600V Construction Site Power Cord Royal Cord BPS Certified

600V Construction Site Power Cord Royal Cord BPS Certified
Details:
·Conductors: Bare, soft annealed copper per ASTM B-3; Bunched-stranded per ASTM B 172 & ASTM B 174 standard. (PNS 163)
·Insulation: Lead Free Flame Retardant PVC per UL62 Standard
·Jacket: Lead Free Flame Retardant PVC per UL62 Standard
·Color: Black and White for 2 conductors;Black, white, and red for 3 conductors;Black, white, red, & green for 4 conductors
·Voltage: 600V
Send Inquiry
Download
Description
Technical Parameters
Certification

flexible cord for data center construction tools

PRODUCT REAL SHOT

 

portable power cord for data center construction tools
flexible power cable for data center construction tools
service cord for data center construction tools

temporary power cord for data center construction tools

Flexible Cord for Construction Tools, Site Equipment and Temporary Lighting
This GERITEL WIRE 600V Royal Cord uses a BPS-certified product positioning with flexible stranded copper conductors, individually insulated cores and one shared PVC jacket. A key long-tail phrase is portable power cord for construction tools, matching searches from builders, subcontractors, site managers, rental fleets and project buyers for construction tools, temporary work areas, portable site equipment and construction lighting. The multi-core structure gives manufacturers and installers a cleaner equipment lead than routing separate loose wires. The page is designed to capture a distinct product or application search intent within a broader Royal Cord SEO traffic matrix. Use suitable connectors, overcurrent protection, grounding and jobsite temporary-power practices.
PRODUCT SPECIFICATIONS

 

Royal Cord for data center maintenance equipment

Applications

 

Royal Cord are primarily used for light,medium, and heavy duty power supply toappliances, office equipment in the PhilippineElectri Code. Other applications include wiring forwashing machines and various other largeapplicances, heavy duty tools, motors, andtemporary electrical power and lighting installationfor construction site. The conductor suitable forapplications at temperature not exceeding 75 degrees C and voltage not exceeding 600 Volts.

SPECIFICATIONS
Conductors

Bare, soft annealed copper per ASTM B-3

Bunched-stranded per ASTM B 172 & ASTM B 174 standard. (PNS 163)

Insulation Lead Free Flame Retardant PVC per UL62 Standard
Jacket Lead Free Flame Retardant PVC per UL62 Standard
Color

Black and White for 2 conductors

Black, white, and red for 3 conductors

Black, white, red, & green for 4 conductors

Voltage 600V
Size/Nom. Area of Conductor No. & Diameter of Conductor Approx. Over-all Diameter of Conductor Max. Conductor Resistance Ampacity
(A)
Test Voltage Standard Length
mm² No./mm mm

Ohm/km

A B Volts m
0.75 30/0.18 1.1 23.52 7 10 2000 75
1.25 50/0.18 1.5 14.11 10 13 2000 75
2.0 37/0.26 1.8 9.14 15 18 3000 75
3.5 65/0.26 2.4 5.20 20 25 3000 75
5.5 104/0.26 3.0 3.25 25 30 3000 75
8.0 7/22/0.26 4.2 2.24 35 40 4000 75
14 7/38/0.26 5.5 1.30 45 55 4000 75
22 7/60/0.26 6.8 0.820 60 70 4000 75
30 7/81/0.26 8.0 0.620 80 95 4000 75

Size/Nom.

Areas of

Conductor

2 conductors 3 conductors 4 conductors

Approx. 

over-all

diameter

Approx.
weight

Approx.

over-all

diameter

Approx.
weight

Approx.

over-all

diameter

Approx.
weight
mm² mm Kg/km mm Kg/km mm Kg/km
0.75 8.40 75 8.80 92 9.5 111
1.25 9.20 93 9.68 117 10.5 143
2.0 12.40 165 13.05 205 14.14 250
3.5 14.40 235 15.14 295 16.39 361
5.5 15.60 293 16.44 377 17.84 467
8.0 20.20 511 21.32 632 24.00 823
14 23.60 744 24.92 926 27.92 1200
22 27.00 1030 28.52 1296 31.70 1663
30 30.00 1292 31.71 1648 35.35 2130
CERTIFICATIONS

 

portable cord for data center maintenance equipment

PACKAGING

 

flexible cord for data center maintenance equipment

Household Appliances

portable power cord for data center maintenance equipment

Office Commercial Equipment

flexible power cable for data center maintenance equipment

Portable Equipment Temporary Power

APPLICATION

 

flexible power cable for data center maintenance equipment
Cebu Ports Authority Cebu Port Pier 1 Smart WiFi Project
temporary power cord for data center maintenance equipment
Purefoods-Hormel Meat Processing Plant
stranded copper conductor Royal Cord

Taiheiyo Cement Philippines Plant

 

CASE

 

stranded copper conductor portable cord

Roll

stranded copper conductor flexible cord

Small Wooden Reel

Royal Cord with stranded copper conductor

Large Wooden Reel

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

portable cord with stranded copper conductor
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

soft annealed copper conductor Royal Cord
 
soft annealed copper conductor portable cord
 
soft annealed copper conductor flexible cord
 
Royal Cord with soft annealed copper conductor
 
portable cord with soft annealed copper conductor
 
bunched stranded copper conductor Royal Cord
 
GLOBAL CERTIFICATIONS

 

bunched stranded copper conductor portable cord

CUSTOMER PHOTOS
 

bunched stranded copper conductor flexible cord

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

Royal Cord with bunched stranded copper conductor
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

portable cord with bunched stranded copper conductor
rope lay flexible conductor Royal Cord
rope lay flexible conductor portable cord
rope lay flexible conductor flexible cord
Royal Cord with rope lay flexible conductor
portable cord with rope lay flexible conductor
high flexibility conductor Royal Cord
high flexibility conductor portable cord
high flexibility conductor flexible cord
Royal Cord with high flexibility conductor
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

portable cord with high flexibility conductor
FAQ

 

Should conductor colors match the equipment wiring diagram?
Yes. With color coded flexible cord, conductor colors are helpful during assembly, but installers should always follow the equipment diagram and local wiring rules rather than assuming the function from color alone.
Can GERITEL WIRE prepare Royal Cord for assembly?
Yes. GERITEL WIRE can support Royal Cord cable assembly supplier discussions for OEM production, including length, marking and packaging requirements. The exact assembly preparation should be confirmed before mass production.
Is Royal Cord resistant to normal abrasion?
abrasion resistant Royal Cord is designed to tolerate normal handling better than bare insulated wires because the outer jacket protects the cores. Severe dragging, crushing or contact with sharp metal can still damage the cable and should be avoided.
Can Royal Cord be used in humid environments?
moisture resistant flexible cord may be used in humid environments only if the selected product specification and installation method allow it. Moisture exposure, connectors and equipment ingress protection all need to be considered together.

 

Hot Tags: 600v construction site power cord royal cord bps certified, China 600v construction site power cord royal cord bps certified manufacturers, suppliers, factory

Send Inquiry