185mm2 AS/NZS Single Core Copper Cable 0.6/1kV

185mm2 AS/NZS Single Core Copper Cable 0.6/1kV
Details:
·Insulation:V-90 PVC
·Plain annealed copper conductor to AS/NZS 1125
·Maximum continuous operating temperature:75℃
·PVC INSULATED ONLY CABLE TO AS/NZS 5000.1
·Colours: Red,Black,White,Blue,Green/Yellow
Send Inquiry
Download
Description
Technical Parameters
Certification

185mm2 V90 single core cable

PRODUCT REAL SHOT

 

185 mm² V-90 building wire
185mm² PVC insulated single core cable
185 sq mm copper building wire

185mm2 conduit wire

Plain Copper Building Wire for High-Capacity Fixed Installations
185mm2 V90 copper cable uses a 37/2.52 mm plain annealed copper conductor for large fixed-wiring duties, supporting protected connections in major switchboards, industrial distribution assemblies, plant enclosures and electrical apparatus. The 600/1000V single insulated wire is manufactured to AS/NZS 5000.1 with conductor construction to AS/NZS 1125. As a large size switchboard conductor, it has V-90 PVC insulation only, no outer sheath and a 75°C maximum continuous operating temperature. GERITEL WIRE can support colour identification, marking, cut lengths and drum packing. Final engineering must confirm current, fault level, voltage drop, grouping, support, bend space and terminal compatibility.
PRODUCT SPECIFICATIONS

 

185mm2 copper conduit wire

Applications

 

For seperate earth conductors. For switchboard and control panel wiring. For fixed wiring within other enclosures or apparatus where the cable is not accessible without the use of tools. For use where improved aging properties to those of 75°C PVC are required because of higher ambient temperatures. Suitable for glanding

SPECIFICATIONS
CONDUCTOR

Plain annealed copper conductor to AS/NZS 1125
Maximum continuous operating temperature: 75°C

Can also be operated at temperatures up to 90°C when not exposed to mechanical deformation (see AS/NZS 3008.1)

INSULATION V-90 PVC
Colours: Red, Black, White, Blue, Green/Yellow

Conductor

Cable

Min.

installed

bending

radius

mm

Nominal

C.S.A

mm²

Nominal

diameter

of wires
No/mm

Nominal

diameter

mm

Nominal

insulation

thickness

mm

Overall diameter

Approx.

mass

kg/100 m

Minimum

mm

Maximum

mm

1.0* 1/11.3 1.13 0.8 2.6 2.8 1.7 10
1.5 7/0.50 1.5 0.8 3.0 3.2 2.2 15
2.5* 1/1.78 1.78 0.8 3.3 3.5 3.3 15
2.5 7/0.67 2.0 0.8 3.5 3.7 3.4 15
4 7/0.85 2.6 1.0 4.5 4.6 5.4 20
6 7/1.04 3.1 1.0 5.1 5.2 7.6 20
10 7/1.35 4.1 1.0 6.0 6.1 12 25
16 7/1.70 5.1 1.0 7.1 7.2 18 30
25 19/1.35 6.8 1.2 9.1 9.3 27 35
35 19/1.53 7.7 1.2 10.0 10.1 36 40
50 19/1.78 8.9 1.4 11.6 11.9 51 50
70 19/2.14 10.7 1.4 13.4 13.5 70 55
95 19/1.45 12.5 1.6 15.9 15.9 98 65
120 37/2.03 14.2 1.6 17.4 17.4 120 70
150 37/2.25 15.8 1.8 19.5 19.5 148 80
185 37/2.52 17.6 2.0 21.7 21.7 185 90

Conductor

nominal

C.S.A.

mm²

Current rating (a) Electrical characteristics
Three phase Single phase

Maximum D.C.

resistance

at20°C

Ω/km

Reactance per core

(Trefoil, Touching)

Ω/km

In conduit

in air A

Underground

in duct A

In conduitinair A

Underground

in duct A

1.0* 11 16 13 18 18.1 0.119
1.5 14 20 16 24 13.6 0.111
2.5* 20 28 22 33 7.41 0.102
2.5 20 28 22 33 7.41 0.102
4 26 37 30 42 4.61 0.102
6 34 46 38 53 3.08 0.0967
10 47 61 53 71 1.83 0.0906
16 62 80 71 91 1.15 0.0861
25 87 105 97 120 0.727 0.0853
35 100 125 115 145 0.524

0.0826

50 125 150 140 170 0.387 0.0797
70 155 185 175 210 0.268 0.0770
95 185 225 210 260 0.193 0.0766
120 220 260 250 295 0.153 0.0743
150 250 290 280 335 0.124 0.0745
185 285 335 325 380 0.0991 0.0744
CERTIFICATIONS

 

185mm2 0.6/1kV building wire

185mm2 600/1000V single core wire

PACKAGING

 

185mm2 AS/NZS 5000.1 cable

Roll

185mm2 AS/NZS 1125 copper wire

Plastic Reel

1C x 185mm2 V90 PVC cable

Small Wooden Reel

APPLICATION

 

1 x 185 mm² building wire
Industrial Control Panel
185mm2 unsheathed copper cable
Renewable Energy Power Connection
185mm2 fixed wiring cable

Switchboard Wiring

 

CASE

 

185mm2 switchboard wiring cable

Adelaide Airport Switchboard Upgrade

185mm2 control panel wiring cable

Industrial Main Switchboard Power Distribution

185mm2 building wire supplier

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

185mm2 building wire manufacturer
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

185mm2 V90 copper wire price
 
185mm2 V90 cable datasheet
 
V90 wire wooden drum packing
 
V90 wire coil packing
 
private label building wire
 
custom printing single core cable
 
GLOBAL CERTIFICATIONS

 

custom length conduit wire

CUSTOMER PHOTOS
 

plain copper building wire factory direct

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

China V90 building wire manufacturer
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

Australian standard cable manufacturer China
V90 cable for Australia market
V90 cable for New Zealand market
what is V90 single core cable
what is V90 building wire
what is conduit wire used for
what does V90 PVC insulation mean
what is AS/NZS 5000.1 cable
what is AS/NZS 1125 conductor
V90 vs V75 building wire
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

V90 cable vs V90HT cable
FAQ

 

What do red, black, white and blue cable colours mean?
Electrical wire colour identification varies by system, project and current local rules, so colours should not be assigned from a generic online chart. GERITEL WIRE manufactures the buyer-approved colour schedule and can add package labels or printing that links each colour to the project item number.
Can I order a non-standard insulation colour?
Custom colour building wire may be possible when the required colour, quantity and compliance impact are reviewed before production. GERITEL WIRE can evaluate colour matching and minimum batch requirements, but safety colours and mandatory identification rules must not be overridden by branding preferences.
How do you keep insulation colour consistent between batches?
V90 cable colour consistency is controlled through approved material references and production checks, but slight visual differences can occur between manufacturing batches. GERITEL WIRE can retain an approved colour sample or agreed reference and recommends ordering project-critical quantities together where appearance must be closely matched.
Can the cable be printed with voltage, standard and size?
Custom cable printing can include agreed product type, voltage, size, standard reference, meter marking or buyer identification where permitted by the approved specification. GERITEL WIRE confirms the print legend before production and can provide a pre-production photo or sample for review on custom orders.

 

Hot Tags: 185mm2 as/nzs single core copper cable 0.6/1kv, China 185mm2 as/nzs single core copper cable 0.6/1kv manufacturers, suppliers, factory

Send Inquiry