AC90 Armoured Cable For Electrical Rooms Copper 600V Building Wire

AC90 Armoured Cable For Electrical Rooms Copper 600V Building Wire
Details:
·Conductor: Solid Soft Copper, ASTM B3
·Insulation: Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
·Colour Code: Black, White
·Bonding Conductor: Solid ASTM B3 Soft Bare Copper
·Armour: Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
·Voltage Rating: 600V
Send Inquiry
Download
Description
Technical Parameters
Certification

AC90 2 conductor cable for sale

PRODUCT REAL SHOT

 

AC90 cable for retail lighting wiring
AC90 wire for retail lighting wiring
AC90 cable for warehouse lighting wiring

AC90 wire for warehouse lighting wiring

Durable interior wiring for panel areas and distribution spaces
Electrical rooms and distribution spaces often require wiring that can tolerate frequent installation activity while remaining easy to route. AC90 armoured cable protects its copper conductors with RW90 insulation and flexible interlocked aluminum armour, making it suitable for many 600V dry-location building applications. The 2 conductor black/white construction can be used for selected branch circuits and equipment feeds where AC90 is permitted. GERITEL WIRE supports buyers sourcing AC90 cable for electrical rooms with project quantities, traceable production batches, custom markings, reel or coil packaging and scheduled delivery, serving contractors, switchgear installers, building owners and electrical wholesalers.
PRODUCT SPECIFICATIONS

 

AC90 cable for emergency lighting branch wiring

APPLICATIONS

 

Manufactured, tested and certified in Canada, GERITEL WIRE AC90 armoured building wire is rated FT4-ST1 for -40°C to 90°C. Engineered specifically for demanding environments, superior flammability and smoke emission performance.

For use in ventilated, non-ventilated and ladder-type cable trays.

For dry locations, in ceiling air-handling plenums, exposed or concealed wiring and service entrance above ground.

SPECIFICATIONS
Conductor Solid Soft Copper, ASTM B3
Insulation Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
Colour Code Black, White
Bonding Conductor Solid ASTM B3 Soft Bare Copper
Armour Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
Specifications and Compliance

CSA C22.2 No. 51, Armoured Cables (Type AC90)

CSA C22.2 No. 38 Thermoset-insulated wires and cables (Type RW90)

CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test

IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated

-40°C Cold Bend and -40°C Cold Impact

Limited Smoke and Halogen Free

AC90 & ISO-AC90 600V CSA FT4-ST1 LSZH

 

AC90

Power

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
Count AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 0.030 0.76 0.430 10.9 81 120 66 30 6.0 151 25
2 12 14 0.030 0.76 0.454 11.5 99 148 104 47 6.4 164 30
2 10 12 0.030 0.76 0.512 13.0 138 206 166 75 6.9 174 40
3 14 14 0.030 0.76 0.445 11.3 105 156 99 45 6.2 158 25
3 12 14 0.030 0.76 0.490 12.4 130 193 157 71 6.9 174 30
3 10 12 0.030 0.76 0.535 13.6 182 271 249 113 7.5 190 40
3 8/7 10 0.045 1.14 0.714 18.1 309 460 418 190 10.0 254 55
3 6/7 8/7 0.045 1.14 0.770 19.6 417 621 702 318 10.8 274 75
3 4/7 8/7 0.045 1.14 0.940 23.9 601 894 1193 541 13.2 334 95
3 3/7 6/7 0.045 1.14 0.990 25.1 721 1073 1622 736 13.9 352 115
3 2/7 6/7 0.045 1.14 1.040 26.4 891 1326 1922 872 14.6 370 130
4 14 14 0.030 0.76 0.490 12.4 130 193 131 60 6.9 174 20
4 12 14 0.030 0.76 0.535 13.6 166 247 209 95 7.5 190 24
4 10 12 0.030 0.76 0.630 16.0 232 345 332 150 8.8 224 32

 

ISO-AC90

Conductor

Count

Power

Conductor

Ins.Ground

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
AWG AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 14 0.030 0.76 0.440 11.2 105 156 66 30 6.2 157 25
2 12 12 14 0.030 0.76 0.485 12.3 138 206 104 47 6.8 173 30
2 10 10 12 0.030 0.76 0.533 13.5 186 277 166 75 7.5 190 40
3 12 12 14 0.030 0.76 0.535 13.6 165 245 157 71 7.5 190 24
3 10 10 12 0.030 0.76 0.591 15.0 232 346 249 113 8.3 210 32
CERTIFICATIONS

 

AC90 wire for emergency lighting branch wiring

PACKAGING

 

AC90 cable for general purpose receptacle wiring

Roll

AC90 wire for general purpose receptacle wiring

Plastic Reel

AC90 cable for office receptacle wiring

Small Wooden Reel

APPLICATION

 

AC90 wire for office receptacle wiring
Apartment/Residential Building Electrical Distribution
AC90 cable for commercial receptacle wiring
Commercial Building Electrical Distribution
AC90 wire for commercial receptacle wiring
Industrial Factory Power Distribution
CASE

 

AC90 cable for apartment receptacle wiring

Calgary Alberta Multi Storey Apartment Construction Upgrade

AC90 wire for apartment receptacle wiring

Toronto Ontario Detached House Basement Panel Upgrade

AC90 cable for equipment receptacle wiring

Vancouver British Columbia Downtown Office Renovation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

AC90 wire for equipment receptacle wiring
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

AC90 cable for indoor dry location wiring
 
AC90 wire for indoor dry location wiring
 
AC90 cable for dry building wiring
 
AC90 wire for dry building wiring
 
AC90 cable for protected interior wiring
 
AC90 wire for protected interior wiring
 
GLOBAL CERTIFICATIONS

 

AC90 cable for indoor armoured branch circuits

CUSTOMER PHOTOS
 

AC90 wire for indoor armoured branch circuits

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

AC90 cable for indoor armoured feeder wiring
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

AC90 wire for indoor armoured feeder wiring
AC90 cable for interior mechanical protection wiring
AC90 wire for interior mechanical protection wiring
AC90 cable for low smoke building wiring
AC90 wire for low smoke building wiring
AC90 cable for zero halogen building cable applications
AC90 wire for zero halogen building cable applications
AC90 cable for FT4 commercial building wiring
AC90 wire for FT4 commercial building wiring
AC90 cable for ST1 building wiring
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

AC90 wire for ST1 building wiring
FAQ

 

Can AC90 be used in renovation projects?
Yes. AC90 cable for renovation is often useful in renovations because its flexible armoured construction can simplify routing through existing building spaces. Installers still need to verify available pathways, code compliance and environmental conditions.
Can AC90 be used in modular or prefabricated buildings?
Yes, AC90 cable for modular buildings can be used in modular or prefabricated construction where the listed assembly, project design and local code permit AC90-type wiring. It is especially useful for repeatable dry-location branch-circuit layouts.
Can AC90 be used in data centers?
Standard AC90 cable for data center wiring can be used for general dry-location building circuits such as lighting, receptacles and support-space power where allowed. For isolated-ground electronic equipment circuits, ISO-AC90 is the more specific product and should be evaluated separately.
Can AC90 be used in server rooms?
Yes, AC90 cable for server room wiring can serve general building-power circuits in dry server-room environments when allowed by the design. Sensitive electronic circuits that require an isolated grounding arrangement may call for ISO-AC90 instead.

 

Hot Tags: ac90 armoured cable for electrical rooms copper 600v building wire, China ac90 armoured cable for electrical rooms copper 600v building wire manufacturers, suppliers, factory, ac cable, AC Power Cable

Send Inquiry