35mm2 600/1000V Single Core Building Wire V-90 PVC

35mm2 600/1000V Single Core Building Wire V-90 PVC
Details:
·Insulation:V-90 PVC
·Plain annealed copper conductor to AS/NZS 1125
·Maximum continuous operating temperature:75℃
·PVC INSULATED ONLY CABLE TO AS/NZS 5000.1
·Colours: Red,Black,White,Blue,Green/Yellow
Send Inquiry
Download
Description
Technical Parameters
Certification

35mm2 V90 single core cable

PRODUCT REAL SHOT

 

35 mm² V-90 building wire
35mm² PVC insulated single core cable
35 sq mm copper building wire

35mm2 conduit wire

Unsheathed Copper Cable for Switchgear and Enclosed Wiring
35mm2 V90 copper wire uses a 19/1.53 mm stranded plain annealed copper conductor for fixed-wiring duties in switchgear, distribution assemblies, control cabinets and protected conduit systems. The AS/NZS building cable is PVC insulated only, rated 0.6/1kV and manufactured to AS/NZS 5000.1, with conductor requirements aligned to AS/NZS 1125. As a fixed installation conduit wire, it requires a wiring method that provides suitable mechanical protection and is specified for 75°C maximum continuous operation. GERITEL WIRE can support red, black, white, blue or green/yellow production, project marking, measured lengths and reel or drum packing. Installation must verify current, fault duty, grouping, bend space and termination suitability.
PRODUCT SPECIFICATIONS

 

35mm2 copper conduit wire

Applications

 

For seperate earth conductors. For switchboard and control panel wiring. For fixed wiring within other enclosures or apparatus where the cable is not accessible without the use of tools. For use where improved aging properties to those of 75°C PVC are required because of higher ambient temperatures. Suitable for glanding

SPECIFICATIONS
CONDUCTOR

Plain annealed copper conductor to AS/NZS 1125
Maximum continuous operating temperature: 75°C

Can also be operated at temperatures up to 90°C when not exposed to mechanical deformation (see AS/NZS 3008.1)

INSULATION V-90 PVC
Colours: Red, Black, White, Blue, Green/Yellow

Conductor

Cable

Min.

installed

bending

radius

mm

Nominal

C.S.A

mm²

Nominal

diameter

of wires
No/mm

Nominal

diameter

mm

Nominal

insulation

thickness

mm

Overall diameter

Approx.

mass

kg/100 m

Minimum

mm

Maximum

mm

1.0* 1/11.3 1.13 0.8 2.6 2.8 1.7 10
1.5 7/0.50 1.5 0.8 3.0 3.2 2.2 15
2.5* 1/1.78 1.78 0.8 3.3 3.5 3.3 15
2.5 7/0.67 2.0 0.8 3.5 3.7 3.4 15
4 7/0.85 2.6 1.0 4.5 4.6 5.4 20
6 7/1.04 3.1 1.0 5.1 5.2 7.6 20
10 7/1.35 4.1 1.0 6.0 6.1 12 25
16 7/1.70 5.1 1.0 7.1 7.2 18 30
25 19/1.35 6.8 1.2 9.1 9.3 27 35
35 19/1.53 7.7 1.2 10.0 10.1 36 40
50 19/1.78 8.9 1.4 11.6 11.9 51 50
70 19/2.14 10.7 1.4 13.4 13.5 70 55
95 19/1.45 12.5 1.6 15.9 15.9 98 65
120 37/2.03 14.2 1.6 17.4 17.4 120 70
150 37/2.25 15.8 1.8 19.5 19.5 148 80
185 37/2.52 17.6 2.0 21.7 21.7 185 90

Conductor

nominal

C.S.A.

mm²

Current rating (a) Electrical characteristics
Three phase Single phase

Maximum D.C.

resistance

at20°C

Ω/km

Reactance per core

(Trefoil, Touching)

Ω/km

In conduit

in air A

Underground

in duct A

In conduitinair A

Underground

in duct A

1.0* 11 16 13 18 18.1 0.119
1.5 14 20 16 24 13.6 0.111
2.5* 20 28 22 33 7.41 0.102
2.5 20 28 22 33 7.41 0.102
4 26 37 30 42 4.61 0.102
6 34 46 38 53 3.08 0.0967
10 47 61 53 71 1.83 0.0906
16 62 80 71 91 1.15 0.0861
25 87 105 97 120 0.727 0.0853
35 100 125 115 145 0.524

0.0826

50 125 150 140 170 0.387 0.0797
70 155 185 175 210 0.268 0.0770
95 185 225 210 260 0.193 0.0766
120 220 260 250 295 0.153 0.0743
150 250 290 280 335 0.124 0.0745
185 285 335 325 380 0.0991 0.0744
CERTIFICATIONS

 

35mm2 0.6/1kV building wire

35mm2 600/1000V single core wire

PACKAGING

 

35mm2 AS/NZS 5000.1 cable

Roll

35mm2 AS/NZS 1125 copper wire

Plastic Reel

1C x 35mm2 V90 PVC cable

Small Wooden Reel

APPLICATION

 

1 x 35 mm² building wire
Industrial Control Panel
35mm2 unsheathed copper cable
Renewable Energy Power Connection
35mm2 fixed wiring cable

Switchboard Wiring

 

CASE

 

35mm2 switchboard wiring cable

Adelaide Airport Switchboard Upgrade

35mm2 control panel wiring cable

Industrial Main Switchboard Power Distribution

35mm2 building wire supplier

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

35mm2 building wire manufacturer
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

35mm2 V90 copper wire price
 
35mm2 V90 cable datasheet
 
V90 building wire for fixed wiring in enclosures
 
V90 building wire for wiring inside apparatus
 
V90 building wire for cable gland terminations
 
V90 building wire for higher ambient temperature installations
 
GLOBAL CERTIFICATIONS

 

V90 building wire for plant room wiring

CUSTOMER PHOTOS
 

V90 building wire for factory electrical panels

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

V90 building wire for motor control centres
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

V90 building wire for switchgear panels
single core PVC cable for plastic conduit installations
single core PVC cable for metal conduit installations
single core PVC cable for switchboard wiring
single core PVC cable for control panel wiring
single core PVC cable for distribution board wiring
single core PVC cable for electrical cabinet wiring
single core PVC cable for machine internal wiring
single core PVC cable for industrial equipment wiring
single core PVC cable for commercial building wiring
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

single core PVC cable for domestic electrical installations
FAQ

 

How does voltage drop affect cable size?
Single core cable voltage drop increases with current and route length, so long circuits may need a larger conductor than thermal capacity alone suggests. GERITEL WIRE can supply sizes up to 185mm² and provide conductor details for calculation, while the project engineer confirms the permitted voltage-drop limit.
Should I increase the cable size for a long run?
A long run copper cable is often upsized to control voltage drop, but larger conductors also affect conduit size, bending space, lugs and cost. GERITEL WIRE can quote several size options and provide dimensions so the buyer can compare total installed practicality rather than selecting only by price per metre.
Can you provide an amp rating chart for every size?
A building wire amp rating chart is only useful when the installation assumptions are stated. GERITEL WIRE can include product dimensions and conductor construction, but will not present a single universal amp value that ignores conduit, grouping, ambient temperature or thermal insulation. Use the current local design standard for approval.
What cable derating factors should be considered?
V90 cable derating may be required for high ambient temperature, grouped circuits, thermal insulation, conduit conditions and other heat restrictions. GERITEL WIRE can maintain the specified material and dimensions, while the designer applies the correct factors to the actual route before confirming conductor size.

 

Hot Tags: 35mm2 600/1000v single core building wire v-90 pvc, China 35mm2 600/1000v single core building wire v-90 pvc manufacturers, suppliers, factory, 0 6 1KV Single Core Building Cable, 0 6 1KV Single Core Flexible Cable, single core building cable

Send Inquiry