6/10kV FL2XCY Airfield Cable

6/10kV FL2XCY Airfield Cable
Details:
Low voltage cables to medium voltage cables
Covering a wide range of applications,
used in airport lighting series circuits,
aircraft, and their computer systems
All cables meet FAA standards
Send Inquiry
Download
Description
Technical Parameters
Certification
FL2XCY airfield cable

 

6/10kV FL2XCY Airfield Cable
 
  • Conductor: Stranded bare copper conductor

  • Inner Semi-Conducting Layer: Extruded semi-conducting

  • Compound Insulation: XLPE (Cross-linked Polyethylene)

  • Outer Semi-Conducting Layer: Extruded semi-conducting compound

  • Shield: Concentric layer of bare copper wires, counter helix of copper tape

  • Outer Sheath: PVC (Polyvinyl chloride) - UV & Oil Resistant

  • Sheath Colour: Red

  • Rated Voltage Uo/U (Um): 6/10kV

  • Temperature Rating Operating: -40°C to +90°C

  • Minimum Bending Radius: 15 x Overall Diameter

  • Standards: ENV 50213, IEC 50602-2

     

     

     

     

     

     

     

 

Application

 

 

FL2XCY 6/10kV airfield lighting cable is mainly used in the primary power supply line of the airport lighting system, especially in the series circuit between the constant current regulator (CCR) and the isolation transformer, and between the isolation transformers. At the same time, the cable has good flexibility, and the minimum bending radius is 15 times the overall diameter, which is convenient for on-site wiring construction and maintenance. FL2XCY series products have been widely used in major civil and military airports at home and abroad, and have become one of the key infrastructure components to ensure the reliable operation of airport lighting systems.

airfield lighting cables application

 

Feature

 

FL2XCY Cables

 

6/10kV FL2XCY airfield cable uses multiple strands of bare copper conductors with excellent electrical conductivity, and is equipped with extruded semi-conductive layers on both the inner and outer layers to improve the uniformity of the electric field distribution and the stability of the overall cable. It can withstand harsh operating temperatures from -40°C to +90°C. This type of cable complies with ENV 50213 and IEC 50602-2 standards and is widely used in airport lighting systems with extremely high reliability requirements. It is an important basis for ensuring the continuous and stable operation of runway lighting.

 

 

 

Package

 

Airfield lighting cable package

 

Factory

 

Airfield lighting cable factory

 

Greater Wire Manufacturer actively collaborates with engineering firms, contractors, and infrastructure developers across a wide range of industries. Through long-term partnerships, we support national and regional projects involving airport construction, renewable energy installations, smart building systems, and electric mobility. We provide customized cable solutions tailored to each project's unique technical and regulatory demands. Our team participates in industry exhibitions, tenders, and innovation programs to stay aligned with the needs of global infrastructure expansion.

 

 

 

 

Case

 

Greater Wire and Cable Company cases

 

Partner

 

Greater Wire Partner

 

 

 

Hot Tags: 6/10kv fl2xcy airfield cable, China 6/10kv fl2xcy airfield cable manufacturers, suppliers, factory, SAA Australia Flat 2C E Electrical TPS Cable, silicone insulated wire, sdi cable, 600V UL1015 MTW Hook Up Wire, multicore flexible cable, Super Flexible Welding Cable

FL2XCY cable

NUMBER OF CORES

NOMINAL CROSS SECTIONAL AREA

mm2

NOMINAL INSULATION THICKNESS
mm
NOMINAL ARMOUR THICKNESS
mm
NOMINAL SHEATH THICKNESS
mm
NOMINAL OVERALL DIAMETER
mm
NOMINAL WEIGHT
kg/km
1 6 3.5 6 1.4 15.6 420

 

 

 

Send Inquiry