AC90 Copper Cable For Mechanical Room Wiring 2 Conductor 600V

AC90 Copper Cable For Mechanical Room Wiring 2 Conductor 600V
Details:
·Conductor: Solid Soft Copper, ASTM B3
·Insulation: Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
·Colour Code: Black, White
·Bonding Conductor: Solid ASTM B3 Soft Bare Copper
·Armour: Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
·Voltage Rating: 600V
Send Inquiry
Download
Description
Technical Parameters
Certification

AC90 cable for low carbon building wiring

PRODUCT REAL SHOT

 

AC90 wire for low carbon building wiring
AC90 cable for green building electrical wiring
AC90 wire for green building electrical wiring

AC90 cable for LEED project building wiring

Flexible armoured wiring for protected indoor equipment areas
Mechanical rooms contain equipment, framing and service routes that can make cable installation challenging. AC90 cable for mechanical rooms provides a flexible armoured solution using copper conductors, RW90 XLPE insulation and interlocked aluminum armour for dry indoor building wiring. The black/white 2 conductor arrangement is suitable for many branch circuits supplying lighting, receptacles and auxiliary loads around mechanical service areas. Contractors and distributors choosing copper AC90 cable can source from GERITEL WIRE with customized printing, project packing, order consolidation and repeat production support, helping keep material consistent across commercial, residential and institutional construction programs.
PRODUCT SPECIFICATIONS

 

AC90 wire for LEED project building wiring

APPLICATIONS

 

Manufactured, tested and certified in Canada, GERITEL WIRE AC90 armoured building wire is rated FT4-ST1 for -40°C to 90°C. Engineered specifically for demanding environments, superior flammability and smoke emission performance.

For use in ventilated, non-ventilated and ladder-type cable trays.

For dry locations, in ceiling air-handling plenums, exposed or concealed wiring and service entrance above ground.

SPECIFICATIONS
Conductor Solid Soft Copper, ASTM B3
Insulation Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
Colour Code Black, White
Bonding Conductor Solid ASTM B3 Soft Bare Copper
Armour Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
Specifications and Compliance

CSA C22.2 No. 51, Armoured Cables (Type AC90)

CSA C22.2 No. 38 Thermoset-insulated wires and cables (Type RW90)

CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test

IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated

-40°C Cold Bend and -40°C Cold Impact

Limited Smoke and Halogen Free

AC90 & ISO-AC90 600V CSA FT4-ST1 LSZH

 

AC90

Power

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
Count AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 0.030 0.76 0.430 10.9 81 120 66 30 6.0 151 25
2 12 14 0.030 0.76 0.454 11.5 99 148 104 47 6.4 164 30
2 10 12 0.030 0.76 0.512 13.0 138 206 166 75 6.9 174 40
3 14 14 0.030 0.76 0.445 11.3 105 156 99 45 6.2 158 25
3 12 14 0.030 0.76 0.490 12.4 130 193 157 71 6.9 174 30
3 10 12 0.030 0.76 0.535 13.6 182 271 249 113 7.5 190 40
3 8/7 10 0.045 1.14 0.714 18.1 309 460 418 190 10.0 254 55
3 6/7 8/7 0.045 1.14 0.770 19.6 417 621 702 318 10.8 274 75
3 4/7 8/7 0.045 1.14 0.940 23.9 601 894 1193 541 13.2 334 95
3 3/7 6/7 0.045 1.14 0.990 25.1 721 1073 1622 736 13.9 352 115
3 2/7 6/7 0.045 1.14 1.040 26.4 891 1326 1922 872 14.6 370 130
4 14 14 0.030 0.76 0.490 12.4 130 193 131 60 6.9 174 20
4 12 14 0.030 0.76 0.535 13.6 166 247 209 95 7.5 190 24
4 10 12 0.030 0.76 0.630 16.0 232 345 332 150 8.8 224 32

 

ISO-AC90

Conductor

Count

Power

Conductor

Ins.Ground

Conductor

Ground

Conductor

Insulation

Thickness

Armour

O.D

Cable

Weight

Max Pulling

Tension

Min Bend Radius Ampacity
AWG AWG AWG in mm in mm lbs/Mft kg/km lbs kg in mm A
2 14 14 14 0.030 0.76 0.440 11.2 105 156 66 30 6.2 157 25
2 12 12 14 0.030 0.76 0.485 12.3 138 206 104 47 6.8 173 30
2 10 10 12 0.030 0.76 0.533 13.5 186 277 166 75 7.5 190 40
3 12 12 14 0.030 0.76 0.535 13.6 165 245 157 71 7.5 190 24
3 10 10 12 0.030 0.76 0.591 15.0 232 346 249 113 8.3 210 32
CERTIFICATIONS

 

AC90 cable for airport terminal interior wiring

PACKAGING

 

AC90 wire for airport terminal interior wiring

Roll

copper conductor AC90 cable

Plastic Reel

copper conductor AC90 wire

Small Wooden Reel

APPLICATION

 

solid copper AC90 cable
Apartment/Residential Building Electrical Distribution
solid copper AC90 wire
Commercial Building Electrical Distribution
stranded copper AC90 cable
Industrial Factory Power Distribution
CASE

 

stranded copper AC90 wire

Calgary Alberta Multi Storey Apartment Construction Upgrade

annealed copper AC90 cable

Toronto Ontario Detached House Basement Panel Upgrade

annealed copper AC90 wire

Vancouver British Columbia Downtown Office Renovation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

bare copper bonding conductor AC90 cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

bare copper bonding conductor AC90 wire
 
copper bonding wire AC90 cable
 
copper bonding wire AC90 wire
 
XLPE insulated AC90 cable
 
XLPE insulated AC90 wire
 
RW90 insulated AC90 cable
 
GLOBAL CERTIFICATIONS

 

RW90 insulated AC90 wire

CUSTOMER PHOTOS
 

cross linked polyethylene AC90 cable

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

cross linked polyethylene AC90 wire
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

cross-linked polyethylene AC90 cable
cross-linked polyethylene AC90 wire
paper wrapped AC90 cable
paper wrapped AC90 wire
paper binder AC90 cable
paper binder AC90 wire
paper wrapped armoured cable AC90 cable
paper wrapped armoured cable AC90 wire
aluminum interlocked armour AC90 cable
aluminum interlocked armour AC90 wire
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

aluminium interlocked armour AC90 cable
FAQ

 

Can AC90 be used inside electrical cabinets?
A AC90 cable for electrical panels may terminate at panelboards, distribution equipment or cabinets, but AC90 is generally a building-wiring cable rather than internal control-panel hook-up wire. Inside-cabinet conductors and wiring methods should follow the equipment standard and design.
Can AC90 cable be installed outdoors?
Standard AC90 dry location cable is generally intended for dry locations, so it should not be selected as a general outdoor cable simply because it has metal armour. For wet or outdoor exposure, consider a cable such as ACWU90 or another product specifically rated for the environment.
Can AC90 be installed in wet locations?
Standard AC90 dry location wire is not the preferred choice for wet-location installation. Even though the individual conductors may use RW90 insulation, the complete cable assembly should be used according to its certified location rating.
Can AC90 be direct buried?
Standard AC90 building cable should not be assumed suitable for direct burial. Direct-burial projects normally require a cable specifically certified for that environment, such as an appropriate ACWU90 or other underground-rated construction.

 

Hot Tags: ac90 copper cable for mechanical room wiring 2 conductor 600v, China ac90 copper cable for mechanical room wiring 2 conductor 600v manufacturers, suppliers, factory, ac cable, AC Power Cable

Send Inquiry