6/10kV FL2XCYRY Airfield Lighting Cable

6/10kV FL2XCYRY Airfield Lighting Cable
Details:
Low voltage cables to medium voltage cables
Covering a wide range of applications,
used in airport lighting series circuits,
aircraft, and their computer systems
All cables meet FAA standards
Send Inquiry
Download
Description
Technical Parameters
Certification
FL2XCY airfield cable

 

6/10kV FL2XCYRY Airfield Lighting Cable
 
  • Conductor: Stranded bare copper conductor

  • Inner Semi-Conducting Layer: Extruded semi-conducting compound

  • Insulation: XLPE (Cross-linked Polyethylene)

  • Outer Semi-Conducting Layer: Extruded semi-conducting compound

  • Shield: Concentric layer of bare copper wires, counter helix of copper tape

  • Inner Sheath: PVC (Polyvinyl chloride)

  • Armour: GSWA (Galvanised steel wire armour)

  • Outer Sheath: PVC (Polyvinyl chloride) - Flame retardant, UV & Oil resistant

  • Rated Voltage Uo/U (Um): 6/10kV

  • Temperature Rating Operating: -40°C to +90°C

  • Minimum Bending Radius: 15 x Overall Diameter

  • Standards: ENV 50213, IEC 50602-2

     

 

Application

 

 

FL2XCYRY airfield lighting cable is an enhanced 6/10kV airport lighting trunk cable upgraded from FL2XCY, designed for complex environments that require additional mechanical protection. The difference from FL2XCY is that this model adds a layer of galvanized steel wire armor (GSWA) between the inner and outer sheaths, which significantly enhances the cable's compressive and tensile properties. It is particularly suitable for underground laying, heavy-loaded areas, or places susceptible to mechanical impact, such as runway intersections, taxiway edges, and apron lighting connection areas.

airfield lighting cables application

 

Feature

 

FL2XCYRY Airfield Lighting Cable

 

FL2XCYRY airfield cable retains all the key electrical structures of FL2XCY - stranded bare copper conductors, XLPE insulation, double-layer semi-conductive shielding, and concentric copper wire + copper tape composite shielding to ensure uniform electric fields and low electromagnetic interference. Its outer sheath is made of PVC material with flame retardant, UV resistance, and oil resistance, ensuring stable operation in severe weather and high-intensity sunlight.

 

 

 

Package

 

Airfield lighting cable package

 

Factory

 

Airfield lighting cable factory

 

At Greater Wire Manufacturer, our mission is clear: to empower industries through reliable, high-performance wire and cable solutions. We aim to be a global leader by continuously innovating, maintaining superior quality, and exceeding customer expectations. Our vision is to build an intelligent manufacturing ecosystem where technology, quality, and customer service blend seamlessly. As markets evolve and applications become more complex, we remain committed to developing solutions that are not only functional but also sustainable, efficient, and future-ready.

 

 

 

 

Case

 

Greater Wire and Cable Company cases

 

Partner

 

Greater Wire Partner

 

 

 

Hot Tags: 6/10kv fl2xcyry airfield lighting cable, China 6/10kv fl2xcyry airfield lighting cable manufacturers, suppliers, factory

FL2XCYRY Cable

NUMBER OF CORES

NOMINAL CROSS SECTIONAL AREA

mm2

NOMINAL INSULATION THICKNESS
mm
NOMINAL SHEATH THICKNESS
mm
NOMINAL OVERALL DIAMETER
mm
NOMINAL WEIGHT
kg/km
1 6 3.5 1.4 20.5 710

 

 

 

Send Inquiry