Cable for building branch circuits
 
ACWU90 Cable for electrical rooms
 
ACWU90 Cable for low voltage power distribution
 
ACWU90 Cable for utility buildings
 
ACWU90 Cable for outdoor electrical installations
 
GLOBAL CERTIFICATIONS

 

ACWU90 Cable with stranded aluminum conductors

CUSTOMER PHOTOS
 

ACWU90 Wire with stranded aluminum conductors

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

4 Conductor ACWU90 Cable with stranded aluminum conductors
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

ACWU90 Cable for motor control center feeders
ACWU90 Cable for electrical panel feeders
ACWU90 Cable for prefabricated building service feeders
ACWU90 Cable for hotels
ACWU90 Multiconductor Wire
ACWU90 Cable for integrated housing electrical feeders
ACWU90 Cable for modular building power feeders
ACWU90 Cable for water treatment plants
ACWU90 Cable for wastewater treatment plants
ACWU90 Four Core Aluminum Wire
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

ACWU90 Stranded Aluminum Cable
FAQ

 

Can ACWU90 be supplied for Canadian importers?
GERITEL WIRE works with customers evaluating ACWU90 cable supplier for Canada for the Canadian market. Importers should independently review customs, labeling and certification requirements for their orders.
Can a buyer request an ACWU90 technical data sheet?
Request the current ACWU90 cable technical data sheet sheet for the exact size and construction being quoted. It should identify the relevant ratings, materials and manufacturer information.
Can cable markings be customized for an OEM buyer?
OEM marking on ACWU90 cable OEM marking must remain consistent with certification and labeling rules. GERITEL WIRE can discuss permitted production and branding requirements during technical review.
How can an EPC contractor request an ACWU90 quotation?
For ACWU90 EPC project cable, provide the circuit schedule, destination market, certification scope, preferred packing and target delivery. This allows a relevant technical and commercial response.

 

Hot Tags: acwu90 direct burial aluminum armored cable for approved routes, China acwu90 direct burial aluminum armored cable for approved routes manufacturers, suppliers, factory

Send Inquiry