120mm Flexible Copper Cable To AS/NZS 5000.1

120mm Flexible Copper Cable To AS/NZS 5000.1
Details:
·Conductor: Flexible bunched annealed copper conductor to AS/NZS 1125 (Class 5)
·Insulation: V-90 PVC
·Approvals: Suitable for fixed applications only in accordance with AS/NZS 3000 +AS/NZS 5000.1
·Maximum operating temperature: +90℃
·Minimum operating temperature: 0℃
Send Inquiry
Download
Description
Technical Parameters
Certification

120mm flexible cable 0.6/1kV

PRODUCT REAL SHOT

 

120mm2 flexible cable 600/1000V
120 mm² single core flexible cable
1 x 120mm2 flexible cable

1C 120mm flexible cable

Class 5 Bunched Copper Cable for Reliable Fixed Connections
GERITEL WIRE 120mm 0.6/1kV flexible cable is manufactured with a flexible bunched annealed copper conductor complying with AS/NZS 1125 Class 5 and V-90 PVC insulation to AS/NZS 5000.1. Rated 0.6/1kV, the cable is intended for fixed applications in accordance with AS/NZS 3000 and is suitable for glanding. The 120mm V-90 PVC flexible wire operates from 0°C to +90°C and offers improved ageing performance compared with 75°C PVC in higher ambient temperatures. Blue, red, black, white, green, yellow and green/yellow colours are available; select the green/yellow 120mm Class 5 flexible copper cable for protective earth use. Flame propagation is assessed to AS/NZS 1660.5.6, and GERITEL WIRE can support project marking, packing and technical-document review.
PRODUCT SPECIFICATIONS

 

120 sq mm flexible copper cable

Cable description

 

Flexible PVC insulated to AS/NZS 5000.1

Applications

 

For use as protective earth in electrical installations. For use where improved aging properties to those of 75°C PVC are required because of higher ambient temperatures. Suitable for glanding.

SPECIFICATIONS
Approvals Suitable for fixed applications only in accordance with AS/NZS 3000 +AS/NZS 5000.1
Behaviour in flame and fire Flame propagation=AS/NZS 1660.5.6
Temperature range

Maximum operating temperature: +90°C

Minimum operating temperature: 0 °C

Minimum bending radius

Installed cables: 4D

During installation: 6D

Resistance to

Chemical exposure: Occasional

Mechanical impact: Light

Water exposure:  Occasional condensation

Solar radiation and weather exposure: Occasional

Cable design

Conductor: Flexible bunched annealed copper conductor to AS/NZS 1125 (Class 5)

Insulation: V-90 PVC

Installation conditions

Industrial equipment

In conduit

Machines

Internal wiring

 For fixed installation

Conductor

Cable

Min.

installed

bending

radius

mm

Nominal

C.S.A

mm²

Nominal

diameter
mm

Nominal

nsulation

thickness

mm

Overall diameter

Approx.

mass

kg/100 m

Minimum

mm

Maximum

mm

1.0 1.3 0.8 2..9 3.0 1.6 12
1.5 1.5 0.8 3.1 3.2 2.0 13
2.5 2.0 0.8 3.6 3.7 3.0 15
4 2.7 1.0 4.6 4.7 5.4 19
6 3.5 1.0 5.4 5.6 8.0 22
10 4.2 1.0 6.1 6.3 11 25
16 5.3 1.0 7.2 7.4 16 30
25 6.7 1.2 8.9 9.1 25 40
35 7.9 1.2 10.1 10.3 34 45
50 9.5 1.4 12.1 12.3 49 50
70 11.3 1.4 13.9 14.2 67 60
95 13.0 1.6 16.0 16.2 89 65
120 14.7 1.6 17.6 17.9 112 75
150 16.5 1.8 19.8 20.2 140 85
185 18.2 2.0 21.9 22.2 170 90
240 20.9 2.2 25 25.4 223 105
300 23.5 2.4 27.9 28.4 279 115
400 26.9 2.6 31.7 32.2 365 130

Electrical characteristics

Conductor

nominal

C.S.A.

mm²

MaximumD.C.

resistance

at 20°C

Ω/km

Reactance per core

(Trefoil, Touching)

Ω/km

1.0 19.5 0.116
1.5 13.3 0.109
2.5 7.98 1.101
4 4.95 0.100
6 3.30 0.0954
10 1.91 0.0876
16 1.21 0.0835
25 0.780 0.0829
35 0.554 0.0801
50 0.386 0.0799
70 0.272 0.0773
95 0.206 0.0771
120 0.161 0.0753
150 0.129 0.0755
185 0.106 0.0754
240 0.0801 0.0749
300 0.0641 0.0747
400 0.0486 0.0738
CERTIFICATIONS

 

120mm V-90 PVC flexible cable

120mm AS/NZS 5000.1 flexible cable

PACKAGING

 

120mm Class 5 flexible copper cable

Roll

120mm bunched copper flexible wire

Plastic Reel

120mm fixed installation flexible cable

Small Wooden Reel

APPLICATION

 

120mm flexible cable for glanding
Industrial Control Panel
120mm 90°C flexible PVC cable
Renewable Energy Power Connection
120mm protective earth flexible cable

Switchboard Wiring

 

CASE

 

120mm green yellow flexible earth cable

Adelaide Airport Switchboard Upgrade

120mm RV style flexible wire 0.6/1kV

Industrial Main Switchboard Power Distribution

AS/NZS flexible building wire

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

flexible conduit wire
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

V90 conduit wire
 
flexible switchboard wire
 
flexible control panel wire
 
flexible panel wiring cable
 
switchboard flexible cable
 
control cabinet flexible wire
 
GLOBAL CERTIFICATIONS

 

fixed wiring flexible cable

CUSTOMER PHOTOS
 

fixed installation flexible wire

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

glandable single core flexible cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

single core cable suitable for glanding
90°C PVC flexible cable
single core flexible cable for fixed wiring
single core flexible cable for electrical installations
single core flexible cable for switchboard wiring
single core flexible cable for control panel wiring
single core flexible cable with V-90 PVC insulation
single core flexible cable with Class 5 copper conductor
single core flexible cable to AS/NZS 5000.1
single core flexible cable rated 0.6/1kV
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

single core flexible wire for fixed wiring
FAQ

 

How do I check short-circuit withstand?
Short-circuit withstand depends on conductor area, material, initial temperature, final temperature and fault duration. The protective device must clear within the calculated limit. GERITEL WIRE can provide the flexible copper conductor data needed by the engineer. GERITEL WIRE can review the circuit data and provide a model-specific datasheet before quotation. The confirmed product is a 0.6/1kV V-90 PVC insulated Class 5 copper cable for fixed applications only. GERITEL WIRE can help coordinate the cable, gland, lug and fixed-installation requirements. Useful specification terms are 0.6/1kV single core flexible cable, V-90 PVC flexible cable and AS/NZS 5000.1 cable.
Is the 400mm² size always better for high current?
No. Oversizing increases cost, bend radius, terminal size and installation effort. Several parallel smaller conductors may be practical in some designs, but current sharing and route layout must be engineered. Compare the 400mm² flexible cable with the complete system design. GERITEL WIRE supports technical review, sample confirmation and documented production requirements for project orders. The confirmed product is a 0.6/1kV V-90 PVC insulated Class 5 copper cable for fixed applications only. GERITEL WIRE can prepare technical documentation against the confirmed purchase specification. Useful specification terms are 400mm flexible cable 0.6/1kV, AS/NZS 5000.1 flexible cable and Class 5 copper conductor. For the 400mm² size, the applicable SAA certificate is SAA241317, which covers 25mm²–630mm². GERITEL WIRE can include the applicable SAA certificate number in the quotation and provide a certificate copy for project-document review.
Can I use this cable as a neutral conductor?
It may be used as a circuit conductor only when the colour, size, installation method and project standard permit it. Do not use green/yellow for neutral or active functions; that colour is for protective earth. GERITEL WIRE can supply blue, black, red, white and other specified colours for approved circuit identification. The conductor is flexible bunched annealed copper manufactured to AS/NZS 1125 Class 5. GERITEL WIRE can review the application, size, colour, gland and termination details before quotation. Useful specification terms are AS/NZS 1125 Class 5 conductor, bunched annealed copper conductor and single core flexible cable.
Can it be used as a protective earth conductor?
Yes. Protective earth is a confirmed application for this flexible V-90 PVC cable. Specify green/yellow insulation, select the cross-sectional area from the earthing design and install it as a fixed conductor under AS/NZS 3000. GERITEL WIRE can review the size, marking, gland and termination requirements before production. For protective earth use, specify the green/yellow colour and follow AS/NZS 3000 and the project earthing design. GERITEL WIRE supports project datasheets, sample confirmation, cable marking and export packing. Useful specification terms are flexible protective earth cable, green/yellow V-90 cable and AS/NZS 3000 fixed installation.

 

Hot Tags: 120mm flexible copper cable to as/nzs 5000.1, China 120mm flexible copper cable to as/nzs 5000.1 manufacturers, suppliers, factory, 0 6 1KV Single Core Building Cable, 0 6 1KV Single Core Flexible Cable, single core building cable

Send Inquiry