EV Charging Station Internal Control Wire – EN 50525-2-31 Flexible PVC Solution

EV Charging Station Internal Control Wire – EN 50525-2-31 Flexible PVC Solution
Details:
·Conductor: Class 5 flexible copper conductor
·Insulation: PVC (Polyvinyl Chloride)
·Voltage Rating Uo/U: H05V-K:300/500V ; H07V-K:450/750V
·Temperature Rating: Fixed: -30°C to +70℃ ; Flexed: -5°C to +70℃
·Standards: EN 50525-2-31, EN 60228 ; Flame Retardant according to IEC/EN 60332-1-2 ; UV Resistant
Send Inquiry
Download
Description
Technical Parameters
Certification

instrumentation panel wire manufacturer

PRODUCT REAL SHOT

 

instrumentation panel panel wire supplier
instrumentation panel internal wire supplier
instrumentation panel H05V-K supplier

control cabinet wire supplier

H05V-K wire for EV charger cabinets for Efficient Panel Production and Terminal Work
H05V-K uses a fine-stranded Class 5 copper conductor with PVC insulation for protected control, relay and auxiliary circuits inside EV charging equipment. This page targets searches for EV charger panel wire, charging equipment internal wire and 300/500V cabinet wire while keeping the technical product definition consistent. this page targets internal control wiring and should not imply use as the vehicle charging cable itself. The wire is intended for suitable fixed or protected internal use, so final selection should follow the equipment drawing, voltage, installation method and local rules. GERITEL WIRE can confirm construction, colour and packing details before volume production.
PRODUCT SPECIFICATIONS

 

control cabinet wire manufacturer

Applications

 

PVC panel wiring for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.

SPECIFICATIONS
Voltage Rating Uo/U

H05V-K:300/500V

H07V-K:450/750V

Temperature Rating

Fixed: -30°C to +70°C

Flexed: -5°C to +70°C

Minimum Bending Radius Fixed: 6 x overall diameter
Conductor Class 5 flexible copper conductor
Insulation PVC (Polyvinyl Chloride)
Insulation Colour Red,Black,Blue,Orange,Yellow,White,Green/Yellow,Violet,Pink,Grey,Brown
STANDARDS

EN 50525-2-31,EN 60228

Flame Retardant according to IEC/EN 60332-1-2

UV Resistant

DIMENSIONS

NOMINAL CROSS SECTIONAL AREA

mm²

NOMINAL OVERALL DIAMETER

mm²

NOMINAL WEIGHT

kg/km

H05V-K
0.5 2.20 9.1
0.75 2.40 11.7
1 2.55 14.4
H07V-K
1.5 3.00 20.1
2.5 3.65 31.5
4 4.20 46.2
6 4.80 65.1
10 6.25 109.4
16 7.40 165.2
25 9.40 253.4
35 10.40 345.5
50 12.55 492.4
70 14.10 669.3
95 17.20 910.4
120 17.70 1129.4
150 19.60 1401.0
185 23.00 1741.0
240 26.40 2267.5

CONDUCTORS

NOMINAL CROSS

SECTIONAL AREA

mm²

MAXIMUM DIAMETER

OF WIRES IN CONDUCTOR

mm

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Plain Wires
0.5 0.21 39
0.75 0.21 26
1 0.21 19.5
1.5 0.26 13.3
2.5 0.26 7.98
4 0.31 4.95
6 0.31 3.3
10 0.41 1.91
16 0.41 1.21
25 0.41 0.78
35 0.41 0.554
50 0.41 0.386
70 0.51 0.272
95 0.51 0.206
120 0.51 0.161
150 0.51 0.129
185 0.51 0.106
240 0.51 0.0801

ELECTRICAL CHARACTERISTICS

NOMINAL CROSSS

ECTIONAL AREA

mm²

REFERENCE METHOD A

(ENCLOSED IN

CONDUIT IN THERMALLY

INSULATING WALL ETC)

Amps

REFERENCE METHOD B

(ENCLOSED IN CONDUIT

IN WALL OR IN

TRUNKING ETC)
Amps

REFERENCE METHOD C

(CLIPPED DIRECT)
Amps

REFERENCE METHOD F

(IN FREE AIR OR ONA PERFORATED CABLE TRAY ETC HORIZONTAL OR VERTICAL ETC)

Amps

Touching

Spaced by

one diameter

2 Cables Single-Phase ACor DC or3 Cables Three-Phase AC flat

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

AC or DC

3 or 4Cables

Three-Phase

AC

2Cables

SinglePhase

AC or DCflat

3Cables

Three-Phase

ACflat

3 Cables

Three-Phase

ACtrefoil

Horizontal Vertical
1.5 14.5 13.5 17.5 15.5 20 18 - - - - -
2.5 20 18 24 21 27 25 - - - - -
4 26 24 32 28 37 33 - - - - -
6 34 31 41 36 47 43 - - - - -
10 46 42 57 50 65 59 - - - - -
16 61 56 76 68 87 79 - - - - -
25 80 73 101 89 114 104 131 114 110 146 130
35 99 89 125 110 141 129 162 143 137 181 162
50 119 108 151 134 182 167 196 174 167 219 192
70 151 136 192 171 234 214 251 225 216 281 254
95 182 164 232 207 284 261 304 275 264 341 311
120 210 188 269 239 330 303 352 321 308 396 362
150 240 216 300 262 381 349 406 372 356 456 419
185 273 245 341 296 436 400 463 427 409 521 480
240 321 286 400 346 515 472 546 507 485 615 569
CERTIFICATIONS

 

control cabinet panel wire supplier

control cabinet internal wire supplier

PACKAGING

 

motor starter wire supplier

Roll

control cabinet H05V-K supplier

Plastic Reel

motor starter wire manufacturer

Small Wooden Reel

APPLICATION

 

motor starter panel wire supplier
Industrial Control Panel
motor starter internal wire supplier
Renewable Energy Power Connection
motor starter H05V-K supplier

Switchboard Wiring

 

CASE

 

rectifier equipment wire supplier

Adelaide Airport Switchboard Upgrade

rectifier equipment wire manufacturer

Industrial Main Switchboard Power Distribution

what is H05V-K cable

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

what is H05V-K wire
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

what is H05V-K wire
 
what does H05V-K mean
 
H05V-K cable meaning
 
H05V-K cable specification
 
H05V-K wire specification
 
H05V-K cable datasheet
 
GLOBAL CERTIFICATIONS

 

H05V-K cable datasheet

CUSTOMER PHOTOS
 

H05V-K cable standard

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

H05V-K EN 50525-2-31
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

H05V-K IEC 60228 Class 5
H05V-K flame retardant standard
H05V-K voltage rating
H05V-K temperature rating
H05V-K conductor class
H05V-K insulation material
H05V-K cable construction
H05V-K wire structure
H05V-K cable sizes
H05V-K available sizes
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

H05V-K 0.5 0.75 1 mm2
FAQ

 

Can H05V-K be used inside a BMS cabinet?
H05V-K is often selected for this requirement, but the exact application still needs a drawing and code check. The relevant search term is H05V-K BMS cabinet wire. Yes, suitable protected power, relay and discrete control links inside a BMS panel can use H05V-K. Cell-sense harnesses and communication buses may require different specialised wire. For international orders, GERITEL WIRE can prepare technical and packing information needed for purchasing, inspection and shipment coordination.
Can H05V-K be used inside a PCS cabinet?
This is a common purchasing question because H05V-K is sold under several market descriptions. The relevant search term is H05V-K PCS control wire. It can be used for fixed internal control and auxiliary circuits in a power-conversion-system cabinet where the cable rating is sufficient. Main AC/DC power circuits need separately sized power conductors. GERITEL WIRE can confirm the requested size, colour, marking and packing details before production so the order matches the drawing.
Can H05V-K be used inside an EMS control panel?
In panel building, the practical answer depends on how the conductor is protected and terminated. The relevant search term is H05V-K EMS panel wire. Yes, internal controller, relay and auxiliary wiring in a protected EMS panel can be a suitable application. Network communication should use the specified data cable. For OEM projects, GERITEL WIRE can support technical data review, sample confirmation and practical reel or box packing.
Can H05V-K be used in containerized battery storage systems?
From a specification standpoint, H05V-K has a clear use boundary that should not be stretched by marketing claims. The relevant search term is H05V-K BESS control wire. It can be used inside protected control cabinets within a BESS container if temperature, enclosure and code requirements are satisfied. Container environmental conditions must be considered separately from the cable's indoor panel role. GERITEL WIRE can help compare the requested construction with the project specification before quotation, reducing avoidable model mismatches.

 

Hot Tags: ev charging station internal control wire – en 50525-2-31 flexible pvc solution, China ev charging station internal control wire – en 50525-2-31 flexible pvc solution manufacturers, suppliers, factory, HO5V-K

Send Inquiry