PVC MV 105 15kV Cable Single Core

PVC MV 105 15kV Cable Single Core
Details:
Approvals:
• UL Listed as Type MV-105 per UL 1072
• Meets flame testing requirements of UL 1685 and IEEE 1202/CSA FT4
• Marked sunlight-resistant
• Sizes 1/0 AWG and larger are marked for CT use
• Suitable for direct burial when installed with an appropriately sized ground wire in close proximity in accordance with the National Electrical Code
• RoHS Compliant
• High Speed low friction technology for easy cable pulling
Send Inquiry
Download
Description
Technical Parameters
Certification
MV 105 Cable

 

PVC MV 105 15kV Cable Single Core
 
 
  • Conductor: One compact bare stranded copper conductor,

  • Conductor shield: extruded semi-conducting conductor shield,

  • Insulation: lead free EPR insulation,

  • Insulation shield: extruded semi-conducting insulation shield, 5 mil bare copper shield tape with 25% minimum overlap

  • Jacket: overall low friction PVC jacket

  • Temperature Rating: 105˚C

  • Conductor Size Range: 2 AWG to 1000 kcmil

 

Application
application scenarios

PVC 15 kV UL Type MV 105 cable is designed for demanding medium voltage applications where durability, flexibility, and ease of installation are essential. With a compact bare stranded copper conductor and a robust overall low-friction PVC jacket, this cable delivers excellent mechanical protection and simplified pulling through conduit or trays. The 15 kV rating at 133% insulation level provides enhanced dielectric strength, making it ideal for long cable runs or installations with higher electrical stress.

MV 105 cable for commercial building

Commercial buildings

In high-rise buildings, MV wire run vertically through riser shafts to feed floor-by-floor electrical panels with power

MV 105 cable for factory

Factory

medium voltage cable power production lines that require stable voltage for high-speed, high-torque equipment.

MV 105 cables  for Railway

Railway

15kV cables supply stable power from traction substations to railway systems across urban and intercity routes

MV 105 cable for Power Stations

Power stations

MV wires are used to power air compressors, water treatment units, and lighting systems in power plants.

 

Certification

 

 

MV cable's UL certification (certificate number: E549302) not only recognizes product performance but also establishes a comprehensive traceability system for every production process. From conductor copper purity testing and insulation material formulation to cable production, sheath extrusion, and finished product inspection, every step is fully documented. Through UL's traceability system, cables are clearly documented with production batch numbers and test reports from the receipt of raw materials to final shipment. If any issues are discovered during use, the engineering department can quickly trace them back to the specific production date, process batch, and even the source of the raw materials.

UL certificated MV cable

 

Package
MV 105 Cables Packaging
MV 105 Cable Packaging

MV105 cables are usually packaged using export-grade wooden drums, suitable for long-distance transportation by land, sea, or air. Each reel is protected with plastic film or tarpaulin to shield it from moisture and UV exposure. Steel reinforcements may be added to the reel edges for added durability. Every drum includes barcode labels and handling instructions for safety and accuracy.

 

Factory
Dongguan Greater Wire & Cable Co.,Ltd.

Greater Wire, founded in 1995, is a trusted MV 105 cable manufacturer with over 30 years of production expertise. Backed by cutting-edge manufacturing equipment and a strict quality control system, we ensure each cable meets international standards. Our experienced technical team is dedicated to delivering high-performance wire & cable solutions that provide circuit integrity under any conditions. Whether for infrastructure, commercial, or industrial projects, Greater Wire offers dependable and customized wires and cables tailored to meet the safety and efficiency needs of global clients.

Professional team

From pre-sales consultation to after-sales support, we always provide customers with a full range of services.

7x24 hours online

Whether it is technical consultation, product quotation, order progress or after-sales support, our service team is on call 24/7 to quickly provide customers with professional answers and timely assistance.

fire rated cable manufacturer

50,000M²

Factory Area

30+Years

Production Experience

50+Servings

Product Certifications

24/7Hours

Customer Service

Our Services
 
 

Our team is dedicated to delivering high-quality service from inquiry to after-sales support.

 

Professional team

Our engineering team offers technical consulting, cable selection guidance, and customized design services for complex projects.

 
 

High quality product

We understand regional certification requirements and provide cables compliant with local standards such as UL, CE, TUV, SAA, and more.

 
 

Customized services

Our services include OEM/ODM production, labeling, packaging customization, and other support.

 
 

Worry-free after-sales

All orders are backed by our international after-sales policy, including free technical consultation, claim assistance, and replacement arrangements for quality defects.

 

 

 

Case
Success Case

Serving clients across North and Latin America, Greater Wire Manufacturer delivers electrical cables engineered for long-term reliability. We've supplied successful projects in aviation terminals, healthcare facilities, educational campuses, hotels, and factories, always providing solutions that meet strict safety and operational standards.

  • El Salvador Airport
    Salva
    El Salvador Airport
  • Guatemala Solar Power Project
    Guatemala
    Guatemala Solar Power Project
  • Marriott Hotels USA
    THE USA
    Marriott Hotels USA
  • Panama Metro Line 3
    Panama 
    Panama Metro Line 3

 

FAQ

 

Q: Are your MV cables UL listed or recognized? 

A: Yes, our medium voltage wires are UL listed and SAA certified.
Greater Wire Manufacturing offers MV wires that comply with UL 1072 standards for the US and Canada and are SAA certified for the Oceania market. Our products undergo rigorous testing to meet local electrical codes and industry-specific requirements, making them suitable for a variety of critical applications.

Q: What is the difference between MV90 and MV105 cables? 

A: The main difference between MV90 and MV105 lies in their maximum operating temperature ratings and insulation types, which affect where and how they can be safely installed.
MV90 is rated for 90°C continuous operating temperature.
MV105 is rated for 105°C continuous operating temperature.

Q: Is the cable environmentally friendly and safe?

A: Yes, Greater Wire's medium voltage wires are both environmentally friendly and safe, designed to meet stringent international standards for performance, safety, and sustainability.

Q:What after-sales service and technical support can you provide? 

A: At Greater Wire Manufacturer, we provide comprehensive after-sales service and technical support to ensure our customers have complete confidence with our products.
24/7 Customer Support: Our sales and service teams are available around the clock to assist with inquiries, order updates, and logistics tracking.
All products come with a quality guarantee. We support warranty claims, including test reports and compliance certificates.

 

 

 

Hot Tags: pvc mv 105 15kv cable single core, China pvc mv 105 15kv cable single core manufacturers, suppliers, factory

MV105 Cables

 

 

Conductor Size (Stranding) Nominal Insulation (Mils) Minimum O.D.Over Insulation (Inches) Maximum O.D.Over Insulation (Inches) Jacke Tthickness (Mils) Approx.Cable O.D. (Inches) Approx.Net Weight (LBS/1000 FT)
2 (7W) 220 0.71 0.8 80 0.99 658
1/0 (19W) 220 0.78 0.87 80 1.06 825
2/0 (19W) 220 0.82 0.91 80 1.1 938
4/0 (19W) 220 0.92 1.01 80 1.21 1261
250(37W) 220 0.97 1.06 80 1.25 1407
350(37W) 220 1.07 1.16 80 1.35 1783
500(37W) 220 1.19 1.28 80 1.47 2331
750(61W) 220 1.37 1.46 80 1.65 3234
1000(61W) 220 1.52 1.61 110 1.86 4219

 

UL1072-E549302
UL 1072
UL1072-E549302
UL 1072

 

 

Send Inquiry