4 Mm² H07V-K Wire For HVAC And Pump Control Panel Applications

4 Mm² H07V-K Wire For HVAC And Pump Control Panel Applications
Details:
·Conductor: Class 5 flexible copper conductor
·Insulation: PVC (Polyvinyl Chloride)
·Voltage Rating Uo/U: H05V-K:300/500V ; H07V-K:450/750V
·Temperature Rating: Fixed: -30°C to +70℃ ; Flexed: -5°C to +70℃
·Standards: EN 50525-2-31, EN 60228 ; Flame Retardant according to IEC/EN 60332-1-2 ; UV Resistant
Send Inquiry
Download
Description
Technical Parameters
Certification

H07V-K 4mm2 cable

PRODUCT REAL SHOT

 

H07V-K 4 mm2 wire
4mm2 H07V-K cable
4 sq mm H07V-K wire

H07V-K 4mm cable

Flexible 4 mm² Building Services Cable for Protected Control Equipment
HVAC and building-service panels frequently combine controllers, contactors, relays and pumps in compact electrical assemblies. H07V-K can be used as 4 mm² HVAC control panel wire for suitable protected power, control and auxiliary circuits inside these cabinets. The flexible conductor also supports pump control cabinet cable installations where technicians need clean routing between terminals and switching devices. For integrated building systems, it may serve as building automation power wire when the circuit does not require a screened communication cable. GERITEL WIRE can support colour-coded supply, OEM printing and export packing, while the engineering team should confirm circuit duty, temperature and local installation rules.
PRODUCT SPECIFICATIONS

 

2491X H07V-K 4mm2 cable

Applications

 

PVC panel wiring for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.

SPECIFICATIONS
Voltage Rating Uo/U

H05V-K:300/500V

H07V-K:450/750V

Temperature Rating

Fixed: -30°C to +70°C

Flexed: -5°C to +70°C

Minimum Bending Radius Fixed: 6 x overall diameter
Conductor Class 5 flexible copper conductor
Insulation PVC (Polyvinyl Chloride)
Insulation Colour Red,Black,Blue,Orange,Yellow,White,Green/Yellow,Violet,Pink,Grey,Brown
STANDARDS

EN 50525-2-31,EN 60228

Flame Retardant according to IEC/EN 60332-1-2

UV Resistant

DIMENSIONS

NOMINAL CROSS SECTIONAL AREA

mm²

NOMINAL OVERALL DIAMETER

mm²

NOMINAL WEIGHT

kg/km

H05V-K
0.5 2.20 9.1
0.75 2.40 11.7
1 2.55 14.4
H07V-K
1.5 3.00 20.1
2.5 3.65 31.5
4 4.20 46.2
6 4.80 65.1
10 6.25 109.4
16 7.40 165.2
25 9.40 253.4
35 10.40 345.5
50 12.55 492.4
70 14.10 669.3
95 17.20 910.4
120 17.70 1129.4
150 19.60 1401.0
185 23.00 1741.0
240 26.40 2267.5

CONDUCTORS

NOMINAL CROSS

SECTIONAL AREA

mm²

MAXIMUM DIAMETER

OF WIRES IN CONDUCTOR

mm

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Plain Wires
0.5 0.21 39
0.75 0.21 26
1 0.21 19.5
1.5 0.26 13.3
2.5 0.26 7.98
4 0.31 4.95
6 0.31 3.3
10 0.41 1.91
16 0.41 1.21
25 0.41 0.78
35 0.41 0.554
50 0.41 0.386
70 0.51 0.272
95 0.51 0.206
120 0.51 0.161
150 0.51 0.129
185 0.51 0.106
240 0.51 0.0801

ELECTRICAL CHARACTERISTICS

NOMINAL CROSSS

ECTIONAL AREA

mm²

REFERENCE METHOD A

(ENCLOSED IN

CONDUIT IN THERMALLY

INSULATING WALL ETC)

Amps

REFERENCE METHOD B

(ENCLOSED IN CONDUIT

IN WALL OR IN

TRUNKING ETC)
Amps

REFERENCE METHOD C

(CLIPPED DIRECT)
Amps

REFERENCE METHOD F

(IN FREE AIR OR ONA PERFORATED CABLE TRAY ETC HORIZONTAL OR VERTICAL ETC)

Amps

Touching

Spaced by

one diameter

2 Cables Single-Phase ACor DC or3 Cables Three-Phase AC flat

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

AC or DC

3 or 4Cables

Three-Phase

AC

2Cables

SinglePhase

AC or DCflat

3Cables

Three-Phase

ACflat

3 Cables

Three-Phase

ACtrefoil

Horizontal Vertical
1.5 14.5 13.5 17.5 15.5 20 18 - - - - -
2.5 20 18 24 21 27 25 - - - - -
4 26 24 32 28 37 33 - - - - -
6 34 31 41 36 47 43 - - - - -
10 46 42 57 50 65 59 - - - - -
16 61 56 76 68 87 79 - - - - -
25 80 73 101 89 114 104 131 114 110 146 130
35 99 89 125 110 141 129 162 143 137 181 162
50 119 108 151 134 182 167 196 174 167 219 192
70 151 136 192 171 234 214 251 225 216 281 254
95 182 164 232 207 284 261 304 275 264 341 311
120 210 188 269 239 330 303 352 321 308 396 362
150 240 216 300 262 381 349 406 372 356 456 419
185 273 245 341 296 436 400 463 427 409 521 480
240 321 286 400 346 515 472 546 507 485 615 569
CERTIFICATIONS

 

2491X 4mm2 cable

H07VK 4mm wire

PACKAGING

 

07V-K 4mm cable

Roll

4mm2 flexible panel wire

Plastic Reel

4mm2 panel wire

Small Wooden Reel

APPLICATION

 

4mm2 single core flexible cable
Industrial Control Panel
4mm2 PVC single core wire
Renewable Energy Power Connection
4mm2 Class 5 flexible wire

Switchboard Wiring

 

CASE

 

4mm2 flexible copper wire

Adelaide Airport Switchboard Upgrade

4mm2 control cabinet wire

Industrial Main Switchboard Power Distribution

4mm2 equipment wire

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

4mm 450/750V flexible cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

H07V-K 4mm2 datasheet
 
H07V-K 4mm2 current rating
 
H07V-K 4mm2 amp rating
 
H07V-K 4mm2 current carrying capacity
 
H07V-K 4mm2 conductor resistance
 
H07V-K 4mm2 cable diameter
 
GLOBAL CERTIFICATIONS

 

H07V-K 4mm2 cable weight

CUSTOMER PHOTOS
 

EN 50525-2-31 4mm2 cable

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

IEC 60228 Class 5 4mm2 wire
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

H07V-K 4mm2 technical specification
4mm2 PLC cabinet wire
4mm2 DIN rail wiring cable
4mm2 machine control wire
4mm2 HVAC control panel wire
4mm2 relay panel wire
4mm2 instrumentation panel wire
4mm2 terminal block wire
4mm2 BMS control panel wire
4mm2 solar inverter internal wire
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

4mm2 EV charger internal wire
FAQ

 

Is H07V-K suitable for automated panel production?
The consistent single-core construction makes H07V-K useful as automatic panel wiring cable for cut, strip, mark and crimp workflows. Machine settings and first-article inspection should be established before high-volume production. GERITEL WIRE can support OEM identification and private-label packaging when the marking and compliance requirements are confirmed before production.
What if my machine has strong vibration?
A fine-stranded conductor can perform well as vibration resistant panel wire in many fixed cabinet applications, but termination quality is critical. Use compatible ferrules or terminals and provide strain relief where the wiring could move. For engineering buyers, GERITEL WIRE can compare the requested installation with the cable construction and flag when another cable family would be technically safer.
Can H07V-K be used for lighting circuits?
H07V-K is used as lighting equipment wire and in suitable protected lighting installations where local rules allow flexible single cores. For exposed, sheathed or fire-critical circuits, another cable construction may be required. GERITEL WIRE can align production packing with panel-shop handling, automated wire processing or distributor stocking requirements for repeat orders.
Can H07V-K be used inside luminaires?
H07V-K can support luminaire internal wiring when the temperature and appliance requirements are suitable. High-temperature luminaires may need heat-resistant wire rather than standard PVC H07V-K. If the project has several circuits or destination markets, GERITEL WIRE can help separate H07V-K applications from circuits that need LSZH, screened, high-temperature or continuous-flex cable.

 

Hot Tags: 4 mm² h07v-k wire for hvac and pump control panel applications, China 4 mm² h07v-k wire for hvac and pump control panel applications manufacturers, suppliers, factory, HO7V-K

Send Inquiry