CSA ACWU90 Cable 4 conductor 600V AIA Flame Retardant

CSA ACWU90 Cable 4 conductor 600V AIA Flame Retardant
Details:
• Conductor: Bare ACM aluminum compact or compressed Class B strand
• Insulation: Cross-Linked Polyethylene (XLPE) Type RW90
• Ground (Bonding) Conductor: Stranded bare aluminum
• Armour: Aluminum Interlocked Armour (AIA)
• Outer Jacket: Flame-retardant (FR), moisture and sunlight resistant Polyvinyl Chloride (PVC), black
• Options: Other coloured outer jackets and constructions available upon request
• Specifications: CSA FT4; CSA C22.2 No.51 &174; IEEE 1202 & 383.UL 1581; ICEAT-30-520; OSHA Acceptable
Send Inquiry
Download
Description
Technical Parameters
Certification
4 core ACWU90 Cable

 

CSA ACWU90 Cable 4 conductor 600V AIA Flame Retardant
 

ACWU90 cable uses aluminum compact conductors to provide excellent conductivity and lightweight characteristics. Its insulation layer uses cross-linked polyethylene (XLPE), which meets the RW 90 standard, has excellent heat resistance and electrical aging resistance, and can work in wet or dry environments. The outer layer of the cable is equipped with aluminum interlocking armor (AIA), which effectively enhances mechanical strength and resistance to external damage, and is suitable for installation needs in harsh environments. The outer sheath is made of low-acid gas, flame-retardant, moisture-resistant and UV-resistant polyvinyl chloride (PVC), and is black, custom colors can be provided upon request.

 

Application

 

 

ACWU90 cable is suitable for exposed and concealed wiring in dry, damp, or wet environments. It can be used in ventilated, non-ventilated, and ladder-shaped cable trays in dry, damp, or wet environments. It is also suitable for direct buried installation (provided appropriate protection is required by the inspection agency). When used with certified HL cable glands, ACWU90 cable can be used for wiring in hazardous areas. The cable is also suitable for service entrance installation, providing reliable power transmission in a variety of environments.

ACWU90 Cable application

 

Certification

 

ACWU90 cable is CUL certified and complies with Canadian electrical standards. CUL certified ACWU cable indicates its reliability in wet environments and underground use, and is suitable for residential, commercial, and industrial fields, especially in applications requiring moisture and corrosion resistance. The cable uses aluminum conductors, is lightweight, and its temperature range can reach 90°C, which can provide stable power transmission under harsh conditions.

UL1569 ACWU90 cable

 

Package

 

ACWU90 cable package

 

Production Line

 

ACWU90 wire manufacturer

 

Greater Wire Manufacturer is a professional ACWU90 cable manufacturer with decades of industry expertise and a commitment to engineering excellence. Equipped with advanced production technology and precision-controlled manufacturing processes, we ensure every meter of cable meets stringent quality and safety standards. Our state-of-the-art facilities allow us to produce ACWU90 cables with consistent conductor compactness, insulation integrity, and armor alignment, delivering superior performance and durability in demanding applications. By integrating automated quality control systems and international certifications, we guarantee products that not only comply with CSA and other global standards but also exceed customer expectations in reliability and longevity.

 

customer

As a factory with more than 30 years of manufacturing experience, our customers are all over the world. We provide wires and cables to more than 90 countries and regions around the world and are familiar with the local standards of various countries.

wire and cable manufacturer

 

 

Partner

 

Greater Wire Partner

 

FAQ

 

 

 

 

Q: What does ACWU90 mean?

A: ACWU90 refers to a specific type of electrical cable, typically used in Canada.
AC: Stands for Aluminum Conductor, meaning the cable has an aluminum core.
W: Indicates the cable is suitable for wet locations, meaning it can be exposed to moisture or outdoor environments without damage.
U: Stands for Underground, implying the cable is rated for installation in the ground or buried directly.
90: Refers to the cable's temperature rating-in this case, the cable can operate at temperatures up to 90°C.

Q: Is ACWU always aluminum?

A: Yes, ACWU cables are typically aluminum conductor cables. The "A" in ACWU stands for Aluminum, indicating that the core conductor is made of aluminum. However, there are other similar cables with different conductor materials, such as ACSR (Aluminum Conductor Steel Reinforced) or AWG (American Wire Gauge), which can have copper or other materials. But for ACWU, aluminum is standard.

 

Q: What is the difference between Teck and ACWU?

A: ACWU cables with aluminum conductors are approximately half the weight of the equivalent copper conductor Teck cables. ACWU is commonly available in 600V ratings, whereas Teck cables are typically stocked in 600V, 1kV, or higher voltage ratings, providing more flexibility for higher voltage applications.

 

 

Hot Tags: CSA ACWU90 Cable 4 conductor 600V AIA Flame Retardant, China CSA ACWU90 Cable 4 conductor 600V AIA Flame Retardant manufacturers, suppliers, factory, H07ZZ F Cable, Super Flexible Welding Cable, CU XLPE SWA Cable, CU XLPE STA Cable, 300 300V 2 3 4 Core H03VV F Cable, SAA Orange Circular Cable

4 core ACWU90 Cables

 

NO OF
COND.
COND.
SIZE
(AWG/
kcmil)

GROUNDWIRE SIZE (AWG

/kcmil)

MIN. AVG.
INSULATION
THICKNESS
NOMINAL DIAMETER (OVER) NET
WEIGHT
AMPACITY
AT 9O° C
TWISTED CORE ARMOUR CABLE
INCHES mm INCHES mm INCHES mm INCHES mm KG/KM
3 8 8 0.045 1.14 0.533 13.5 0.783 19.89 0.870 22.10 422 45
3 6 8 0.045 1.14 0.565 14.4 0.845 21.46 0.932 23.67 498 55*
3 4 6 0.045 1.14 0.675 17.1 0.925 23.50 1.012 25.70 619 75
3 3 6 0.045 1.14 0.744 18.9

0.994

25.25 1.081 27.46 690 85
3 2 6 0.045 1.14 0.785 19.9 1.070 27.18 1.157 29.39 794 100
3 1 4 0.055 1.40 0.902 22.9 1.152 29.26 1.239 31.47 951 115
3 1/0 4 0.055 1.40 1.107 28.1 1.357 34.47 1.314 33.38 1085 135
3 2/0 4 0.055 1.40 1.066 27.1 1.316 33.43 1.403 35.64 1246 150
3 3/0 4 0.055 1.40 1.170 29.7 1.420 36.07 1.507 38.28 1450 175
3 4/0 4 0.055 1.40 1.281 32.5 1.531 38.89 1.636 41.55 1697 205
3 250 2 0.065 1.65 1.391 35.3 1.641 41.68 1.771 44.98 2072 230
3 300 2 0.065 1.65 1.496 38.0 1.836 46.63 1.966 49.94 2378 260
3 350 2 0.065 1.65 1.593 40.5 1.903 48.34 2.000 50.80 2681 280
3 400 2 0.065 1.65 1.686 42.8 1.996 50.70 2.101 53.37 2946 305
3 500 1 0.065 1.65 1.852 47.0 2.152 54.66 2.280 57.91 3585 350
3 600 1 0.080 2.03 2.077 52.8 2.267 57.58 2.518 63.96 4286 385
3 750 1/0 0.080 2.03 2.329 59.2 2.639 67.03 2.770 70.36 5058 435

 

NO OF
COND.
COND.
SIZE
(AWG/
kcmil)

GROUNDWIRE SIZE (AWG

/kcmil)

MIN. AVG.
INSULATION
THICKNESS
NOMINAL DIAMETER (OVER) NET
WEIGHT
AMPACITY
AT 9O° C
TWISTED CORE ARMOUR CABLE
INCHES mm INCHES mm INCHES mm INCHES mm KG/KM
4 8 8 0.045 1.14 0.620 15.7 0.812 20.62 0.899 22.83 451 45
4 6 8 0.045 1.14 0.636 16.2 0.886 22.50 0.973 24.71 569 55*
4 4 6 0.045 1.14 0.745 18.9 0.995 25.27 1.095 27.81 748 75
4 3 6 0.045 1.14 0.805 20.4 1.055 26.80 1.148 29.16 831 85
4 2 6 0.045 1.14 0.870 22.1 1.120 28.45 1.207 30.66 945 100
4 1 4 0.055 1.40 1.003 25.5 1.253 31.83 1.340 34.04 1173 115
4 1/0 4 0.055 1.40 1.096 27.8 1.346 34.19 1.443 36.65 1322 135
4 2/0 4 0.055 1.40 1.195 30.4 1.443 36.65 1.537 39.04 1530 150
4 3/0 4 0.055 1.40 1.311 33.3 1.561 39.65 1.666 42.32 1801 175
4 4/0 4 0.055 1.40 1.436 36.5 1.686 42.82 1.791 45.49 2125 205
4 250 2 0.065 1.65 1.580 40.1 1.935 49.15 2.040 51.82 2647 230
4 300 2 0.065 1.65 1.660 42.2 2.000 50.80 2.130 54.10 3043 260
4 350 2 0.065 1.65 1.786 45.4 2.096 53.24 2.201 55.91 3348 280
4 400 2 0.065 1.65 1.888 48.0 2.198 55.83 2.303 58.50 3802 305
4 500 1 0.065 1.65 2.075 52.7 2.385 60.58 2.516 63.91 4501 350
4 600 1 0.080 2.03 2.326 59.1 2.636 66.95 2.767 70.28 5190 385
4 750 1/0 0.080 2.03 2.602 66.1 2.912 73.96 3.003 76.28 6187 435

UL1569-MC cable