1000V TECK90 Cable For Oil And Gas Power Distribution

1000V TECK90 Cable For Oil And Gas Power Distribution
Details:
·Conductor: 1 AWG. Thru 1000 kcmil. compact round concentric lay class "B" stranded copper
·Insulation: Cross-linked Polyethylene(XLPE) Type RW 90
·Colour Coding: Black
·Bonding Conductor(Ground): Concentrically wrapped uninsulated bare solid copper conductor. Polypropylene wrap applied around ground conductors
·Innerjacket: Polyvinyl Chloride (PVC), black
·Armor: Aluminum interlocked armour(AIA)
·Outer Jacket: Low acid gas, flame-retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC), black
·CSA License: 80322923
·Rated Voltage: 600V,1000V
·Application: Underground Mining,Oil & Gas Facilities,Industrial Power Distribution,Power Generation Plants,Water & Wastewater Treatment Plants
Send Inquiry
Download
Description
Technical Parameters
Certification

Dongguan Greater Wire & Cable Co., Ltd. is one of the leading manufacturers and suppliers of 1000v teck90 cable for oil and gas power distribution in China, also supports customized service. Please rest assured to wholesale durable 1000v teck90 cable for oil and gas power distribution made in China here from our factory. If you have any enquiry about free sample, please feel free to email us.

 

single conductor TECK90 cable for mine fixed equipment

PRODUCT REAL SHOT

 

mining distribution cabinet TECK90 cablemining distribution cabinet TECK90 cable

 

TECK90 cable for mining distribution cabinet
single conductor TECK90 cable for mining distribution cabinet

oil and gas facility TECK90 cable

Armoured Single Conductor Supply for Refinery Infrastructure
At a refinery, cable selection begins with the classified area, route and installation method. TECK90 cable for oil and gas can be considered for fixed power feeders where its exact certification, termination system and local electrical rules permit use. The single-conductor copper design incorporates XLPE insulation, concentric bonding copper wires, an inner PVC sheath, aluminum interlocked armour and an outer PVC jacket. GERITEL WIRE encourages buyers to share the area classification and project cable schedule; any hazardous-location claim must be checked against the certificate for the specific supplied product. Environmental exposure and area classification must be evaluated independently of a general product name.
PRODUCT SPECIFICATIONS

 

TECK90 cable for oil and gas facility

Application

 

For concealed wiring in dry or wet locations
For exposed wiring in dry or wet locations
For exposed and wiring in dry, locations where subjected to corrosive action if suitable for corrosive conditions encountered

For exposed wiring where subjected to the weather
For use in ventilated, Non-ventilated and ladder-type cable trays in dry or wet locations
For direct earth burial (with protection as required by inspection authority)
For service entrance above or below ground

SPECIFICATIONS
Conductor 1 AWG. Thru 1000 kcmil. compact round concentric lay class "B" stranded copper
Insulation Cross-linked Polyethylene (XLPE) Type RW 90
Color Coding

Black

Bonding Conductor(Ground) Concentrically wrapped uninsulated bare solid copper conductor. Polypropylene wrap applied around ground conductors
Inner Jacket Polyvinyl Chloride (PVC), black
Armour Aluminum interlocked armour(AIA)
Outer Jacket Low acid gas, flame-retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC), black
CSA License

80322923

Rated Voltage 600V,1000V
Features

Rated at 90°C wet or dry

Excellent crush resistance

Provides long service life

Cost effective alternative to installations in conduit

Meets cold bend and impact tests at (-40°C)

Compliances

Industry compliances: CSA Standard C22.2 No. 131, No.38 andNo.2256, RoHS
Flame test compliances: CSA FT4

Hazardous Location,SUN RES (outer jacket) SUN RES on inner jacket and insulated conductor available upon request, Direct Burial

Acid Gas: CSA AG14

TECK90- COPPER CONDUCTOR

SINGLE CONDUCTOR #1 AWG THRU 1000 kcmil

XLPE/ALUMINUM ARMOURED/1000 V, (-40°C) CSA

NO OF

COND.

COND.

SICE

(AWG/

kcmil)

GROUND

WIRE SIZE

(AWG/

kcmil)

MIN. AVG.

INSULATION

THICKNESS

NOMINAL DIAMETER(OVER) NET WEIGHT
INNER JACKET ARMOUR CABLE
INCHES mm INCHES mm INCHES mm INCHES mm KG/KM LBS/1000'
1 1 4 0.080 2.03 0.693 17.6 0.893 22.68 0.980 24.89 1065 716
1 1/0 4 0.080 2.03 0.730 18.5 0.980 24.89 1.067 27.10 1190 800
1 2/0 4 0.080 2.03 0.778 19.8 1.029 26.14 1.115 28.32 1370 921
1 3/0 3 0.080 2.03 0.827 21.0 1.077 27.36 1.164 29.57 1615 1085
1 4/0 3 0.080 2.03 0.869 22.1 1.119 28.42 1.206 30.63 1821 1224
1 250 2 0.090 2.29 0.975 24.8 1.225 31.12 1.312 33.32 2185 1468
1 300 2 0.090 2.29 1.025 26.0 1.275 32.39 1.362 34.59 2460 1653
1 350 1 0.090 2.29 1.071 27.2 1.321 33.55 1.408 35.76 2800 1882
1 400 1 0.090 2.29 1.114 28.3 1.364 34.65 1.451 36.86 3060 2056
1 500 1/0 0.090 2.29 1.214 30.8 1.464 37.19 1.551 39.40 3700 2486
1 600 1/0 0.090 2.29 1.291 32.8 1.541 39.14 1.644 41.76 4250 2856
1 750 2/0 0.090 2.29 1.414 35.9 1.714 43.54 1.817 46.15 5300 3562
1 1000 2/0 0.090 2.29 1.552 39.4 1.852 47.04 1.955 49.66 6500 4368
CERTIFICATIONS

 

single conductor TECK90 cable for oil and gas facility

PACKAGING

 

oil refinery TECK90 cable

Roll

TECK90 cable for oil refinery

Small Wooden Reel

single conductor TECK90 cable for oil refinery

Large Wooden Reel

APPLICATION

 

petrochemical plant TECK90 cable
Industrial Power Distribution
TECK90 cable for petrochemical plant
Underground Mining
single conductor TECK90 cable for petrochemical plant
Oil & Gas Facilities
CASE

 

chemical processing plant TECK90 cable

Canada Bobcaygeon Swing Bridge Rehabilitation Project

TECK90 cable for chemical processing plant

Canada Giant Mine Remediation Project

single conductor TECK90 cable for chemical processing plant

Canada Humboldt Wastewater Treatment Plant Upgrade Project

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

petroleum processing facility TECK90 cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

TECK90 cable for petroleum processing facility
 
single conductor TECK90 cable for petroleum processing facility
 
industrial oil and gas power distribution TECK90 cable
 
TECK90 cable for industrial oil and gas power distribution
 
single conductor TECK90 cable for industrial oil and gas power distribution
 
refinery electrical distribution TECK90 cable
 
GLOBAL CERTIFICATIONS

 

TECK90 cable for refinery electrical distribution

CUSTOMER PHOTOS
 

single conductor TECK90 cable for refinery electrical distribution

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

chemical plant power distribution TECK90 cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

TECK90 cable for chemical plant power distribution
single conductor TECK90 cable for chemical plant power distribution
process pump feeder TECK90 cable
TECK90 cable for process pump feeder
single conductor TECK90 cable for process pump feeder
oil terminal power distribution TECK90 cable
TECK90 cable for oil terminal power distribution
single conductor TECK90 cable for oil terminal power distribution
pipeline pump station TECK90 cable
TECK90 cable for pipeline pump station
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

single conductor TECK90 cable for pipeline pump station
FAQ

 

Can 1000V TECK90 be used on a 600V distribution system?
A 1000V-rated TECK90 cable may be considered for a 600V system when its installation, equipment connections and the applicable code permit it. The higher cable voltage marking alone does not establish compatibility with every protective device or cable fitting, so confirm the full circuit design.
Will a larger TECK90 conductor always carry more current?
At otherwise comparable conditions, a larger copper conductor generally supports a higher thermal current limit, but TECK90 cable ampacity is not a simple size-only comparison. Cable arrangement, ambient temperature, installation environment and termination ratings can change the permissible current.
Is TECK90 suitable for long feeder runs?
TECK90 feeder cable can be used for long fixed circuits when engineering calculations confirm voltage drop, fault current capability, conductor size and installation practicality. Large-section conductors may be chosen to manage losses, but no distance can be guaranteed from the TECK90 name alone.
Does aluminum interlocked armour carry the normal load current?
In a typical single conductor TECK90 power cable, the main copper conductor carries the intended circuit current; the interlocked armour is a protective metallic layer, not a substitute for the phase conductor. Bonding and fault-current paths must be designed in accordance with the approved cable system.

 

Hot Tags: 1000v teck90 cable for oil and gas power distribution, China 1000v teck90 cable for oil and gas power distribution manufacturers, suppliers, factory

Send Inquiry