600V 16Awg SOOW Cable

600V 16Awg SOOW Cable
Details:
Resistance to oils, chemicals, and UV radiation
Suitable for use in harsh environments
More than 20 years of production experience
Quick online quote & free samples available
Send Inquiry
Download
Description
Technical Parameters
Certification
H07RN-F cable

 

16awg SOOW Cable
 

600V 16 AWG SOOW cable is composed of pure copper strands, the cable provides reliable electrical performance with a rated capacity of up to 600 volts. The internal conductors are insulated with color-coded, flexible CPE (Chlorinated Polyethylene) insulation, offering ease of identification and enhanced flexibility. The cable is protected by a durable, abrasion-resistant CPE outer jacket, designed to withstand harsh conditions and physical wear.

● Voltage Rating: 450/750v
● Conductor: Flexible, Bare Copper Class 5
● Insulation And Sheath: Rubber
● Operating Temperature Range: -25 -55℃
● Short-Circuit Maximum Core Temperature: 200℃

 

Application

 

 

600V 16 awg SOOW cable is ideal for both indoor and outdoor use, including in industrial settings, construction sites, and areas where exposure to environmental factors is a concern. Its robust design makes it suitable for use in a variety of demanding applications, providing reliable performance and longevity.

HO7RN-F application

 

Certification

 

SOOW cable certification

 

Our products have achieved various prestigious international certifications, including UL, TUV, EU CPR, CE, ROHS, and others.

 

Package

 

HO7RN-F  package

 

Factory

 

HO7RN-F suppliers

 

1. 20 years experience in cable manufacturing, 20+ technicians, 15 sets of cable extruder lines, export to 89 countries servicing more than 180+ countries and regions, 20 sets of cable test equipment, strictly quality control max cross area 12000mm2.
2. Customized cable support and quick delivery.
3. Our products have passed CB, CE, VDE, ROHS, TUV, UL, SAA, CCC, and other certifications, and the quality is reliable.

 

Case

 

HO7RN-F Cable Manufacturer

 

Partner

 

greater wire Partner

 

FAQ

 

Q: Is SOOW wire waterproof?

A: SOOW wire is designed to be highly resistant to moisture but is not classified as fully waterproof. The insulation and outer jacket of SOOW wire are made to withstand exposure to water and moisture. This makes it suitable for use in environments where the wire may encounter damp conditions or occasional splashes. While SOOW wire is resistant to moisture, it is not intended for continuous submersion or direct contact with water. For applications requiring complete waterproofing, a cable specifically rated for underwater use or submersion is recommended.

Q: Does SOOW cable need conduit?

A: SOOW cable does not strictly require conduit for protection in all applications, but using conduit can provide additional benefits, especially in certain situations.

Q: Can SOOW cable be buried?

A: SOOW cable is not typically designed or rated for direct burial applications.

 

 

Hot Tags: 600v 16awg soow cable, China 600v 16awg soow cable manufacturers, suppliers, factory, hook up wire, SAA Australia Flat Twin Active TPS Cable, ac cable, multicore rubber cable, HO5V-K, xhhw rw 90 rhw wire

SJOO

 

Size
Noof
conductor
Conductor
strand
Nominal
insulation
thickness
Nominal
jacket
thickness
Nominal
overall
diameter
Weight
Ampacity
at30°C
in air
Inches
mm
Inches
mm
Inches
mm
lbs/1000ft
A
18 2 16/30 0.030 0.76 0.060 1.52 0.34 8.6 63 10
18 3 16/30 0.030 0.76 0.060 1.52 0.36 9.1 74 10
18 4 16/30 0.030 0.76 0.060 1.52 0.39 9.8 87 7
18 5 16/30 0.030 0.76 0.080 2.03 0.46 11.7 123 5.6
18 6 16/30 0.030 0.76 0.080 2.03 0.48 12.3 131 5.6
18 7 16/30 0.030 0.76 0.080 2.03 0.48 12.3 134 5.6
18 8 16/30 0.030 0.76 0.080 2.03 0.52 13.1 151 4.9
18 10 16/30 0.030 0.76 0.080 2.03 0.59 15.0 180 4.9
18 12 16/30 0.030 0.76 0.080 2.03 0.61 15.4 202 3.5
18 14 16/30 0.030 0.76 0.095 2.41 0.66 16.9 246 3.5
18 16 16/30 0.030 0.76 0.095 2.41 0.69 17.6 274 3.5
18 18 16/30 0.030 0.76 0.095 2.41 0.73 18.5 303 3.5
18 20 16/30 0.030 0.76 0.095 2.41 0.76 19.3 333 3.5
18 22 16/30 0.030 0.76 0.095 2.41 0.83 21.2 357 3.2
18 24 16/30 0.030 0.76 0.095 2.41 0.83 21.2 376 3.2
18 26 16/30 0.030 0.76 0.095 2.41 0.85 21.7 401 3.2
18 27 16/30 0.030 0.76 0.095 2.41 0.85 21.9 409 3.2
18 30 16/30 0.030 0.76 0.110 2.79 0.91 23.0 470 3.2
18 36 16/30 0.030 0.76 0.110 2.79 0.97 24.7 551 2.8
18 39 16/30 0.030 0.76 0.110 2.79 1.04 26.3 604 2.8
18 44 16/30 0.030 0.76 0.110 2.79 1.08 27.4 647 2.5
18 52 16/30 0.030 0.76 0.110 2.79 1.12 28.5 735 2.5
18 60 16/30 0.030 0.76 0.125 3.18 1.22 30.9 870 2.5
16 2 26/30 0.030 0.76 0.060 1.52 0.37 9.3 76 13
16 3 26/30 0.030 0.76 0.060 1.52 0.39 10.1 90 13
16 4 26/30 0.030 0.76 0.060 1.52 0.42 10.6 107 10
16 5 26/30 0.030 0.76 0.080 2.03 0.49 12.5 149 8
16 6 26/30 0.030 0.76 0.080 2.03 0.53 13.4 165 8
16 7 26/30 0.030 0.76 0.080 2.03 0.53 13.4 170 8
16 8 26/30 0.030 0.76 0.080 2.03 0.56 14.3 193 7
16 9 26/30 0.030 0.76 0.095 2.41 0.65 16.5 238 7
16 10 26/30 0.030 0.76 0.095 2.41 0.68 17.2 251 7
16 12 26/30 0.030 0.76 0.095 2.41 0.70 17.7 282 5
16 14 26/30 0.030 0.76 0.095 2.41 0.73 18.5 316 5
16 16 26/30 0.030 0.76 0.095 2.41 0.76 19.4 354 5
16 18 26/30 0.030 0.76 0.095 2.41 0.80 20.3 393 5
16 20 26/30 0.030 0.76 0.095 2.41 0.84 21.2 434 5
16 22 26/30 0.030 0.76 0.095 2.41 0.92 23.4 464 4.5
16 24 26/30 0.030 0.76 0.110 2.79 0.95 24.1 520 4.5
16 27 26/30 0.030 0.76 0.110 2.79 0.97 24.6 566 4.5
16 30 26/30 0.030 0.76 0.110 2.79 1.00 25.4 615 4.5
16 36 26/30 0.030 0.76 0.110 2.79 1.07 27.3 724 4
16 37 26/30 0.030 0.76 0.110 2.79 1.07 27.3 730 4
16 39 26/30 0.030 0.76 0.110 2.79 1.15 29.1 795 4
16 40 26/30 0.030 0.76 0.125 3.18 1.18 29.9 843 4
16 44 26/30 0.030 0.76 0.125 3.18 1.23 31.1 891 3.5
16 52 26/30 0.030 0.76 0.125 3.18 1.28 32.4 1016 3.5
16 60 26/30 0.030 0.76 0.125 3.18 1.35 34.2 1154 3.5
14 2 41/30 0.045 1.14 0.080 2.03 0.50 12.6 137 18
14 3 41/30 0.045 1.14 0.080 2.03 0.52 13.3 161 18
14 4 41/30 0.045 1.14 0.080 2.03 0.57 14.4 192 15
14 5 41/30 0.045 1.14 0.095 2.41 0.64 16.4 251 12
14 6 41/30 0.045 1.14 0.095 2.41 0.69 17.6 277 12
14 7 41/30 0.045 1.14 0.095 2.41 0.69 17.6 285 12
14 8 41/30 0.045 1.14 0.095 2.41 0.74 18.9 324 10.5
14 9 41/30 0.045 1.14 0.095 2.41 0.86 21.9 367 10.5
14 10 41/30 0.045 1.14 0.095 2.41 0.86 21.9 388 10.5
14 12 41/30 0.045 1.14 0.095 2.41 0.89 22.5 441 7.5
14 14 41/30 0.045 1.14 0.095 2.41 0.93 23.6 498 7.5
14 16 41/30 0.045 1.14 0.095 2.41 0.98 24.8 563 7.5
14 18 41/30 0.045 1.14 0.110 2.79 1.06 26.9 660 7.5
14 20 41/30 0.045 1.14 0.110 2.79 1.11 28.1 730 7.5
14 24 41/30 0.045 1.14 0.110 2.79 1.22 31.1 828 6.8
14 30 41/30 0.045 1.14 0.125 3.18 1.32 33.6 1027 6.8
14 36 41/30 0.045 1.14 0.125 3.18 1.42 36.2 1215 6.0
14 37 41/30 0.045 1.14 0.125 3.18 1.42 36.2 1224 6.0
14 44 41/30 0.045 1.14 0.125 3.18 1.59 40.4 1437 5.3
14 52 41/30 0.045 1.14 0.125 3.18 1.66 42.2 1648 5.3
14 60 41/30 0.045 1.14 0.140 3.56 1.79 45.5 1939 5.3
12 2 65/30 0.045 1.14 0.095 2.41 0.57 14.4 184 25
12 3 65/30 0.045 1.14 0.095 2.41 0.59 15.2 217 25
12 4 65/30 0.045 1.14 0.095 2.41 0.64 16.5 261 20
12 5 65/30 0.045 1.14 0.095 2.41 0.70 17.8 319 16
12 6 65/30 0.045 1.14 0.095 2.41 0.74 18.8 344 16
12 7 65/30 0.045 1.14 0.095 2.41 0.74 18.8 358 16
12 8 65/30 0.045 1.14 0.095 2.41 0.80 20.2 408 14
12 9 65/30 0.045 1.14 0.095 2.41 0.92 23.5 461 14
12 10 65/30 0.045 1.14 0.110 2.79 0.95 24.2 519 14
12 12 65/30 0.045 1.14 0.110 2.79 0.98 24.9 591 10
12 14 65/30 0.045 1.14 0.110 2.79 1.03 26.1 668 10
12 16 65/30 0.045 1.14 0.110 2.79 1.08 27.5 755 10
12 18 65/30 0.045 1.14 0.125 3.18 1.17 29.6 878 10
12 20 65/30 0.045 1.14 0.125 3.18 1.22 31.0 971 10
12 24 65/30 0.045 1.14 0.125 3.18 1.35 34.3 1106 9
12 26 65/30 0.045 1.14 0.125 3.18 1.38 35.0 1180 9
12 30 65/30 0.045 1.14 0.125 3.18 1.43 36.3 1327 9
12 36 65/30 0.045 1.14 0.125 3.18 1.53 39.0 1573 8
12 37 65/30 0.045 1.14 0.125 3.18 1.53 39.0 1588 8
12 44 65/30 0.045 1.14 0.125 3.18 1.72 43.6 1868 7
12 60 65/30 0.045 1.14 0.140 3.56 1.90 48.3 2467 7
10 2 103/30 0.045 1.14 0.095 2.41 0.62 15.6 230 30
10 3 103/30 0.045 1.14 0.095 2.41 0.65 16.5 281 30
10 4 103/30 0.045 1.14 0.095 2.41 0.70 17.8 336 25
10 5 103/30 0.045 1.14 0.095 2.41 0.76 19.3 409 20
10 6 103/30 0.045 1.14 0.095 2.41 0.82 20.7 452 20
10 7 103/30 0.045 1.14 0.095 2.41 0.82 20.7 474 20
10 8 103/30 0.045 1.14 0.095 2.41 0.88 22.3 541 17.5
10 10 103/30 0.045 1.14 0.110 2.79 1.05 26.8 686 17.5
10 12 103/30 0.045 1.14 0.110 2.79 1.09 27.6 788 12.5
10 16 103/30 0.045 1.14 0.125 3.18 1.23 31.2 1053 12.5
10 20 103/30 0.045 1.14 0.125 3.18 1.35 34.4 1304 12.5
10 24 103/30 0.045 1.14 0.125 3.18 1.50 38.2 1494 11.3
10 26 103/30 0.045 1.14 0.125 3.18 1.54 39.0 1598 11.3
10 30 103/30 0.045 1.14 0.125 3.18 1.59 40.4 1803 11.3
10 34 103/30 0.045 1.14 0.140 3.56 1.74 44.3 2105 10
10 36 103/30 0.045 1.14 0.140 3.56 1.74 44.3 2201 10
10 40 103/30 0.045 1.14 0.140 3.56 1.87 47.4 2464 10
8 2 67/0.0156 0.060 1.52 0.110 2.79 0.78 19.8 367 40
8 3 67/0.0156 0.060 1.52 0.110 2.79 0.83 21.1 452 40
8 4 67/0.0156 0.060 1.52 0.125 3.18 0.93 23.5 577 35
8 5 67/0.0156 0.060 1.52 0.125 3.18 1.00 25.4 683 28
8 6 67/0.0156 0.060 1.52 0.140 3.56 1.106 28.1 804 28
6 2 184/0.0117 0.060 1.52 0.125 3.18 0.92 23.4 525 55
6 3 184/0.0117 0.060 1.52 0.125 3.18 0.97 24.6 641 55
6 4 184/0.0117 0.060 1.52 0.140 3.56 1.05 26.7 785 45
6 5 184/0.0117 0.060 1.52 0.140 3.56 1.18 30.0 983 36
4 2 165/0.0156 0.060 1.52 0.140 3.56 1.06 26.9 728 70
4 3 165/0.0156 0.060 1.52 0.140 3.56 1.13 28.7 913 70
4 4 165/0.0156 0.060 1.52 0.155 3.94 1.25 31.8 1156 60
4 5 165/0.0156 0.060 1.52 0.155 3.94 1.31 33.2 1318 48
2 2 262/0.0156 0.060 1.52 0.155 3.94 1.21 30.7 1000 95
2 3 262/0.0156 0.060 1.52 0.155 3.94 1.30 33.1 1287 95
2 4 262/0.0156 0.060 1.52 0.170 4.32 1.45 36.8 1644 80
2 5 262/0.0156 0.060 1.52 0.170 4.32 1.53 38.8 1900 64

NOTE 1. Ampacity values shown are for current carrying conductors. A grounding conductor, or one which carries only the

unbalanced current from other conductors, is not counted in determining current carrying capacity

NOTE 2. Correction factor for ambient temperature of 40°C is 0.91

UL62 soow cable

Send Inquiry