95mm 0.6/1kV Flexible Cable With Colour Options

95mm 0.6/1kV Flexible Cable With Colour Options
Details:
·Conductor: Flexible bunched annealed copper conductor to AS/NZS 1125 (Class 5)
·Insulation: V-90 PVC
·Approvals: Suitable for fixed applications only in accordance with AS/NZS 3000 +AS/NZS 5000.1
·Maximum operating temperature: +90℃
·Minimum operating temperature: 0℃
Send Inquiry
Download
Description
Technical Parameters
Certification

95mm flexible cable 0.6/1kV

PRODUCT REAL SHOT

 

95mm2 flexible cable 600/1000V
95 mm² single core flexible cable
1 x 95mm2 flexible cable

1C 95mm flexible cable

Blue Red Black White and Earth Colour Options
This 95mm colour coded flexible cable provides a practical solution for colour options where a flexible conductor is required but the completed installation remains fixed. Its bunched annealed copper conductor meets AS/NZS 1125 Class 5, and the V-90 PVC insulation is produced to AS/NZS 5000.1 for 0.6/1kV service. The 95mm 0.6/1kV single core cable is suitable for glanding, has a 0°C minimum operating temperature and a +90°C maximum operating temperature, and is tested for flame propagation to AS/NZS 1660.5.6. GERITEL WIRE offers blue, red, black, white, green, yellow and green/yellow insulation colours. For protective earthing, specify the green/yellow 95mm green yellow protective earth option and confirm size, gland and termination details with the project engineer.
PRODUCT SPECIFICATIONS

 

95 sq mm flexible copper cable

Cable description

 

Flexible PVC insulated to AS/NZS 5000.1

Applications

 

For use as protective earth in electrical installations. For use where improved aging properties to those of 75°C PVC are required because of higher ambient temperatures. Suitable for glanding.

SPECIFICATIONS
Approvals Suitable for fixed applications only in accordance with AS/NZS 3000 +AS/NZS 5000.1
Behaviour in flame and fire Flame propagation=AS/NZS 1660.5.6
Temperature range

Maximum operating temperature: +90°C

Minimum operating temperature: 0 °C

Minimum bending radius

Installed cables: 4D

During installation: 6D

Resistance to

Chemical exposure: Occasional

Mechanical impact: Light

Water exposure:  Occasional condensation

Solar radiation and weather exposure: Occasional

Cable design

Conductor: Flexible bunched annealed copper conductor to AS/NZS 1125 (Class 5)

Insulation: V-90 PVC

Installation conditions

Industrial equipment

In conduit

Machines

Internal wiring

 For fixed installation

Conductor

Cable

Min.

installed

bending

radius

mm

Nominal

C.S.A

mm²

Nominal

diameter
mm

Nominal

nsulation

thickness

mm

Overall diameter

Approx.

mass

kg/100 m

Minimum

mm

Maximum

mm

1.0 1.3 0.8 2..9 3.0 1.6 12
1.5 1.5 0.8 3.1 3.2 2.0 13
2.5 2.0 0.8 3.6 3.7 3.0 15
4 2.7 1.0 4.6 4.7 5.4 19
6 3.5 1.0 5.4 5.6 8.0 22
10 4.2 1.0 6.1 6.3 11 25
16 5.3 1.0 7.2 7.4 16 30
25 6.7 1.2 8.9 9.1 25 40
35 7.9 1.2 10.1 10.3 34 45
50 9.5 1.4 12.1 12.3 49 50
70 11.3 1.4 13.9 14.2 67 60
95 13.0 1.6 16.0 16.2 89 65
120 14.7 1.6 17.6 17.9 112 75
150 16.5 1.8 19.8 20.2 140 85
185 18.2 2.0 21.9 22.2 170 90
240 20.9 2.2 25 25.4 223 105
300 23.5 2.4 27.9 28.4 279 115
400 26.9 2.6 31.7 32.2 365 130

Electrical characteristics

Conductor

nominal

C.S.A.

mm²

MaximumD.C.

resistance

at 20°C

Ω/km

Reactance per core

(Trefoil, Touching)

Ω/km

1.0 19.5 0.116
1.5 13.3 0.109
2.5 7.98 1.101
4 4.95 0.100
6 3.30 0.0954
10 1.91 0.0876
16 1.21 0.0835
25 0.780 0.0829
35 0.554 0.0801
50 0.386 0.0799
70 0.272 0.0773
95 0.206 0.0771
120 0.161 0.0753
150 0.129 0.0755
185 0.106 0.0754
240 0.0801 0.0749
300 0.0641 0.0747
400 0.0486 0.0738
CERTIFICATIONS

 

95mm V-90 PVC flexible cable

95mm AS/NZS 5000.1 flexible cable

PACKAGING

 

95mm Class 5 flexible copper cable

Roll

95mm bunched copper flexible wire

Plastic Reel

95mm fixed installation flexible cable

Small Wooden Reel

APPLICATION

 

95mm flexible cable for glanding
Industrial Control Panel
95mm 90°C flexible PVC cable
Renewable Energy Power Connection
95mm protective earth flexible cable

Switchboard Wiring

 

CASE

 

95mm green yellow flexible earth cable

Adelaide Airport Switchboard Upgrade

95mm RV style flexible wire 0.6/1kV

Industrial Main Switchboard Power Distribution

Class 5 flexible copper cable

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

Class 5 flexible copper wire
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

fine stranded single core cable
 
fine stranded copper flexible wire
 
bunched copper flexible cable
 
best supplier for 0.6/1kV flexible cable
 
bunched annealed copper cable
 
multiple stranded flexible copper cable
 
GLOBAL CERTIFICATIONS

 

flexible stranded copper wire

CUSTOMER PHOTOS
 

unsheathed single core flexible cable

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

unsheathed flexible building wire
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

PVC insulated only flexible cable
single insulated flexible copper cable
low voltage single core flexible cable
low voltage flexible copper wire
one core flexible copper cable
one core PVC insulated flexible wire
flexible LV building wire
flexible LV single core cable
Australian standard flexible cable
New Zealand standard flexible cable
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

AS/NZS flexible single core cable
FAQ

 

Can I use the same size in free air and in conduit?
Not automatically. Heat dissipation changes with installation method, so a cable may carry less current in conduit or grouped wiring than in free air. Select the single core flexible cable ampacity from the correct reference method. GERITEL WIRE uses production monitoring and inspection controls to help maintain dimensional and electrical consistency. The confirmed product is a 0.6/1kV V-90 PVC insulated Class 5 copper cable for fixed applications only. GERITEL WIRE supports project datasheets, sample confirmation, cable marking and export packing. Useful specification terms are flexible cable current rating, AS/NZS 5000.1 flexible cable and Class 5 copper conductor.
How does ambient temperature affect the cable?
Higher ambient temperature reduces the thermal margin of V-90 PVC insulation and may require a larger conductor. Confirm the V-90 flexible cable temperature assumptions and apply the correct correction factor before final sizing. With international export experience, GERITEL WIRE can coordinate product documents, packing and shipping requirements. The confirmed product is a 0.6/1kV V-90 PVC insulated Class 5 copper cable for fixed applications only. GERITEL WIRE can provide production inspection records and batch identification for project orders. Useful specification terms are 90°C flexible PVC cable, 0°C minimum operating temperature and V-90 insulated cable.
Can this cable carry high starting current?
It can carry short-duration starting current when the conductor and protection are correctly designed, but motor starting voltage drop and thermal duty must be checked. Use the flexible motor connection cable data in the complete circuit calculation. GERITEL WIRE can support OEM and project buyers with specification review, quotation and after-sales investigation. The confirmed product is a 0.6/1kV V-90 PVC insulated Class 5 copper cable for fixed applications only. GERITEL WIRE supports standard colour options and project-specific lengths subject to order requirements. Useful specification terms are flexible cable current rating, AS/NZS 5000.1 flexible cable and Class 5 copper conductor.
How do I check short-circuit withstand?
Short-circuit withstand depends on conductor area, material, initial temperature, final temperature and fault duration. The protective device must clear within the calculated limit. GERITEL WIRE can provide the flexible copper conductor data needed by the engineer. GERITEL WIRE can review the circuit data and provide a model-specific datasheet before quotation. The confirmed product is a 0.6/1kV V-90 PVC insulated Class 5 copper cable for fixed applications only. GERITEL WIRE can help coordinate the cable, gland, lug and fixed-installation requirements. Useful specification terms are 0.6/1kV single core flexible cable, V-90 PVC flexible cable and AS/NZS 5000.1 cable.

 

Hot Tags: 95mm 0.6/1kv flexible cable with colour options, China 95mm 0.6/1kv flexible cable with colour options manufacturers, suppliers, factory, 0 6 1KV Single Core Building Cable, 0 6 1KV Single Core Flexible Cable, single core building cable

Send Inquiry