CSA ACWU90 4 Conductor Cable For Commercial Power Distribution

CSA ACWU90 4 Conductor Cable For Commercial Power Distribution
Details:
·Conductor: 8000 series compact-stranded aluminum alloy
·Insulation: XLPE. Thickness per CSA C22.2 No. 51
·Armor: Aluminum interlocked armour(AIA)
·Jacket: Flame retardant PVC jacket
·Voltage Rating: 600V
·Rated temperature: 90°C
·Flame test rating: FT4
·Low temperatue classification: -40°C
·Application: Commercial Building Power Distribution、Residential Building Electrical Feeders、Industrial Manufacturing Plants、Underground Power Distribution、Building Service Entrance Installations、Electrical Distribution Panels...
Send Inquiry
Download
Description
Technical Parameters
Certification

Dongguan Greater Wire & Cable Co., Ltd. is one of the leading manufacturers and suppliers of csa acwu90 4 conductor cable for commercial power distribution in China, also supports customized service. Please rest assured to wholesale durable csa acwu90 4 conductor cable for commercial power distribution made in China here from our factory. If you have any enquiry about free sample, please feel free to email us.

 

600V ACWU90 Power Cable for industrial power feeders

PRODUCT REAL SHOT

 

600V ACWU90 Power Cable for building branch circuits

 

600V ACWU90 Power Cable for electrical rooms
600V ACWU90 Power Cable for low voltage power distribution

600V ACWU90 Power Cable for utility buildings

Documentation led selection for Canadian project submittals
For a commercial project, the words CSA ACWU90 4 Conductor Cable should lead to a documentation check, not an assumption about every possible rating. GERITEL WIRE supports buyers evaluating 600V aluminum armoured feeders with XLPE insulation and a PVC jacket for building power distribution. The relevant certificate scope, conductor configuration and markings should be verified for the exact supplied product. Our factory team can coordinate datasheets, identification details, packaging plans and shipment records so procurement departments have consistent documents for submittal and receiving. This approach is particularly useful when electrical equipment, contractor schedules and compliance reviews must move together.
PRODUCT SPECIFICATIONS

 

ACWU90 2 AWG 4C Armored Wire

Scope

 

This specification covers three or four compact-stranded 8000 series aluminum alloy conductors with cross-linked polyethylene (XLPE) insulation plus one bare aluminum alloy bonding conductor in multi-conductor cables. Conductor assembly is wrapped and enclosed in interlocked aluminum armour with flame retardant PVC jacket.Type ACWU90 cable is conforming to CSA C22.2 No. 51 standard .cUL file No.E544860.

Application

 

Type ACWU90 cables are primarily intended for exposed and concealed wiring in dry or wet locations and where exposed to the weather. For use in ventilated, non-ventilated, and ladder type cable trays in wet and dry locations; direct earth burial; service entrance above or below ground.

SPECIFICATIONS
Conductor 8000 series compact-stranded aluminum alloy
Insulation XLPE. Thickness per CSA C22.2 No. 51
Color Coding

For 3 conductors construction: Black, red and blue plus bare bonding conductor.Or black, red and white plus bare bonding conductor.

For 4 conductors construction: Black, red, blue and white plus bare bonding conductor.

Bonding Conductor One bare 8000 series compact-stranded aluminum alloy.
Cabling

Three or four insulated conductors plus one bare bonding conductor are assembled without fillers and wrapped by a PP tape.

Armour Aluminum interlocked armour(AIA)
Jacket Flame retardant PVC jacket
Rated Voltage

600V 

Rated Temperature 90°C
Low Temperatue Classification -40°C
Flame Test Rating FT4

Type ACWU90 Cable Data

(AA 8000 series alloy conductor)

SIZE
(AWG/kcmil)

Strands

No./O.D.

(mm)

XLPE

Insulation

Average

Thickness

(mm)

PVC

Jacket

Average

Thickness

(mm)

Approx.

O.D.

(mm)

Max.DC

Resistance

(20°C,Ω/km)

Approx.

Weight

(kg/km)

3 x 6+8

7/1.60

7/1.28

0.76 1.14 21.44 2.211/3.515 469.49
3 x 4+6

7/2.02

7/1.60

1.02 1.14 24.84 1.390/2.211 630.58
3 x 2+6

7/2.58

7/1.60

1.02 1.14 30.68 0.8745/2.211 805.92
3 x 1+4

18/1.82

7/2.02

1.27 1.14 33.61 0.6934/1.390 980.49
3 x 1/0+4

18/2.02

7/2.02

1.27 1.14 35.51 0.5498/1.390 1112.91
3 x 2/0+4

18/2.32

7/2.02

1.27 1.14 37.24 0.4361/1.390 1267.50
3 x 3/0+4

18/2.58

7/2.02

1.27 1.14 39.32 0.3459/1.390 1459.66
3 x 4/0+4

18/2.83

7/2.02

1.27 1.14 41.86 0.2743/1.390 1699.24
3 x 250+2

36/2.22

7/2.58

1.52 1.14 45.65 0.2322/0.8745 2008.08
3 x 300+2

36/2.42

7/2.58

1.52 1.14 47.92 0.1935/0.8745 2268.74
3 x 350+2

36/2.58

7/2.58

1.52 1.14 51.11 0.1659/0.8745 2623.71
3 x 400+2

36/2.74

7/2.58

1.52 1.14 53.29 0.1450/0.8745 2894.90
3 x 500+2

36/3.10

18/1.82

1.52 1.14 57.01 0.1161/0.6934 3420.76
3 x 600+2

58/2.65

18/1.82

1.52 1.50 61.40 0.09673/0.6934 4038.83
3 x 750+1/0

58/2.98

18/2.02

1.52 1.50 66.21 0.07738/0.5498 4823.16
4 x 6+8

7/1.60

7/1.28

0.76 1.14 23.29 2.211/3.515 549.68
4 x 4+6

7/2.02

7/1.60

1.02 1.14 27.15 1.390/2.211 749.09
4 x 2+6

7/2.58

7/1.60

1.02 1.14 33.48 0.8745/2.211 970.96
4 x 1+4

18/1.82

7/2.02

1.27 1.14 36.78 0.6934/1.390 1186.84
4 x 1/0+4

18/2.02

7/2.02

1.27 1.14 39.05 0.5498/1.390 1358.96
4 x 2/0+4

18/2.32

7/2.02

1.27 1.14 41.10 0.4361/1.390 1561.06
4 x 3/0+4

18/2.58

7/2.02

1.27 1.14 43.59 0.3459/1.390 1812.41
4 x 4/0+4

18/2.83

7/2.02

1.27 1.14 46.61 0.2743/1.390 2125.94
4 x 250+2

36/2.22

7/2.58

1.52 1.14 51.96 0.2322/0.8745 2615.19
4 x 300+2

36/2.42

7/2.58

1.52 1.14 54.66 0.1935/0.8745 2963.18
4 x 350+2

36/2.58

7/2.58

1.52 1.14 57.15 0.1659/0.8745 3303.61
4 x 400+2

36/2.74

7/2.58

1.52 1.14 60.50 0.1450/0.8745 3763.51
4 x 500+2

36/3.10

18/1.82

1.52 1.50 64.79 0.1161/0.6934 4451.79
4 x 600+2

58/2.65

18/1.82

1.52 1.50 69.11 0.09673/0.6934 5133.01
4 x 750+1/0

58/2.98

18/2.02

1.52 1.50 74.65 0.07738/0.5498 6151.02
CERTIFICATIONS

 

600V ACWU90 Power Cable for underground feeders

PACKAGING

 

600V ACWU90 Power Cable for cable tray systems

Roll

600V ACWU90 Power Cable for switchgear feeders

Small Wooden Reel

600V ACWU90 Power Cable for motor control center feeders

Large Wooden Reel

APPLICATION

 

600V ACWU90 Power Cable for electrical panel feeders
Battery Energy Storage System (BESS) AC Power Distribution
600V ACWU90 Power Cable for prefabricated building service feeders
Commercial Building Power Distribution
ACWU90 RW90 Wire
Industrial Manufacturing Plant Power Distribution
CASE

 

Aluminum Armoured Power Cable ACWU90

Garden Bay Water Treatment Plant Generator Replacement

600V ACWU90 Power Cable for modular building power feeders

Sechelt Aquatic Centre Lighting Upgrade

ACWU90 Aluminum Armoured Power Cable

Watson Lake Recreation Centre Change Room Renovation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

600V ACWU90 Power Cable for integrated housing electrical feeders
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

XLPE Insulated Aluminum Wire ACWU90
 
XLPE Insulated Aluminum Cable ACWU90
 
ACWU90 XLPE Insulated Aluminum Cable
 
ACWU90 XLPE Insulated Aluminum Wire
 
Jacketed Aluminum Armoured Cable ACWU90
 
Jacketed Aluminum Armoured Wire ACWU90
 
GLOBAL CERTIFICATIONS

 

600V ACWU90 Power Cable for manufactured housing service connections

CUSTOMER PHOTOS
 

600V ACWU90 Power Cable for data center low voltage AC feeders

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

600V ACWU90 Power Cable for server facility distribution feeders
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

ACWU90 Armored Power Wire
Interlocked Aluminum Armoured Wire ACWU90
ACWU90 Interlocked Aluminum Armoured Cable
ACWU90 Multiconductor Cable
ACWU90 Multiconductor Wire
ACWU90 Multicore Cable
ACWU90 Interlocked Aluminum Armoured Wire
4 Conductor Aluminum Armoured Cable ACWU90
ACWU90 4C Aluminum Cable
ACWU90 4C Aluminum Wire
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

600V ACWU90 Power Cable for battery energy storage site AC feeders
FAQ

 

Can ACWU90 be installed at healthcare facilities?
ACWU90 hospital feeder cable may be relevant to certain normal building feeders, but hospital essential electrical systems can impose special requirements. Qualified designers must confirm each application.
Could ACWU90 be used in retail shopping centers?
ACWU90 retail building wire may be specified for suitable permanent low-voltage distribution in shopping centers. Circuit duty, conductor sizing and equipment connections govern the actual choice.
Does ACWU90 work for mining site electrical buildings?
ACWU90 mining facility feeder cable may be assessed for approved building-side AC distribution at mining support facilities. Mine-specific codes, environmental hazards and installation approvals require separate verification.
How do engineers select ACWU90 conductor size?
Select ACWU90 cable sizing using design current, allowable ampacity, voltage drop, fault conditions and terminal ratings under the applicable code. Physical size alone cannot establish suitability.

 

Hot Tags: csa acwu90 4 conductor cable for commercial power distribution, China csa acwu90 4 conductor cable for commercial power distribution manufacturers, suppliers, factory

Send Inquiry