1.0mm2 Solid Copper V90 Building Wire 0.6/1kV AS/NZS 5000.1

1.0mm2 Solid Copper V90 Building Wire 0.6/1kV AS/NZS 5000.1
Details:
·Insulation:V-90 PVC
·Plain annealed copper conductor to AS/NZS 1125
·Maximum continuous operating temperature:75℃
·PVC INSULATED ONLY CABLE TO AS/NZS 5000.1
·Colours: Red,Black,White,Blue,Green/Yellow
Send Inquiry
Download
Description
Technical Parameters
Certification

1.0mm2 V90 single core cable

PRODUCT REAL SHOT

 

1.0 mm² V-90 building wire
1.0mm² PVC insulated single core cable
1.0 sq mm copper building wire

1.0mm2 conduit wire

Compact Class 1 Conductor for Fixed Wiring and Enclosures
1.0mm2 solid copper wire is designed for neat, stable routing in protected fixed-wiring circuits, electrical enclosures, control devices and compact equipment where a Class 1 conductor is specified. The plain annealed copper conductor is manufactured to AS/NZS 1125, while the V90 PVC insulated wire provides single-core insulation without an outer sheath. Rated 0.6/1kV, this AS/NZS 5000.1 cable has a maximum continuous operating temperature of 75°C. GERITEL WIRE can support red, black, white, blue or green/yellow identification, project lengths, cable printing and coil packing. Final circuit selection should be confirmed against current, voltage drop, conduit fill and termination requirements.
PRODUCT SPECIFICATIONS

 

1.0mm2 copper conduit wire

Applications

 

For seperate earth conductors. For switchboard and control panel wiring. For fixed wiring within other enclosures or apparatus where the cable is not accessible without the use of tools. For use where improved aging properties to those of 75°C PVC are required because of higher ambient temperatures. Suitable for glanding

SPECIFICATIONS
CONDUCTOR

Plain annealed copper conductor to AS/NZS 1125
Maximum continuous operating temperature: 75°C

Can also be operated at temperatures up to 90°C when not exposed to mechanical deformation (see AS/NZS 3008.1)

INSULATION V-90 PVC
Colours: Red, Black, White, Blue, Green/Yellow

Conductor

Cable

Min.

installed

bending

radius

mm

Nominal

C.S.A

mm²

Nominal

diameter

of wires
No/mm

Nominal

diameter

mm

Nominal

insulation

thickness

mm

Overall diameter

Approx.

mass

kg/100 m

Minimum

mm

Maximum

mm

1.0* 1/11.3 1.13 0.8 2.6 2.8 1.7 10
1.5 7/0.50 1.5 0.8 3.0 3.2 2.2 15
2.5* 1/1.78 1.78 0.8 3.3 3.5 3.3 15
2.5 7/0.67 2.0 0.8 3.5 3.7 3.4 15
4 7/0.85 2.6 1.0 4.5 4.6 5.4 20
6 7/1.04 3.1 1.0 5.1 5.2 7.6 20
10 7/1.35 4.1 1.0 6.0 6.1 12 25
16 7/1.70 5.1 1.0 7.1 7.2 18 30
25 19/1.35 6.8 1.2 9.1 9.3 27 35
35 19/1.53 7.7 1.2 10.0 10.1 36 40
50 19/1.78 8.9 1.4 11.6 11.9 51 50
70 19/2.14 10.7 1.4 13.4 13.5 70 55
95 19/1.45 12.5 1.6 15.9 15.9 98 65
120 37/2.03 14.2 1.6 17.4 17.4 120 70
150 37/2.25 15.8 1.8 19.5 19.5 148 80
185 37/2.52 17.6 2.0 21.7 21.7 185 90

Conductor

nominal

C.S.A.

mm²

Current rating (a) Electrical characteristics
Three phase Single phase

Maximum D.C.

resistance

at20°C

Ω/km

Reactance per core

(Trefoil, Touching)

Ω/km

In conduit

in air A

Underground

in duct A

In conduitinair A

Underground

in duct A

1.0* 11 16 13 18 18.1 0.119
1.5 14 20 16 24 13.6 0.111
2.5* 20 28 22 33 7.41 0.102
2.5 20 28 22 33 7.41 0.102
4 26 37 30 42 4.61 0.102
6 34 46 38 53 3.08 0.0967
10 47 61 53 71 1.83 0.0906
16 62 80 71 91 1.15 0.0861
25 87 105 97 120 0.727 0.0853
35 100 125 115 145 0.524

0.0826

50 125 150 140 170 0.387 0.0797
70 155 185 175 210 0.268 0.0770
95 185 225 210 260 0.193 0.0766
120 220 260 250 295 0.153 0.0743
150 250 290 280 335 0.124 0.0745
185 285 335 325 380 0.0991 0.0744
CERTIFICATIONS

 

1.0mm2 0.6/1kV building wire

1.0mm2 600/1000V single core wire

PACKAGING

 

1.0mm2 AS/NZS 5000.1 cable

Roll

1.0mm2 AS/NZS 1125 copper wire

Plastic Reel

1C x 1.0mm2 V90 PVC cable

Small Wooden Reel

APPLICATION

 

1 x 1.0 mm² building wire
Industrial Control Panel
1.0mm2 unsheathed copper cable
Renewable Energy Power Connection
1.0mm2 fixed wiring cable

Switchboard Wiring

 

CASE

 

1.0mm2 switchboard wiring cable

Adelaide Airport Switchboard Upgrade

1.0mm2 control panel wiring cable

Industrial Main Switchboard Power Distribution

1.0mm2 building wire supplier

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

1.0mm2 building wire manufacturer
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

1.0mm2 V90 copper wire price
 
1.0mm2 V90 cable datasheet
 
V90 single core cable
 
V-90 single core cable
 
single core V90 cable
 
V90 PVC cable
 
GLOBAL CERTIFICATIONS

 

V-90 PVC insulated cable

CUSTOMER PHOTOS
 

PVC insulated single core cable

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

single core PVC insulated cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

PVC insulated copper wire
single core copper building wire
single core building wire
copper building wire
electrical building wire
V90 building wire
V-90 building wire
PVC building wire
copper conduit wire
conduit wire
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

single core conduit wire
FAQ

 

What is V-90 single core cable used for?
V-90 single core cable is an unsheathed, PVC-insulated copper building wire for protected fixed wiring such as conduit systems, switchboards, control panels, enclosures and separate earth conductors. GERITEL WIRE can help buyers match the conductor size, colour, length and packing to the project schedule before production.
What does V90 mean on an electrical cable?
V90 PVC insulation identifies the PVC insulation grade used on the cable. For this GERITEL WIRE product, use 75°C as the maximum continuous operating temperature and confirm any higher-temperature condition against the approved project datasheet and local wiring rules rather than relying on the name alone.
Is this product also called building wire or conduit wire?
Yes. Overseas buyers commonly search for single core building wire, conduit wire, CU conduit wire, 1C PVC V-90 and PVC insulated single core cable. GERITEL WIRE keeps the formal AS/NZS description in quotations while also using familiar market names so purchasing teams can cross-reference the correct construction.
Can you make the conductor tinned?
This is unsheathed building wire with V-90 PVC insulation only; it does not have a separate outer jacket. It should therefore be installed in a protected wiring method suitable for the location. GERITEL WIRE clearly states the insulation-only construction on datasheets, labels and quotations to prevent confusion with SDI or multicore sheathed cable.

 

Hot Tags: 1.0mm2 solid copper v90 building wire 0.6/1kv as/nzs 5000.1, China 1.0mm2 solid copper v90 building wire 0.6/1kv as/nzs 5000.1 manufacturers, suppliers, factory, 0 6 1KV Single Core Building Cable, 0 6 1KV Single Core Flexible Cable, single core building cable

Send Inquiry