ACWU90 4 Conductor Cable For Wet Location Power Routing

ACWU90 4 Conductor Cable For Wet Location Power Routing
Details:
·Conductor: 8000 series compact-stranded aluminum alloy
·Insulation: XLPE. Thickness per CSA C22.2 No. 51
·Armor: Aluminum interlocked armour(AIA)
·Jacket: Flame retardant PVC jacket
·Voltage Rating: 600V
·Rated temperature: 90°C
·Flame test rating: FT4
·Low temperatue classification: -40°C
·Application: Commercial Building Power Distribution、Residential Building Electrical Feeders、Industrial Manufacturing Plants、Underground Power Distribution、Building Service Entrance Installations、Electrical Distribution Panels...
Send Inquiry
Download
Description
Technical Parameters
Certification

Dongguan Greater Wire & Cable Co., Ltd. is one of the leading manufacturers and suppliers of acwu90 4 conductor cable for wet location power routing in China, also supports customized service. Please rest assured to wholesale durable acwu90 4 conductor cable for wet location power routing made in China here from our factory. If you have any enquiry about free sample, please feel free to email us.

 

ACWU90 90 Degree Celsius Cable

PRODUCT REAL SHOT

 

ACWU90 90 Degree Celsius Wire

 

600V ACWU90 90 Degree Celsius Cable
ACWU90 Aluminum Armoured Cable 90 Degree Celsius

ACWU90 Cable with multiconductor design

Evaluate moisture exposure and installation conditions
Water exposure does not occur only underground. Equipment yards, outdoor risers and certain service spaces can also qualify as wet locations under the governing rules. ACWU90 4 Conductor Cable is commonly considered for appropriately approved wet-location feeder routes because its 600V construction uses XLPE-insulated aluminum conductors, interlocked aluminum armour and a protective PVC jacket. This is not permission to ignore sealing, fittings or the exact product listing. GERITEL WIRE helps electrical contractors assess documentation and order logistics, including planned delivery lots and reel protection. Tell us whether the run is continuously exposed, partly concealed or transitioning between installation methods so the enquiry can be reviewed accurately.
PRODUCT SPECIFICATIONS

 

ACWU90 Wire with multiconductor design

Scope

 

This specification covers three or four compact-stranded 8000 series aluminum alloy conductors with cross-linked polyethylene (XLPE) insulation plus one bare aluminum alloy bonding conductor in multi-conductor cables. Conductor assembly is wrapped and enclosed in interlocked aluminum armour with flame retardant PVC jacket.Type ACWU90 cable is conforming to CSA C22.2 No. 51 standard .cUL file No.E544860.

Application

 

Type ACWU90 cables are primarily intended for exposed and concealed wiring in dry or wet locations and where exposed to the weather. For use in ventilated, non-ventilated, and ladder type cable trays in wet and dry locations; direct earth burial; service entrance above or below ground.

SPECIFICATIONS
Conductor 8000 series compact-stranded aluminum alloy
Insulation XLPE. Thickness per CSA C22.2 No. 51
Color Coding

For 3 conductors construction: Black, red and blue plus bare bonding conductor.Or black, red and white plus bare bonding conductor.

For 4 conductors construction: Black, red, blue and white plus bare bonding conductor.

Bonding Conductor One bare 8000 series compact-stranded aluminum alloy.
Cabling

Three or four insulated conductors plus one bare bonding conductor are assembled without fillers and wrapped by a PP tape.

Armour Aluminum interlocked armour(AIA)
Jacket Flame retardant PVC jacket
Rated Voltage

600V 

Rated Temperature 90°C
Low Temperatue Classification -40°C
Flame Test Rating FT4

Type ACWU90 Cable Data

(AA 8000 series alloy conductor)

SIZE
(AWG/kcmil)

Strands

No./O.D.

(mm)

XLPE

Insulation

Average

Thickness

(mm)

PVC

Jacket

Average

Thickness

(mm)

Approx.

O.D.

(mm)

Max.DC

Resistance

(20°C,Ω/km)

Approx.

Weight

(kg/km)

3 x 6+8

7/1.60

7/1.28

0.76 1.14 21.44 2.211/3.515 469.49
3 x 4+6

7/2.02

7/1.60

1.02 1.14 24.84 1.390/2.211 630.58
3 x 2+6

7/2.58

7/1.60

1.02 1.14 30.68 0.8745/2.211 805.92
3 x 1+4

18/1.82

7/2.02

1.27 1.14 33.61 0.6934/1.390 980.49
3 x 1/0+4

18/2.02

7/2.02

1.27 1.14 35.51 0.5498/1.390 1112.91
3 x 2/0+4

18/2.32

7/2.02

1.27 1.14 37.24 0.4361/1.390 1267.50
3 x 3/0+4

18/2.58

7/2.02

1.27 1.14 39.32 0.3459/1.390 1459.66
3 x 4/0+4

18/2.83

7/2.02

1.27 1.14 41.86 0.2743/1.390 1699.24
3 x 250+2

36/2.22

7/2.58

1.52 1.14 45.65 0.2322/0.8745 2008.08
3 x 300+2

36/2.42

7/2.58

1.52 1.14 47.92 0.1935/0.8745 2268.74
3 x 350+2

36/2.58

7/2.58

1.52 1.14 51.11 0.1659/0.8745 2623.71
3 x 400+2

36/2.74

7/2.58

1.52 1.14 53.29 0.1450/0.8745 2894.90
3 x 500+2

36/3.10

18/1.82

1.52 1.14 57.01 0.1161/0.6934 3420.76
3 x 600+2

58/2.65

18/1.82

1.52 1.50 61.40 0.09673/0.6934 4038.83
3 x 750+1/0

58/2.98

18/2.02

1.52 1.50 66.21 0.07738/0.5498 4823.16
4 x 6+8

7/1.60

7/1.28

0.76 1.14 23.29 2.211/3.515 549.68
4 x 4+6

7/2.02

7/1.60

1.02 1.14 27.15 1.390/2.211 749.09
4 x 2+6

7/2.58

7/1.60

1.02 1.14 33.48 0.8745/2.211 970.96
4 x 1+4

18/1.82

7/2.02

1.27 1.14 36.78 0.6934/1.390 1186.84
4 x 1/0+4

18/2.02

7/2.02

1.27 1.14 39.05 0.5498/1.390 1358.96
4 x 2/0+4

18/2.32

7/2.02

1.27 1.14 41.10 0.4361/1.390 1561.06
4 x 3/0+4

18/2.58

7/2.02

1.27 1.14 43.59 0.3459/1.390 1812.41
4 x 4/0+4

18/2.83

7/2.02

1.27 1.14 46.61 0.2743/1.390 2125.94
4 x 250+2

36/2.22

7/2.58

1.52 1.14 51.96 0.2322/0.8745 2615.19
4 x 300+2

36/2.42

7/2.58

1.52 1.14 54.66 0.1935/0.8745 2963.18
4 x 350+2

36/2.58

7/2.58

1.52 1.14 57.15 0.1659/0.8745 3303.61
4 x 400+2

36/2.74

7/2.58

1.52 1.14 60.50 0.1450/0.8745 3763.51
4 x 500+2

36/3.10

18/1.82

1.52 1.50 64.79 0.1161/0.6934 4451.79
4 x 600+2

58/2.65

18/1.82

1.52 1.50 69.11 0.09673/0.6934 5133.01
4 x 750+1/0

58/2.98

18/2.02

1.52 1.50 74.65 0.07738/0.5498 6151.02
CERTIFICATIONS

 

4 Conductor ACWU90 Cable with multiconductor design

PACKAGING

 

ACWU90 Multiconductor Design Cable

Roll

ACWU90 Multiconductor Design Wire

Small Wooden Reel

600V ACWU90 Multiconductor Design Cable

Large Wooden Reel

APPLICATION

 

4 Conductor ACWU90 Cable with PVC jacketed armour
Battery Energy Storage System (BESS) AC Power Distribution
ACWU90 Jacketed Armour Cable
Commercial Building Power Distribution
ACWU90 Jacketed Armour Wire
Industrial Manufacturing Plant Power Distribution
CASE

 

600V ACWU90 Jacketed Armour Cable

Garden Bay Water Treatment Plant Generator Replacement

ACWU90 Aluminum Armoured Cable Jacketed Armour

Sechelt Aquatic Centre Lighting Upgrade

ACWU90 Cable with integral bonding conductor

Watson Lake Recreation Centre Change Room Renovation

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

ACWU90 Wire with integral bonding conductor
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

4 Conductor ACWU90 Cable with integral bonding conductor
 
ACWU90 Electrical Bonding Cable
 
ACWU90 Electrical Bonding Wire
 
600V ACWU90 Electrical Bonding Cable
 
ACWU90 Aluminum Armoured Cable Electrical Bonding
 
ACWU90 Cable with aluminum conductor construction
 
GLOBAL CERTIFICATIONS

 

ACWU90 Cable for CSA C22.2 No 51 cable standard

CUSTOMER PHOTOS
 

600V ACWU90 Power Wire for water treatment plants

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

ACWU90 Wire for CSA C22.2 No 51 cable standard
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

4 Conductor ACWU90 Cable for CSA C22.2 No 51 cable standard
600V ACWU90 Cable for CSA C22.2 No 51 cable standard
ACWU90 CSA Cable
ACWU90 CSA Wire
ACWU90 Canadian Code Cable
ACWU90 Wire for Canadian electrical code projects
4 Conductor ACWU90 Cable for Canadian electrical code projects
600V ACWU90 Cable for Canadian electrical code projects
ACWU90 4C Aluminum Cable
ACWU90 Canadian Code Wire
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

ACWU90 Cable for 600 volt rated feeders
FAQ

 

Where is 4C 1/0 ACWU90 four-conductor cable typically considered?
A project designer may assess ACWU90 1/0 AWG 4 conductor cable for four conductor building feeder schedules where a fixed 600V feeder and the four-insulated-conductor layout match the electrical drawings. Check XLPE insulation and terminal temperature, conductor ampacity under the governing code, fittings and certification before selecting the cable.
What details should buyers confirm before ordering 4C 1/0 ACWU90?
An RFQ for 4C 1/0 ACWU90 aluminum cable should list the 1/0 AWG conductor size, four insulated power cores, the required bonding arrangement, approved Canadian marking, reel lengths and site destination. GERITEL WIRE can then discuss China factory supply and documentation aligned with the final project specification.
Where is 4C 2/0 ACWU90 four-conductor cable typically considered?
A project designer may assess ACWU90 2/0 AWG 4 conductor cable for electrical panel incoming feeds where a fixed 600V feeder and the four-insulated-conductor layout match the electrical drawings. Check aluminum-rated lugs and cabinet entry, conductor ampacity under the governing code, fittings and certification before selecting the cable.
What details should buyers confirm before ordering 4C 2/0 ACWU90?
An RFQ for 4C 2/0 ACWU90 aluminum cable should list the 2/0 AWG conductor size, four insulated power cores, the required bonding arrangement, approved Canadian marking, reel lengths and site destination. GERITEL WIRE can then discuss China factory supply and documentation aligned with the final project specification.

 

Hot Tags: acwu90 4 conductor cable for wet location power routing, China acwu90 4 conductor cable for wet location power routing manufacturers, suppliers, factory

Send Inquiry