0.6/1kV Power Cable Kenya For Contractors And Electrical Wholesalers

0.6/1kV Power Cable Kenya For Contractors And Electrical Wholesalers
Details:
·Conductor:RE: Class 1 solid copper conductor RM: Class 2 stranded circular or circular compacted SM: Class 2 stranded sectoral shaped
·Insulation: XLPE (Cross-Linked Polyethylene)
·Bedding: PVC (Polyvinyl Chloride)
·Sheath: PVC (Polyvinyl Chloride)
·Voltage Rating Uo/U: 0.6/1kV
·Temperature Rating:During installation -5℃ to +50℃ Fixed Installation: -20℃ to +90℃
·Standards:IEC 60502-1, Gen to VDE 0276-603, IEC/EN 60228 Flame retardant according to IEC/EN 60332-1-2
Send Inquiry
Download
Description
Technical Parameters
Certification

fournisseur câble U-1000 R2V 0,6/1 kV Mali

PRODUCT REAL SHOT

 

fabricant câble U-1000 R2V 0,6/1 kV Mali
grossiste câble U-1000 R2V 0,6/1 kV Mali
câble U-1000 R2V 0,6/1 kV fiche technique Mali

câble U-1000 R2V 0,6/1 kV catalogue Mali

Kenya copper XLPE PVC cable for commercial buildings and industrial plants
This Kenya page targets real sourcing terms used by Nairobi distributors, MEP contractors and project buyers looking for 0.6/1 kV fixed power cable. Designed for permanent low-voltage circuits, the cable pairs Class 1 or Class 2 copper with XLPE insulation and a durable PVC jacket. Buyers using the phrase unarmoured XLPE cable supplier Nairobi can compare this exact construction without mixing it with aluminium, armoured, LSZH or Class 5 flexible cable. Applications include shopping centres, factories, apartments, cold stores, pumping stations and protected service routes within infrastructure projects. GERITEL WIRE provides cable schedules, dimensional details, export packing and shipping paperwork for approved orders.
PRODUCT SPECIFICATIONS

 

câble U-1000 R2V 0,6/1 kV IEC 60502-1 Mali

Applications

 

These power and fixed wiring cables are used for electricity supply in low voltage installation systems. They are well adapted to underground use in industrial applications with an additional mechanical protection. These cables can be fixed on cable trays, within conduits or fixed to walls.

SPECIFICATIONS
Voltage Rating Uo/U 0.6/1kV
Temperature Rating

During installation -5°C to +50°C

Fixed Installation: -20°C to +90°C

Minimum Bending Radius Fixed: 12 x overall diameter
Conductor

RE: Class 1 solid copper conductor

RM: Class 2 stranded circular or circular compacted

SM: Class 2 stranded sectoral shaped

Insulation XLPE (Cross-Linked Polyethylene)
Bedding PVC (Polyvinyl Chloride)
Sheath PVC (Polyvinyl Chloride)
Core Identification

3 core: Green/Yellow,Blue,Brown4 core

4 core: Green/Yellow,Brown,Black,Grey

5 core: Green/Yellow,Blue,Brown,Black,Grey

7 cores and above: Black cores and,White numbers

Sheath Colour Black
STANDARDS IEC 60502-1, Gen to VDE 0276-603, IEC/EN 60228 Flame retardant according to IEC/EN 60332-1-2

DIMENSIONS

NO. OF
CORES

NOMINALCROSS

SECTIONALAREA

mm²

CONDUCTOR

TYPE

NOMINAL

THICKNESS

OF INSULATION

mm

NOMINAL

THICKNESS

OF SHEATH

mm²

NOMINAL OVERALL

DIAMETER

mm

NOMINAL WEIGHT

kg/km

1 16 RM 0.7 1.8 9.8 216
1 25 RM 0.9 1.8 11.5 318
1 35 RM 0.9 1.8 12.6 415
1 50 RM 1 1.8 14.1 543
1 70 RM 1.1 1.8 15.6 746
1 95 RM 1.1 1.8 17.6 1000
1 120 RM 1.2 1.8 19.2 1239
1 150 RM 1.4 1.8 21.2 1515
1 185 RM 1.6 1.8 23.1 1872
1 240 RM 1.7 1.8 25.8 2403
1 300 RM 1.8 1.8 2.78 2974
1 400 RM 2 1.9 31.1 3834
1 500 RM 2.2 2 34.9 4892
1 630 RM 2.8 2.8 46.6 6544
2 1.5 RE 0.7 1.8 10.1 145
2 2.5 RE 0.7 1.8 10.9 179
2 4 RE 0.7 1.8 11.8 226
2 6 RE 0.7 1.8 12.8 284
2 6 RM 0.7 1.8 13.1 295
2 10 RM 0.7 1.8 15 416
2 16 RM 0.7 1.8 17 581
2 25 RM 0.9 1.8 20.4 859
2 35 RM 0.9 1.8 22.5 1109
3 1.5 RE 0.7 1.8 10.5 162
3 2.5 RE 0.7 1.8 11.4 205
3 4 RE 0.7 1.8 12.4 265
3 6 RE 0.7 1.8 13.4 338
3 10 RM 0.7 1.8 15.8 505
3 16 RM 0.7 1.8 18 719
3 25 RM 0.9 1.8 21.6 1072
3 35 RM 0.9 1.8 23.9 1403
3 50 SM 1 1.9 23.8 1581
3 16/10 SM 0.7 1.8 19.8 875.5
3 25/16 SM 0.9/0.7 1.8 22.4 1223
3 35/16 SM 0.9/0.7 1.8 24.3 1557
3 50/25 SM 1/0.9 1.9 26.9 1863
3 70/35 SM 1.1/0.9 2 30 2594
3 95/50 SM 1.1/1 2.2 33.8 3505
3 120/70 SM 1.2/1.1 2.3 37 4440
3 150/70 SM 1.4/1.1 2.4 41.6 5333
3 185/95 SM 1.6/1.1 2.6 45.8 6701
3 240/120 SM 1.7/1.2 2.8 51.6 8674
3 300/150 SM 1.8/1.4 3 67.2 10624
4 1.5 RE 0.7 1.8 11.3 188
4 2.5 RE 0.7 1.8 12.2 240
4 4 RE 0.7 1.8 13.3 314
4 6 RE 0.7 1.8 14.5 408
4 10 RE 0.7 1.8 17.1 615
4 16 RE 0.7 1.8 19.6 885
4 25 RE 0.9 1.8 23.7 1330
4 35 RE 0.9 1.8 26.2 1758
4 50 SM 1 2 27.1 2082
4 70 SM 1.1 2.1 31.4 2937
4 95 SM 1.1 2.2 35 3955
4 120 SM 1.2 2.4 39.3 4979
4 150 SM 1.4 2.6 43.6 6129
4 185 SM 1.6 2.7 48 7591
4 240 SM 1.7 2.9 53.9 9875
4 300 SM 1.8 2.6 68.9 15124
5 1.5 RE 0.7 1.8 12.1 218
5 2.5 RE 0.7 1.8 13.1 281
5 4 RE 0.7 1.8 14.3 372
5 6 RE 0.7 1.8 15.6 486
5 10 RM 0.7 1.8 18.6 740
5 16 RM 0.7 1.8 21.3 1071
5 25 RM 0.9 1.8 25.9 1619
5 35 RM 0.9 1.8 28.8 2138
5 50 RM 1 2.1 29.4 2578
5 70 RM 1.1 2.2 33.7 3616
5 95 RM 1.1 2.4 38.6 4933
5 120 RM 1.2 2.5 42.6 6153
5 150 RM 1.4 2.7 47.7 7587
5 185 RM 1.6 2.9 52.8 9454
5 240 RM 1.7 3.1 58.7 12242
7 1.5 RE 0.7 1.8 12.9 260
7 2.5 RE 0.7 1.8 14 342
7 4 RE 0.7 1.8 15.4 461
10 1.5 RE 0.7 1.8 15.6 357
10 2.5 RE 0.7 1.8 17.2 475
10 4 RE 0.7 1.8 19 646
12 1.5 RE 0.7 1.8 16.1 394
12 2.5 RE 0.7 1.8 17.6 528
14 1.5 RE 0.7 1.8 16.8 436
14 2.5 RE 0.7 1.8 18.5 592
16 4 RM 0.7 1.8 23 971
19 1.5 RE 0.7 1.8 18.4 543
19 2.5 RE 0.7 1.8 20.3 746
24 1.5 RE 0.7 1.8 21.2 675
24 2.5 RE 0.7 1.8 23.4 931
30 1.5 RE 0.7 1.8 22.3 788
30 2.5 RM 0.7 1.8 26.3 7764
40 1.5 RE 0.7 1.8 24.6 995
40 2.5 RE 0.7 1.9 27.5 1416

CONDUCTORS

Class 1 Solid Conductors for Single-Core and Multi-Core Cables

NOMINAL CROSSS

ECTIONAL AREA

mm²

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Circular, Annealed Copper Conductors
Plain
0.5 36
0.75 24.5
1 18.1
1.5 12.1
2.5 7.41
4 4.61
6 3.08

 

Class 2 Stranded Conductors for Single-Core and Multi-Core Cables

NOMINAL CROSS

SECTIONAL AREA

mm²

MINIMUM NO. OF WIRES IN THE CONDUCTOR

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Circular Circular Compacted Annealed Copper Conductors
Cu Cu Plain Wires
4 7 6 4.51
6 7 6 3.08
10 7 6 1.83
16 7 6 1.15
25 7 6 0.727
35 7 6 0.524
50 19 6 0.387
70 19 12 0.268
95 19 15 0.193
120 37 18 0.153
150 37 18 0.124
185 37 30 0.0991
240 37 34 0.0754
300 61 34 0.0601
400 61 53 0.0470
500 61 53 0.0366

ELECTRICAL CHARACTERISTICS

Current Carrying Capacity at 30°C

NOMINAL CROSS

SECTIONAL AREA

mm²

SINGLE CORE

2-40 CORE

Amps

In Ground In Air In Ground In Air
Flat Trefoil Flat Trefoil
1.5 - - - - 31 24
2.5 - - - - 40 32
4 82 54 57 44 52 42
6 102 67 72 56 64 53
10 136 89 99 77 86 74
16 176 115 131 102 112 98
25 229 148 177 138 145 133
35 275 177 217 170 174 162
50 326 209 265 207 206 197
70 400 256 336 263 254 250
95 480 307 415 325 305 308
120 548 349 485 380 348 359
150 616 393 557 437 392 412
185 698 445 646 507 444 475
240 815 517 774 604 517 564
300 927 663 901 697 585 649
400 1064 749 1060 811 - -
500 1227 843 1252 940 - -

DE-RATING FACTORS

For Ground Temperatures other than 20°C

AIR TEMPERATURE 10°C 15°C 20°C 25°C 30°C 35°C 40°C 45°C 50°C
DE-RATING FACTOR 1.07 1.04 1.00 0.96 0.93 0.89 0.85 0.80 0.76

 

For Air Temperatures other than 30°C

AIR TEMPERATURE 20°C 25°C 30°C 35°C 40°C 45°C 50°C 55°C 60°C
DE-RATING FACTOR 1.08 1.04 1.00 0.96 0.91 0.87 0.82 0.76 0.71
CERTIFICATIONS

 

câble U-1000 R2V 0,6/1 kV courant admissible Mali

PACKAGING

 

câble cuivre XLPE PVC Mali

Roll

prix câble cuivre XLPE PVC Mali

Small Wooden Reel

fournisseur câble cuivre XLPE PVC Mali

Steel Wooden Reel

APPLICATION

 

fabricant câble cuivre XLPE PVC Mali
High-Rise Commercial Building Main Power Distribution
grossiste câble cuivre XLPE PVC Mali
Industrial Plant Low-Voltage Power Distribution
câble cuivre XLPE PVC fiche technique Mali

Municipal Water Treatment and Pumping Station Power Supply

 

CASE

 

câble cuivre XLPE PVC catalogue Mali

Babanusa–Adila Power Transmission Project

câble cuivre XLPE PVC IEC 60502-1 Mali

Italy Electricity Test Project

câble cuivre XLPE PVC courant admissible Mali

Oyu Tolgoi Copper Mine Project

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

câble électrique non armé 1 kV Mali
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

prix câble électrique non armé 1 kV Mali
 
fournisseur câble électrique non armé 1 kV Mali
 
fabricant câble électrique non armé 1 kV Mali
 
grossiste câble électrique non armé 1 kV Mali
 
câble électrique non armé 1 kV fiche technique Mali
 
câble électrique non armé 1 kV catalogue Mali
 
GLOBAL CERTIFICATIONS

 

câble électrique non armé 1 kV IEC 60502-1 Mali

CUSTOMER PHOTOS
 

câble électrique non armé 1 kV courant admissible Mali

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

câble U-1000 R2V 0,6/1 kV Burkina Faso
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

prix câble U-1000 R2V 0,6/1 kV Burkina Faso
fournisseur câble U-1000 R2V 0,6/1 kV Burkina Faso
fabricant câble U-1000 R2V 0,6/1 kV Burkina Faso
grossiste câble U-1000 R2V 0,6/1 kV Burkina Faso
câble U-1000 R2V 0,6/1 kV fiche technique Burkina Faso
câble U-1000 R2V 0,6/1 kV catalogue Burkina Faso
câble U-1000 R2V 0,6/1 kV IEC 60502-1 Burkina Faso
câble U-1000 R2V 0,6/1 kV courant admissible Burkina Faso
câble cuivre XLPE PVC Burkina Faso
câble cuivre XLPE PVC Burkina Faso
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

fournisseur câble cuivre XLPE PVC Burkina Faso
FAQ

 

What cable data is needed for a generator output feeder?
Provide generator rating, voltage, power factor, short-circuit contribution, neutral arrangement, harmonic loads, route length and installation method. Vibration may require flexible tails at the machine interface. GERITEL WIRE treats generator output copper power cable as a project-specific requirement, not a label-only substitution. GERITEL WIRE can review destination requirements and separate the standard PVC design from LSZH or armoured alternatives. Include certificate scope and destination-market requirements in the technical approval process.
Can this cable connect a transformer secondary to the LV board?
For transformer secondary XLPE cable: Yes, when voltage, current, fault duty, parallel arrangement, bending space and protection are correctly engineered. Large single-core installations also need magnetic and phase-layout review. GERITEL WIRE supports repeat orders through approved specifications, production records and consistent identification. A complete BOQ helps prevent price comparison between materially different cable constructions.
Can an IEC 60502-1 1kV cable be used on a DC system?
Certain DC applications may be possible when the standard, voltage limits and manufacturer declaration support them. Do not automatically substitute it for photovoltaic DC cable or battery interconnect cable. A reliable IEC 60502-1 cable for DC distribution decision therefore needs an approved construction and installation basis. GERITEL WIRE can supply bilingual technical and shipping documents when these are agreed before manufacture. Installation and termination details should be checked by the responsible project engineer.
Can Cu/XLPE/PVC cable be installed on cable trays?
Yes, cable trays and ladders are common fixed routes when support, spacing, grouping, fire requirements and mechanical exposure are properly addressed. Tray fill and derating must be calculated. For buyers searching Cu XLPE PVC cable tray installation, GERITEL WIRE can review the cable schedule and issue a construction-specific datasheet before quotation. Send the destination, standard, sizes, core arrangement, quantities and installation route for a precise offer.

 

Hot Tags: 0.6/1kv power cable kenya for contractors and electrical wholesalers, China 0.6/1kv power cable kenya for contractors and electrical wholesalers manufacturers, suppliers, factory, XLPE Copper Cable, xlpe unarmoured cable

Send Inquiry