·Conductor: Soild bare copper per ASTM B3, Class B compressed stranded copper per ASTM B3 and B8, or 19-strand combination unilay copper per ASTM B3 and B787
·Insulation: Cross Linked Polyethylene (XLPE) Type RHH/RHW-2 or USE-2,High Heat,Moisture and Abrasion Resistant
·Voltage: 600V/1000V/2000V
Send Inquiry
Download
Description
Technical Parameters
Certification

Dongguan Greater Wire & Cable Co., Ltd. is one of the leading manufacturers and suppliers of rhh building wire for modular and prefabricated construction in China, also supports customized service. Please rest assured to wholesale durable rhh building wire for modular and prefabricated construction made in China here from our factory. If you have any enquiry about free sample, please feel free to email us.

 

RHH wire for indoor PVC conduit wiring

PRODUCT REAL SHOT

 

RHH wire for indoor PVC conduit wiring
RHH wire for electrical wireway installation
RHH cable for electrical wireway installation

RHH wire for electrical duct installation

Copper Fixed Wiring for Dry Interior Electrical Systems in Factory Built Building Projects
RHH Building Wire for Modular Construction can be used in dry interior electrical systems when the modular or prefabricated building design specifies UL44 RHH conductors. GERITEL WIRE supplies stranded copper wire with thermoset insulation for 90°C service, supporting fixed feeders and protected distribution pathways within factory-built structures. Prefabricated building RHH wire should be selected according to the final installation method and local electrical code rather than treated as a mobile-home feeder unless the required multiple listings are present. GERITEL WIRE offers modular building electrical wire with project printing, color, reel length and packaging customization for repeat production lines.
PRODUCT SPECIFICATIONS

 

RHH cable for electrical duct installation

Application and Description

 

GERITEL WIRE's USE-2 600 Volts or RHH/RHW-2 1000 Volts power cables are suited for use in wet and dry areas, conduits, ducts, troughs, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lb/ft maximum sidewall pressure.

SPECIFICATIONS
·ASTM B3 Soft or Annealed Copper Wire
·ASTM B8 Concentric-Lay-Stranded Copper Conductors
·ASTM B787 19 Wire Combination Unilay-Stranded Copper Conductors
·UL 44 Thermoset-Insulated Wires and Cables
·UL 854 Service Entrance Cable
·ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
·RoHS-2 (European Directive 2011/65/EU)

Table 1 – Weights and Measurements 

Cond. Size Strand Count Diameter Over Conductor Insul. Thickness Insulation Color Approx. OD Copper Weight Approx. Weight

AWG/Kcmil

No. of Strands inch mil inch lb/1000ft lb/1000ft
14 7 0.070

45

BK 0.161 12 20
12 Solid 0.080 45 BK 0.174 19 28
12 7 0.088 45 BK 0.179 20 28
10 7 0.113 45 BK 0.203 32 42
8 7 0.141 60 BK 0.259 95 67
6 7 0.177 60 BN 0.300 81 102
4 7 0.225 60 BK 0.345 128 153
3 7 0.252 60 BK 0.378 162 191
2 7 0.282 60 WE 0.403 205 244
1 19 0.322 80 BK 0.481 258 304
1/0 19 0.361 80 BK 0.522 325 390
2/0 19 0.405 80 GN 0.564 410 481
3/0 19 0.456 80 BK 0.616 518 598
4/0 19 0.512 80 GN 0.672 653 742
250 37 0.558 95 BK 0.748 771 884
300 37 0.610 95 BK 0.801 926 1023
350 37 0.661 95 BK 0.851 1081 1213
400 37 0.705 95 BK 0.896 1235 1345
500 37 0.789 95 BN 0.956 1544 1696
600 61 0.865 110 YW 1.085 1853 2028
750 61 0.968 110 GN 1.171 2315 2492
1000 61 1.117 110 BK 1.337 3088 3283
All dimensions are nominal and subject to normal manufacturing tolerances
◊ Cable marked with this symbol is a standard stock item
• TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.

Table 2 – Electrical and Engineering Data

Cond. Size Min Bending
Radius
Max Pull
Tension
DC Resistance @
25°C
AC Resistance @
75°C
Inductive Reactance
@ 60Hz
Allowable Ampacity
At 75°C
Allowable Ampacity
At 90°C

AWG/Kcmil

inch lb Ω/1000ft Ω/1000ft Ω/1000ft Amp Amp
14 0.6 32 2.631 3.170 0.058 20 25
12 0.7 52 1.662 2.002 0.054 25 30
12 0.7 52 1.662 2.002 0.054 25 30
10 0.8 83 1.040 1.253

0.050

35 40
8 1.0 132 0.653 0.786 0.052 50 55
6 1.2 209 0.411 0.495 0.051 65 75
4 1.4 333 0.258 0.310 0.048 85 95
3 1.5 420 0.205 0.246 0.047 100 115
2 1.6 530 0.162 0.195 0.046 115 130
1 1.9 669 0.128 0.154 0.045 130 145
1/0 2.1 844 0.102 0.122 0.044 150 170
2/0 2.3 1064 0.081 0.097 0.043 175 195
3/0 2.5 1342 0.064 0.078 0.042 200 225
4/0 2.7 1692 0.051 0.062 0.041 230 260
250 3.0 2000 0.043 0.053 0.041 255 290
300 3.2 2400 0.036 0.045 0.041 285 320
350 3.4 2800 0.031 0.039 0.040 310 350
400 3.6 3200 0.027 0.035 0.040 335 380
500 3.8 4000 0.022 0.029 0.039 380 430
600 5.4 4800 0.018 0.025 0.039 420 475
750 5.9 6000 0.014 0.022 0.038 475 535
1000 6.7 8000 0.011 0.018 0.037 545 615
• Ampacities based upon 2023 NEC Table 310.16 and do not take into account the overcurrent protection limitations in NEC 240.4(D) of 15 Amps for 14 AWG CU, 20
Amps for 12 AWG CU, and 30 Amps for 10 AWG CU (independent of the conductor temperature rating and stranding if size is present in table). Also, see NEC sections
310.15 and 110.14(C) for additional requirements.
• Inductive Reactance is based on non-ferrous conduit with one diameter spacing center-to-center.
CERTIFICATIONS

 

RHH wire for dry raceway installation

PACKAGING

 

RHH cable for dry raceway installation

Roll

RHH wire for recognized raceway wiring

Small Wooden Reel

RHH cable for recognized raceway wiring

Large Wooden Reel

APPLICATION

 

RHH wire for panel to panel wiring
Underground Conduit Installation
RHH cable for panel to panel wiring
Conduit Wiring
RHH wire for switchgear feeder wiring
Feeder Circuit Wiring
CASE

 

RHH wire for switchboard feeder wiring

Tesla Gigafactory Texas

RHH cable for switchgear feeder wiring

Stanford University California USA

RHH cable for switchboard feeder wiring

Mayo Clinic Hospital, Saint Marys Campus

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

RHH wire for panelboard feeder wiring
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

RHH cable for panelboard feeder wiring
 
RHH wire for electrical cabinet wiring
 
RHH cable for electrical cabinet wiring
 
RHH wire for control panel power wiring
 
RHH cable for control panel power wiring
 
RHH wire for motor control center wiring
 
GLOBAL CERTIFICATIONS

 

RHH cable for motor control center wiring

CUSTOMER PHOTOS
 

RHH wire for fixed equipment power wiring

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

RHH cable for fixed equipment power wiring
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

RHH wire for indoor feeder installation
RHH wire for low voltage switchgear
RHH cable for low voltage switchgear
RHH wire for switchboard wiring
RHH cable for indoor branch circuit installation
RHH wire for main switchboards
RHH cable for indoor feeder installation
RHH wire for distribution switchboards
RHH wire for indoor branch circuit installation
RHH wire for commercial building conduit wiring
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

RHH cable for commercial building conduit wiring
FAQ

 

Is RHH wire the same as PV wire?
No. PV wire is a separate product category designed for photovoltaic circuit conditions. renewable energy RHH wire can be used in appropriate building-side or equipment-room distribution, but buyers should not treat standard RHH as a replacement for PV wire unless the exact product carries the required ratings.
Can RHH wire be used in wind power facilities?
RHH can support protected dry-location power distribution in wind-farm buildings, control rooms or balance-of-plant facilities when specified by the electrical design. GERITEL WIRE supplies RHH wire for wind power facilities for fixed conduit, panel and feeder applications.
Can RHH cable be used in microgrid projects?
Yes, for suitable protected fixed distribution circuits within microgrid electrical rooms or building infrastructure. GERITEL WIRE supplies RHH cable for microgrids with copper conductors, thermoset insulation and project-specific identification for EPC and equipment integration programs.
Can RHH wire be used in EV charging infrastructure?
RHH can be considered for protected facility-side feeders serving EV charging equipment when the electrical design specifies this conductor type. GERITEL WIRE supplies RHH wire for EV charging facilities for dry-location conduit and distribution systems, subject to local code and equipment requirements.

 

Hot Tags: rhh building wire for modular and prefabricated construction, China rhh building wire for modular and prefabricated construction manufacturers, suppliers, factory

Send Inquiry