MV105 Cable

MV105 Cable
Details:
Compliance
• Conductor resistance AS/NZS 1125
• Insulation resistance AS/NZS 1429.1
• Voltage test AS/NZS 1429.1
Standard and References
• AS/NZS 1429.1
• AS/NZS 1125
• AS/NZS 3808
Send Inquiry
Download
Description
Technical Parameters
Certification
3 Core Copper MV Wire

 

MV105 Cable
 
  • Conductor: Class B compressed stranded bare copper per ASTM B3 and ASTM B8
  • Conductor Shield: Semi-conducting cross-linked copolymer
  • Insulation: 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level
  • Insulation Shield: Stripable semi-conducting cross-linked copolymer
  • Copper Tape Shield: Helically wrapped 5 mil copper tape with 25% overlap
  • Grounding Conductor: 1 Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8
  • Filler: Wax paper filler
  • Binder: Poly glass tape
  • Overall Jacket: Polyvinyl Chloride (PVC)

 

 

Application

 

 

MV105 cables are highly versatile and reliable, making them suitable for a wide range of medium-voltage power transmission and distribution applications. These cables are designed to perform in both wet and dry environments, ensuring flexibility in various installation conditions. They can be used in conduits, ducts, troughs, trays, and even for direct burial, making them ideal for both indoor and outdoor installations.

3 core media voltage cable application

 

Feature

 

Copper 3 Core MV Wire

 

MV105 cable is made of Class B compression stranded bare copper conductors that meet ASTM B3 and ASTM B8 standards, providing excellent conductivity and mechanical strength for efficient power transmission. The conductor shield uses a semi-conductive cross-linked copolymer, which helps control electrical stress and ensures safe operation by providing a smooth surface for the insulation layer. The cable is insulated with 115 mil lead-free ethylene propylene rubber (NL-EPR) for excellent dielectric strength and flexibility. 

 

Certification

 

 

Our cables have passed UL, SAA, VDE, CE, CB, and other certifications. Among them, the UL certification number: E549302, which can be checked on the official website. Our company has corresponding certification for each region. We have 10+ years of experience in foreign trade export, exporting to 80+ countries around the world, and are familiar with the wire and cable specifications and standards of many countries.

UL certificated MV cable

 

Package

 

MV105 cable package

 

Factory

 

wire and cable factory

 

Dongguan Greater Wire & Cable Co., Ltd., is located in Dongguan City, Guangdong province. It integrates R&D, production, sales and maintenance, focusing on various wires and cables, and providing customized solutions for large-scale infrastructure such as airports, hospitals, factories, and schools in many regions around the world. With advanced production equipment and processes, complete testing equipment, and strong technical strength, the company has developed rapidly after years of hard work and the support of global customers, and has won a high reputation and market share in overseas markets.
Our cables and wires have passed SAA, UL, TUV, CE, and other standard certifications.Our products have gained tremendous traction in the international market and are frequently exported to regions such as Southeast Asia, Australia, the Middle East, Africa, America, and Europe, Sales cover more than 400 cities at home and abroad.

 

Case

 

wire and cable company

 

Partner

 

greater wire Partner

 

FAQ

 

Q: What is the difference between MV90 and MV105 cable?

A: MV90 cables typically have insulation rated for a maximum continuous operating temperature of 90°C (194°F). The "90" in MV90 refers to this temperature limit.
MV105 cables are rated for a higher continuous operating temperature of 105°C (221°F). The "105" indicates the temperature rating of the insulation.  

Q: What does MV cable stand for?

 

A:MV cable stands for Medium Voltage cable. It refers to electrical cables used for the transmission and distribution of electrical power at medium voltage levels, typically ranging from 1 kV (kilovolt) to 36 kV. These cables are used in power systems for both overhead and underground installations, including applications in industrial, commercial, and utility sectors.

 

 

Hot Tags: mv105 cable, China mv105 cable manufacturers, suppliers, factory, SAA Australia Flat 2C E Electrical TPS Cable, flexible cable, australia cable, ul standard xhhw xhhw 2 cable, 3 Core TPS Cable, CU XLPE STA Cable

3C copper MV Cable

Cond. Size Diameter over Ground Jacket Thickness Approx. OD Approx. Weight Max Pull Tension Min Bending Radius
Cond.  Insul. Insul. Shield
AWG inches inches inches No. x AWG mils inches lbs./MFT lbs. inches
2 0.283 0.550 0.610 1*6 80 1.549 1564 1593 10.8
1 0.322 0.589 0.649 1*4 80 1.633 1834 2009 11.4
1/0 0.362 0.629 0.689 1*4 80 1.719 2112 2534 12.0
2/0 0.405 0.672 0.732 1*4 110 1.872 2550 3194 13.1
3/0 0.456 0.723 0.783 1*3 110 1.982 3012 4027 13.9
4/0 0.512 0.779 0.839 1*3 110 2.103 3536 5078 14.7
250 0.558 0.834 0.894 1*3 110 2.222 4007 6000 15.6
350 0.661 0.937 0.997 1*2 110 2.445 5204 8400 17.1
500 0.789 1.065 1.125 1*1 110 2.721 6940 12000 19.0
750 0.968 1.253 1.313 1*0 135 3.177 9920 18000 22.2

 

All dimensions are nominal and subject to normal manufacturing tolerances 

Comply with ICEA S-93-639 Appendix C for jacket thickness determination 

Standard stock item

UL1072-E549302
UL 1072
UL1072-E549302
UL 1072

 

 

Send Inquiry