H07V-K Single Core Flexible Cable For Electrical Panel Building

H07V-K Single Core Flexible Cable For Electrical Panel Building
Details:
·Conductor: Class 5 flexible copper conductor
·Insulation: PVC (Polyvinyl Chloride)
·Voltage Rating Uo/U: H05V-K:300/500V ; H07V-K:450/750V
·Temperature Rating: Fixed: -30°C to +70℃ ; Flexed: -5°C to +70℃
·Standards: EN 50525-2-31, EN 60228 ; Flame Retardant according to IEC/EN 60332-1-2 ; UV Resistant
Send Inquiry
Download
Description
Technical Parameters
Certification

control wire

PRODUCT REAL SHOT

 

control wiring cable
switchgear wire
switchgear cable

switchboard wire

Flexible Single Core Wire for Fixed and Protected Installation
H07V-K is widely used where panel builders need one flexible conductor per circuit rather than a multi-core cable. As electrical panel wire, its fine copper strands help technicians bend and dress conductors around DIN-rail devices, terminals and wiring channels without the stiffness of solid building wire. The fine stranded copper wire construction also supports repetitive cut-strip-crimp processing in panel workshops. GERITEL WIRE can coordinate standard colours, printing and packing for OEM projects. When specified as a protected installation cable, H07V-K should be selected within its voltage, temperature and installation limits and should not be treated as a continuous-flex drag-chain cable.
PRODUCT SPECIFICATIONS

 

distribution board wire

Applications

 

PVC panel wiring for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.

SPECIFICATIONS
Voltage Rating Uo/U

H05V-K:300/500V

H07V-K:450/750V

Temperature Rating

Fixed: -30°C to +70°C

Flexed: -5°C to +70°C

Minimum Bending Radius Fixed: 6 x overall diameter
Conductor Class 5 flexible copper conductor
Insulation PVC (Polyvinyl Chloride)
Insulation Colour Red,Black,Blue,Orange,Yellow,White,Green/Yellow,Violet,Pink,Grey,Brown
STANDARDS

EN 50525-2-31,EN 60228

Flame Retardant according to IEC/EN 60332-1-2

UV Resistant

DIMENSIONS

NOMINAL CROSS SECTIONAL AREA

mm²

NOMINAL OVERALL DIAMETER

mm²

NOMINAL WEIGHT

kg/km

H05V-K
0.5 2.20 9.1
0.75 2.40 11.7
1 2.55 14.4
H07V-K
1.5 3.00 20.1
2.5 3.65 31.5
4 4.20 46.2
6 4.80 65.1
10 6.25 109.4
16 7.40 165.2
25 9.40 253.4
35 10.40 345.5
50 12.55 492.4
70 14.10 669.3
95 17.20 910.4
120 17.70 1129.4
150 19.60 1401.0
185 23.00 1741.0
240 26.40 2267.5

CONDUCTORS

NOMINAL CROSS

SECTIONAL AREA

mm²

MAXIMUM DIAMETER

OF WIRES IN CONDUCTOR

mm

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Plain Wires
0.5 0.21 39
0.75 0.21 26
1 0.21 19.5
1.5 0.26 13.3
2.5 0.26 7.98
4 0.31 4.95
6 0.31 3.3
10 0.41 1.91
16 0.41 1.21
25 0.41 0.78
35 0.41 0.554
50 0.41 0.386
70 0.51 0.272
95 0.51 0.206
120 0.51 0.161
150 0.51 0.129
185 0.51 0.106
240 0.51 0.0801

ELECTRICAL CHARACTERISTICS

NOMINAL CROSSS

ECTIONAL AREA

mm²

REFERENCE METHOD A

(ENCLOSED IN

CONDUIT IN THERMALLY

INSULATING WALL ETC)

Amps

REFERENCE METHOD B

(ENCLOSED IN CONDUIT

IN WALL OR IN

TRUNKING ETC)
Amps

REFERENCE METHOD C

(CLIPPED DIRECT)
Amps

REFERENCE METHOD F

(IN FREE AIR OR ONA PERFORATED CABLE TRAY ETC HORIZONTAL OR VERTICAL ETC)

Amps

Touching

Spaced by

one diameter

2 Cables Single-Phase ACor DC or3 Cables Three-Phase AC flat

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

AC or DC

3 or 4Cables

Three-Phase

AC

2Cables

SinglePhase

AC or DCflat

3Cables

Three-Phase

ACflat

3 Cables

Three-Phase

ACtrefoil

Horizontal Vertical
1.5 14.5 13.5 17.5 15.5 20 18 - - - - -
2.5 20 18 24 21 27 25 - - - - -
4 26 24 32 28 37 33 - - - - -
6 34 31 41 36 47 43 - - - - -
10 46 42 57 50 65 59 - - - - -
16 61 56 76 68 87 79 - - - - -
25 80 73 101 89 114 104 131 114 110 146 130
35 99 89 125 110 141 129 162 143 137 181 162
50 119 108 151 134 182 167 196 174 167 219 192
70 151 136 192 171 234 214 251 225 216 281 254
95 182 164 232 207 284 261 304 275 264 341 311
120 210 188 269 239 330 303 352 321 308 396 362
150 240 216 300 262 381 349 406 372 356 456 419
185 273 245 341 296 436 400 463 427 409 521 480
240 321 286 400 346 515 472 546 507 485 615 569
CERTIFICATIONS

 

switchboard cable

installation wire

PACKAGING

 

installation cable

Roll

fixed wiring cable

Plastic Reel

fixed wiring wire

Small Wooden Reel

APPLICATION

 

building wire
Industrial Control Panel
flexible building wire
Renewable Energy Power Connection
electrical installation wire

Switchboard Wiring

 

CASE

 

electrical wiring cable

Adelaide Airport Switchboard Upgrade

electrical wire

Industrial Main Switchboard Power Distribution

flexible electrical wire

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

power and control cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

flexible power and control cable
 
control cabinet single core
 
panel building wire
 
panel building cable
 
panel hookup wire
 
switchboard panel wire
 
GLOBAL CERTIFICATIONS

 

instrumentation panel wire

CUSTOMER PHOTOS
 

relay panel wire

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

machine wiring cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

machine wire
machine control wire
apparatus wire
electrical apparatus wire
device wiring cable
equipment hookup wire
wiring cable
flexible wiring cable
single conductor wire
flexible single conductor wire
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

PVC insulated single conductor wire
FAQ

 

Does H07V-K have an outer sheath?
No. It is normally a PVC insulated single core wire without a separate outer sheath. That is why it is commonly routed inside equipment, cabinets, conduit or other protected systems rather than exposed where a sheathed cable is required. GERITEL WIRE applies incoming-material and finished-product quality controls and can discuss available inspection records or project documentation for the ordered construction.
What is the rated voltage of H07V-K?
H07V-K is commonly specified as 450/750V flexible wire. The voltage designation is only one part of selection; current, installation method, terminal rating, temperature and local rules also determine whether it fits the circuit. Where certification matters, GERITEL WIRE can check the exact certificate scope for the ordered product instead of relying on a general brand-level approval claim.
Why do some suppliers call H07V-K panel wire?
The term flexible panel wire is common because H07V-K is widely used for point-to-point wiring inside electrical panels, switchboards and equipment. It describes the market application rather than a different conductor construction. GERITEL WIRE can support OEM identification and private-label packaging when the marking and compliance requirements are confirmed before production.
Can H07V-K be described as a power and control cable?
Some European catalogues group H07V-K under power and control cable families because it serves internal power, control and auxiliary circuits. It remains a single-core conductor, so it should not be confused with a screened or multi-core control cable. For engineering buyers, GERITEL WIRE can compare the requested installation with the cable construction and flag when another cable family would be technically safer.

 

Hot Tags: h07v-k single core flexible cable for electrical panel building, China h07v-k single core flexible cable for electrical panel building manufacturers, suppliers, factory, HO7V-K

Send Inquiry