H07V-K Hook Up Wire For Internal Electrical Equipment Connections

H07V-K Hook Up Wire For Internal Electrical Equipment Connections
Details:
·Conductor: Class 5 flexible copper conductor
·Insulation: PVC (Polyvinyl Chloride)
·Voltage Rating Uo/U: H05V-K:300/500V ; H07V-K:450/750V
·Temperature Rating: Fixed: -30°C to +70℃ ; Flexed: -5°C to +70℃
·Standards: EN 50525-2-31, EN 60228 ; Flame Retardant according to IEC/EN 60332-1-2 ; UV Resistant
Send Inquiry
Download
Description
Technical Parameters
Certification

panel wiring wire

PRODUCT REAL SHOT

 

cabinet wiring wire
industrial panel wire
industrial control wire

H07V-K cable

Flexible Hook Up Wire for Devices, Terminals and Control Circuits
For OEM equipment and electrical assemblies, H07V-K can serve as equipment hookup wire for short protected connections between switches, relays, power supplies, terminals and control devices. The flexible copper construction makes each single conductor wire easier to form inside compact equipment than rigid alternatives, while PVC insulation provides a familiar surface for marking, stripping and termination. GERITEL WIRE can support colour-coded supply, private marking and production-friendly packaging for manufacturers. In internal equipment wiring, circuit voltage, current, ambient temperature and terminal compatibility should be reviewed so the selected cable matches the real equipment design rather than a generic hook-up-wire assumption.
PRODUCT SPECIFICATIONS

 

H07V-K wire

Applications

 

PVC panel wiring for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.

SPECIFICATIONS
Voltage Rating Uo/U

H05V-K:300/500V

H07V-K:450/750V

Temperature Rating

Fixed: -30°C to +70°C

Flexed: -5°C to +70°C

Minimum Bending Radius Fixed: 6 x overall diameter
Conductor Class 5 flexible copper conductor
Insulation PVC (Polyvinyl Chloride)
Insulation Colour Red,Black,Blue,Orange,Yellow,White,Green/Yellow,Violet,Pink,Grey,Brown
STANDARDS

EN 50525-2-31,EN 60228

Flame Retardant according to IEC/EN 60332-1-2

UV Resistant

DIMENSIONS

NOMINAL CROSS SECTIONAL AREA

mm²

NOMINAL OVERALL DIAMETER

mm²

NOMINAL WEIGHT

kg/km

H05V-K
0.5 2.20 9.1
0.75 2.40 11.7
1 2.55 14.4
H07V-K
1.5 3.00 20.1
2.5 3.65 31.5
4 4.20 46.2
6 4.80 65.1
10 6.25 109.4
16 7.40 165.2
25 9.40 253.4
35 10.40 345.5
50 12.55 492.4
70 14.10 669.3
95 17.20 910.4
120 17.70 1129.4
150 19.60 1401.0
185 23.00 1741.0
240 26.40 2267.5

CONDUCTORS

NOMINAL CROSS

SECTIONAL AREA

mm²

MAXIMUM DIAMETER

OF WIRES IN CONDUCTOR

mm

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Plain Wires
0.5 0.21 39
0.75 0.21 26
1 0.21 19.5
1.5 0.26 13.3
2.5 0.26 7.98
4 0.31 4.95
6 0.31 3.3
10 0.41 1.91
16 0.41 1.21
25 0.41 0.78
35 0.41 0.554
50 0.41 0.386
70 0.51 0.272
95 0.51 0.206
120 0.51 0.161
150 0.51 0.129
185 0.51 0.106
240 0.51 0.0801

ELECTRICAL CHARACTERISTICS

NOMINAL CROSSS

ECTIONAL AREA

mm²

REFERENCE METHOD A

(ENCLOSED IN

CONDUIT IN THERMALLY

INSULATING WALL ETC)

Amps

REFERENCE METHOD B

(ENCLOSED IN CONDUIT

IN WALL OR IN

TRUNKING ETC)
Amps

REFERENCE METHOD C

(CLIPPED DIRECT)
Amps

REFERENCE METHOD F

(IN FREE AIR OR ONA PERFORATED CABLE TRAY ETC HORIZONTAL OR VERTICAL ETC)

Amps

Touching

Spaced by

one diameter

2 Cables Single-Phase ACor DC or3 Cables Three-Phase AC flat

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

AC or DC

3 or 4Cables

Three-Phase

AC

2Cables

SinglePhase

AC or DCflat

3Cables

Three-Phase

ACflat

3 Cables

Three-Phase

ACtrefoil

Horizontal Vertical
1.5 14.5 13.5 17.5 15.5 20 18 - - - - -
2.5 20 18 24 21 27 25 - - - - -
4 26 24 32 28 37 33 - - - - -
6 34 31 41 36 47 43 - - - - -
10 46 42 57 50 65 59 - - - - -
16 61 56 76 68 87 79 - - - - -
25 80 73 101 89 114 104 131 114 110 146 130
35 99 89 125 110 141 129 162 143 137 181 162
50 119 108 151 134 182 167 196 174 167 219 192
70 151 136 192 171 234 214 251 225 216 281 254
95 182 164 232 207 284 261 304 275 264 341 311
120 210 188 269 239 330 303 352 321 308 396 362
150 240 216 300 262 381 349 406 372 356 456 419
185 273 245 341 296 436 400 463 427 409 521 480
240 321 286 400 346 515 472 546 507 485 615 569
CERTIFICATIONS

 

H07V-K flexible wire

H07V-K flexible cable

PACKAGING

 

H07V-K panel wire

Roll

H07V-K panel cable

Plastic Reel

H07V-K single core cable

Small Wooden Reel

APPLICATION

 

H07V-K single core wire
Industrial Control Panel
H07V-K PVC wire
Renewable Energy Power Connection
H07V-K PVC cable

Switchboard Wiring

 

CASE

 

H07V-K flexible PVC wire

Adelaide Airport Switchboard Upgrade

H07V-K flexible PVC cable

Industrial Main Switchboard Power Distribution

H07V-K control wire

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

H07V-K control cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

H07V-K equipment wire
 
H07V-K equipment cable
 
H07V-K hook up wire
 
H07V-K control cabinet wire
 
H07V-K control cabinet cable
 
H07V-K switchgear wire
 
GLOBAL CERTIFICATIONS

 

H07V-K switchboard wire

CUSTOMER PHOTOS
 

H07V-K building wire

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

H07V-K installation wire
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

H07V-K internal wiring cable
H07V-K electrical wire
H07V-K power and control cable
H07V-K flexible copper wire
H07V-K Class 5 wire
H07V-K Class 5 cable
H07V-K harmonised cable
H07V-K HAR cable
H07V-K HAR wire
H07V-K 450/750V cable
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

H07V-K 450/750V wire
FAQ

 

Can H07V-K be used as hook-up wire?
Yes, distributors may list H07V-K hook up wire for protected internal equipment connections. The buyer should still check voltage, temperature and approval requirements because the generic term hook-up wire covers many different constructions. GERITEL WIRE can align production packing with panel-shop handling, automated wire processing or distributor stocking requirements for repeat orders.
Is 2491X the same as H07V-K?
2491X cable is a common UK-market reference for flexible PVC single-core panel and equipment wiring, and H07V-K may be supplied within that family depending on the exact standard and rating. Always compare the datasheet instead of assuming every 2491X listing is identical. If the project has several circuits or destination markets, GERITEL WIRE can help separate H07V-K applications from circuits that need LSZH, screened, high-temperature or continuous-flex cable.
What conductor class is used in H07V-K?
H07V-K normally uses an IEC 60228 Class 5 conductor made from many fine copper strands. This construction improves installation flexibility and makes routing through crowded cabinet layouts easier than with solid conductors. GERITEL WIRE can provide technical data review and practical export packing so the purchasing team has clearer information before approving mass production.
Is the conductor bare copper or tinned copper?
Standard H07V-K is commonly made with fine stranded copper wire using bare annealed copper. Tinned copper should not be assumed unless it is specifically stated in the manufacturer specification or project requirement. For long-term programs, GERITEL WIRE can coordinate consistent colour identification, labels and order documentation to reduce avoidable receiving and assembly errors.

 

Hot Tags: h07v-k hook up wire for internal electrical equipment connections, China h07v-k hook up wire for internal electrical equipment connections manufacturers, suppliers, factory, HO7V-K