Industrial Data Center UPS Control Cabinet Wire Fine-Stranded Class 5 Copper

Industrial Data Center UPS Control Cabinet Wire Fine-Stranded Class 5 Copper
Details:
·Conductor: Class 5 flexible copper conductor
·Insulation: PVC (Polyvinyl Chloride)
·Voltage Rating Uo/U: H05V-K:300/500V ; H07V-K:450/750V
·Temperature Rating: Fixed: -30°C to +70℃ ; Flexed: -5°C to +70℃
·Standards: EN 50525-2-31, EN 60228 ; Flame Retardant according to IEC/EN 60332-1-2 ; UV Resistant
Send Inquiry
Download
Description
Technical Parameters
Certification

H05V-K cable colours

PRODUCT REAL SHOT

 

H05V-K wire colours
H05V-K bending radius
H05V-K conductor resistance

H05V-K outside diameter

A Practical H05V-K wire for UPS internal control wiring for Electrical Equipment Manufacturers
For data-center power-equipment OEMs and panel builders, H05V-K provides a 300/500V single-core PVC-insulated flexible conductor for protected UPS control cabinets, monitoring panels and equipment interconnections. Buyers often search the same need as UPS panel wire, data center control cabinet wire or flexible internal equipment wire. H05V-K can be positioned for appropriate internal control circuits, not as a data-center feeder or branch power cable. The product should be positioned as internal/protected wiring rather than continuous-flex, exposed feeder or unrelated power-cable service. GERITEL WIRE supports colour, marking, reel packing and export-document requirements for OEM orders.
PRODUCT SPECIFICATIONS

 

H05V-K cable weight

Applications

 

PVC panel wiring for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.

SPECIFICATIONS
Voltage Rating Uo/U

H05V-K:300/500V

H07V-K:450/750V

Temperature Rating

Fixed: -30°C to +70°C

Flexed: -5°C to +70°C

Minimum Bending Radius Fixed: 6 x overall diameter
Conductor Class 5 flexible copper conductor
Insulation PVC (Polyvinyl Chloride)
Insulation Colour Red,Black,Blue,Orange,Yellow,White,Green/Yellow,Violet,Pink,Grey,Brown
STANDARDS

EN 50525-2-31,EN 60228

Flame Retardant according to IEC/EN 60332-1-2

UV Resistant

DIMENSIONS

NOMINAL CROSS SECTIONAL AREA

mm²

NOMINAL OVERALL DIAMETER

mm²

NOMINAL WEIGHT

kg/km

H05V-K
0.5 2.20 9.1
0.75 2.40 11.7
1 2.55 14.4
H07V-K
1.5 3.00 20.1
2.5 3.65 31.5
4 4.20 46.2
6 4.80 65.1
10 6.25 109.4
16 7.40 165.2
25 9.40 253.4
35 10.40 345.5
50 12.55 492.4
70 14.10 669.3
95 17.20 910.4
120 17.70 1129.4
150 19.60 1401.0
185 23.00 1741.0
240 26.40 2267.5

CONDUCTORS

NOMINAL CROSS

SECTIONAL AREA

mm²

MAXIMUM DIAMETER

OF WIRES IN CONDUCTOR

mm

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Plain Wires
0.5 0.21 39
0.75 0.21 26
1 0.21 19.5
1.5 0.26 13.3
2.5 0.26 7.98
4 0.31 4.95
6 0.31 3.3
10 0.41 1.91
16 0.41 1.21
25 0.41 0.78
35 0.41 0.554
50 0.41 0.386
70 0.51 0.272
95 0.51 0.206
120 0.51 0.161
150 0.51 0.129
185 0.51 0.106
240 0.51 0.0801

ELECTRICAL CHARACTERISTICS

NOMINAL CROSSS

ECTIONAL AREA

mm²

REFERENCE METHOD A

(ENCLOSED IN

CONDUIT IN THERMALLY

INSULATING WALL ETC)

Amps

REFERENCE METHOD B

(ENCLOSED IN CONDUIT

IN WALL OR IN

TRUNKING ETC)
Amps

REFERENCE METHOD C

(CLIPPED DIRECT)
Amps

REFERENCE METHOD F

(IN FREE AIR OR ONA PERFORATED CABLE TRAY ETC HORIZONTAL OR VERTICAL ETC)

Amps

Touching

Spaced by

one diameter

2 Cables Single-Phase ACor DC or3 Cables Three-Phase AC flat

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

AC or DC

3 or 4Cables

Three-Phase

AC

2Cables

SinglePhase

AC or DCflat

3Cables

Three-Phase

ACflat

3 Cables

Three-Phase

ACtrefoil

Horizontal Vertical
1.5 14.5 13.5 17.5 15.5 20 18 - - - - -
2.5 20 18 24 21 27 25 - - - - -
4 26 24 32 28 37 33 - - - - -
6 34 31 41 36 47 43 - - - - -
10 46 42 57 50 65 59 - - - - -
16 61 56 76 68 87 79 - - - - -
25 80 73 101 89 114 104 131 114 110 146 130
35 99 89 125 110 141 129 162 143 137 181 162
50 119 108 151 134 182 167 196 174 167 219 192
70 151 136 192 171 234 214 251 225 216 281 254
95 182 164 232 207 284 261 304 275 264 341 311
120 210 188 269 239 330 303 352 321 308 396 362
150 240 216 300 262 381 349 406 372 356 456 419
185 273 245 341 296 436 400 463 427 409 521 480
240 321 286 400 346 515 472 546 507 485 615 569
CERTIFICATIONS

 

H05V-K reel length

H05V-K per metre

PACKAGING

 

H05V-K fixed installation

Roll

H05V-K protected installation

Plastic Reel

H05V-K internal wiring applications

Small Wooden Reel

APPLICATION

 

H05V-K switchgear applications
Industrial Control Panel
H05V-K hook up wire applications
Renewable Energy Power Connection
H05V-K equipment wire applications

Switchboard Wiring

 

CASE

 

H05V-K for signal circuits

Adelaide Airport Switchboard Upgrade

H05V-K for monitoring circuits

Industrial Main Switchboard Power Distribution

can H05V-K be used in control panels

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

can H05V-K be used in switchgear
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

can H05V-K be used for equipment wiring
 
can H05V-K be used in lighting fixtures
 
can H05V-K be used in charging stations
 
can H05V-K be used in modular houses
 
can H05V-K be used in energy storage systems
 
can H05V-K be used in data centers
 
GLOBAL CERTIFICATIONS

 

can H05V-K be used in solar inverters

CUSTOMER PHOTOS
 

is H05V-K suitable for fixed wiring

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

is H05V-K flexible
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

is H05V-K flame retardant
is H05V-K halogen free
is H05V-K UV resistant
is H05V-K suitable for outdoor use
is H05V-K suitable for continuous flexing
H05V-K vs H07V-K difference
is H05V-K a hook up wire
is H05V-K a panel wire
H05V-K vs H07V-K comparison
H05V-K vs H07V-K which cable to use
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

HH05V-K vs H07V-K specification comparison
FAQ

 

Can H05V-K be used for fire-suppression control inside ESS cabinets?
For OEM wiring, the safest approach is to match the cable type to the actual circuit rather than choose by colour or flexibility alone. The relevant search term is H05V-K ESS control panel wire. It may be used for appropriate internal control connections, but any circuit requiring fire survival or special life-safety certification must use the specified fire-performance cable. Do not rely on simple flame retardancy for circuit integrity. If the project has a specific terminal, cabinet or wiring standard, GERITEL WIRE can review the key parameters with the buyer before order release.
Can H05V-K be used for contactor coil wiring in battery racks?
The product can be a good fit, provided the voltage, cross-section and protected-installation conditions are correct. The relevant search term is H05V-K contactor control wire. Yes, protected fixed coil and relay-control wiring can be a suitable duty if conductor size and insulation coordination are correct. Battery rack power paths remain a separate specification. GERITEL WIRE supports OEM identification, colour planning and export documentation according to the final agreed product scope.
Can H05V-K be used for cabinet fans and auxiliary loads in ESS?
Buyers should treat this as a selection question rather than a yes/no marketing claim. The relevant search term is H05V-K auxiliary control wire. It may be used for suitable internal low-power auxiliary connections after current and temperature checks. Fan supply current and protection must be included in the sizing calculation. For repeat panel production, GERITEL WIRE can discuss consistent colour coding, printing and packaging to simplify workshop handling.
What should an ESS buyer confirm before ordering H05V-K?
Yes, when the installation conditions match the H05V-K design. The relevant search term is H05V-K ESS panel wire. Confirm circuit voltage, current, conductor size, colour schedule, enclosure temperature, terminal type and required compliance documents. Keep control-wire purchasing separate from battery/high-current cable purchasing. GERITEL WIRE can provide the applicable datasheet and available compliance documents for the exact ordered construction for buyer review.

 

Hot Tags: industrial data center ups control cabinet wire fine-stranded class 5 copper, China industrial data center ups control cabinet wire fine-stranded class 5 copper manufacturers, suppliers, factory, HO5V-K

Send Inquiry