1.5mm2 Stranded Conduit Wire 1C V-90 PVC Copper Cable

1.5mm2 Stranded Conduit Wire 1C V-90 PVC Copper Cable
Details:
·Insulation:V-90 PVC
·Plain annealed copper conductor to AS/NZS 1125
·Maximum continuous operating temperature:75℃
·PVC INSULATED ONLY CABLE TO AS/NZS 5000.1
·Colours: Red,Black,White,Blue,Green/Yellow
Send Inquiry
Download
Description
Technical Parameters
Certification

1.5mm2 V90 single core cable

PRODUCT REAL SHOT

 

1.5 mm² V-90 building wire
1.5mm² PVC insulated single core cable
1.5 sq mm copper building wire

1.5mm2 conduit wire

Easy-Routing Building Wire for Panels and Protected Conduit
1.5mm2 stranded building wire combines a seven-wire plain annealed copper conductor with V-90 PVC insulation for protected electrical installation work. The stranded construction supports cleaner bends than a solid conductor when routing a single core conduit wire through panels, apparatus, junction areas and enclosed wiring systems. This 600/1000V copper cable is produced to AS/NZS 5000.1 with conductor requirements aligned to AS/NZS 1125 and a 75°C maximum continuous operating temperature. GERITEL WIRE can arrange standard circuit colours, green/yellow earth identification, meter marking, custom printing and coil or reel packing. Installation design should verify load, protective device, terminal size and conduit conditions.
PRODUCT SPECIFICATIONS

 

1.5mm2 copper conduit wire

Applications

 

For seperate earth conductors. For switchboard and control panel wiring. For fixed wiring within other enclosures or apparatus where the cable is not accessible without the use of tools. For use where improved aging properties to those of 75°C PVC are required because of higher ambient temperatures. Suitable for glanding

SPECIFICATIONS
CONDUCTOR

Plain annealed copper conductor to AS/NZS 1125
Maximum continuous operating temperature: 75°C

Can also be operated at temperatures up to 90°C when not exposed to mechanical deformation (see AS/NZS 3008.1)

INSULATION V-90 PVC
Colours: Red, Black, White, Blue, Green/Yellow

Conductor

Cable

Min.

installed

bending

radius

mm

Nominal

C.S.A

mm²

Nominal

diameter

of wires
No/mm

Nominal

diameter

mm

Nominal

insulation

thickness

mm

Overall diameter

Approx.

mass

kg/100 m

Minimum

mm

Maximum

mm

1.0* 1/11.3 1.13 0.8 2.6 2.8 1.7 10
1.5 7/0.50 1.5 0.8 3.0 3.2 2.2 15
2.5* 1/1.78 1.78 0.8 3.3 3.5 3.3 15
2.5 7/0.67 2.0 0.8 3.5 3.7 3.4 15
4 7/0.85 2.6 1.0 4.5 4.6 5.4 20
6 7/1.04 3.1 1.0 5.1 5.2 7.6 20
10 7/1.35 4.1 1.0 6.0 6.1 12 25
16 7/1.70 5.1 1.0 7.1 7.2 18 30
25 19/1.35 6.8 1.2 9.1 9.3 27 35
35 19/1.53 7.7 1.2 10.0 10.1 36 40
50 19/1.78 8.9 1.4 11.6 11.9 51 50
70 19/2.14 10.7 1.4 13.4 13.5 70 55
95 19/1.45 12.5 1.6 15.9 15.9 98 65
120 37/2.03 14.2 1.6 17.4 17.4 120 70
150 37/2.25 15.8 1.8 19.5 19.5 148 80
185 37/2.52 17.6 2.0 21.7 21.7 185 90

Conductor

nominal

C.S.A.

mm²

Current rating (a) Electrical characteristics
Three phase Single phase

Maximum D.C.

resistance

at20°C

Ω/km

Reactance per core

(Trefoil, Touching)

Ω/km

In conduit

in air A

Underground

in duct A

In conduitinair A

Underground

in duct A

1.0* 11 16 13 18 18.1 0.119
1.5 14 20 16 24 13.6 0.111
2.5* 20 28 22 33 7.41 0.102
2.5 20 28 22 33 7.41 0.102
4 26 37 30 42 4.61 0.102
6 34 46 38 53 3.08 0.0967
10 47 61 53 71 1.83 0.0906
16 62 80 71 91 1.15 0.0861
25 87 105 97 120 0.727 0.0853
35 100 125 115 145 0.524

0.0826

50 125 150 140 170 0.387 0.0797
70 155 185 175 210 0.268 0.0770
95 185 225 210 260 0.193 0.0766
120 220 260 250 295 0.153 0.0743
150 250 290 280 335 0.124 0.0745
185 285 335 325 380 0.0991 0.0744
CERTIFICATIONS

 

1.5mm2 0.6/1kV building wire

1.5mm2 600/1000V single core wire

PACKAGING

 

1.5mm2 AS/NZS 5000.1 cable

Roll

1.5mm2 AS/NZS 1125 copper wire

Plastic Reel

1C x 1.5mm2 V90 PVC cable

Small Wooden Reel

APPLICATION

 

1 x 1.5 mm² building wire
Industrial Control Panel
1.5mm2 unsheathed copper cable
Renewable Energy Power Connection
1.5mm2 fixed wiring cable

Switchboard Wiring

 

CASE

 

1.5mm2 switchboard wiring cable

Adelaide Airport Switchboard Upgrade

1.5mm2 control panel wiring cable

Industrial Main Switchboard Power Distribution

1.5mm2 building wire supplier

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

1.5mm2 building wire manufacturer
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

1.5mm2 V90 copper wire price
 
1.5mm2 V90 cable datasheet
 
V90 conduit wire
 
PVC conduit wire
 
CU conduit wire
 
1C PVC V90 cable
 
GLOBAL CERTIFICATIONS

 

1 core V90 PVC cable

CUSTOMER PHOTOS
 

single core unsheathed cablev

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

unsheathed copper cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

non sheathed single core cable
PVC insulated only cable
single insulated copper cable
0.6/1kV single core cable
600/1000V single core cable
1kV building wire
0.6/1kV building wire
600/1000V building wire
0.6/1kV conduit wire
600/1000V conduit wire
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

AS/NZS 5000.1 cable
FAQ

 

What is the voltage rating of this single core cable?
The 0.6/1kV single core cable is rated 600/1000V. Voltage rating does not determine the allowable current by itself, so the installer must also evaluate conductor size, route length, grouping, ambient temperature and installation method. GERITEL WIRE can provide dimensional and conductor information for the design review.
What conductor material is used in the cable?
The cable uses a plain annealed copper conductor manufactured to the relevant AS/NZS 1125 requirements. GERITEL WIRE can confirm the strand construction for each nominal size, provide batch inspection records when agreed, and maintain the approved copper and dimensional specification throughout the production order.
Which standards apply to this V90 building wire?
AS/NZS 5000.1 building wire is the product basis, while the copper conductor is specified to AS/NZS 1125. Installation must also follow the current wiring rules and project requirements. GERITEL WIRE can prepare the quotation, technical datasheet and product marking around the confirmed standard edition and buyer documentation list.
Is the continuous operating temperature 75°C or 90°C?
For the GERITEL WIRE specification discussed here, the stated limit is a 75°C continuous operating temperature. Some market pages describe V-90 products using 90°C terminology, but actual permissible conductor temperature can depend on the cable design and installation conditions. Use the approved GERITEL datasheet and licensed design calculations for the final project.

 

Hot Tags: 1.5mm2 stranded conduit wire 1c v-90 pvc copper cable, China 1.5mm2 stranded conduit wire 1c v-90 pvc copper cable manufacturers, suppliers, factory, 0 6 1KV Single Core Building Cable, 0 6 1KV Single Core Flexible Cable, single core building cable

Send Inquiry