Details:
·Conductor: 1 AWG. Thru 1000 kcmil. compact round concentric lay class "B" stranded copper
·Insulation: Cross-linked Polyethylene(XLPE) Type RW 90
·Colour Coding: Black
·Bonding Conductor(Ground): Concentrically wrapped uninsulated bare solid copper conductor. Polypropylene wrap applied around ground conductors
·Innerjacket: Polyvinyl Chloride (PVC), black
·Armor: Aluminum interlocked armour(AIA)
·Outer Jacket: Low acid gas, flame-retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC), black
·CSA License: 80322923
·Rated Voltage: 600V,1000V
·Application: Underground Mining,Oil & Gas Facilities,Industrial Power Distribution,Power Generation Plants,Water & Wastewater Treatment Plants
Send Inquiry
Download
Description
Technical Parameters
Certification

Dongguan Greater Wire & Cable Co., Ltd. is one of the leading manufacturers and suppliers of 90 degree rw90 teck90 cable for wet and dry locations in China, also supports customized service. Please rest assured to wholesale durable 90 degree rw90 teck90 cable for wet and dry locations made in China here from our factory. If you have any enquiry about free sample, please feel free to email us.

 

TECK90-HL 600V cable

PRODUCT REAL SHOT

 

TECK90-HL 1000V cable

 

TECK90-HL copper conductor
TECK90-HL aluminum conductor

TECK90-HL XLPE insulated cable

Thermoset Insulation for Canadian Industrial Power Systems
Temperature claims are useful only when their meaning is clear. In an RW90 TECK90 cable, the insulation designation refers to the rated conductor temperature in the specified dry and wet service conditions, not an unconditional cable ampacity for every installation. The single-core 1000V design commonly uses stranded copper, concentric bonding wires, PVC inner jacket, aluminum interlocked armour and PVC outer covering. GERITEL WIRE helps buyers review the project conditions, including ambient temperature, grouping, terminations and code rules, before a feeder is selected or ordered. Operating temperature and allowable current are not interchangeable product ratings.
PRODUCT SPECIFICATIONS

 

TECK90-HL FT4 cable

Application

 

For concealed wiring in dry or wet locations
For exposed wiring in dry or wet locations
For exposed and wiring in dry, locations where subjected to corrosive action if suitable for corrosive conditions encountered

For exposed wiring where subjected to the weather
For use in ventilated, Non-ventilated and ladder-type cable trays in dry or wet locations
For direct earth burial (with protection as required by inspection authority)
For service entrance above or below ground

SPECIFICATIONS
Conductor 1 AWG. Thru 1000 kcmil. compact round concentric lay class "B" stranded copper
Insulation Cross-linked Polyethylene (XLPE) Type RW 90
Color Coding

Black

Bonding Conductor(Ground) Concentrically wrapped uninsulated bare solid copper conductor. Polypropylene wrap applied around ground conductors
Inner Jacket Polyvinyl Chloride (PVC), black
Armour Aluminum interlocked armour(AIA)
Outer Jacket Low acid gas, flame-retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC), black
CSA License

80322923

Rated Voltage 600V,1000V
Features

Rated at 90°C wet or dry

Excellent crush resistance

Provides long service life

Cost effective alternative to installations in conduit

Meets cold bend and impact tests at (-40°C)

Compliances

Industry compliances: CSA Standard C22.2 No. 131, No.38 andNo.2256, RoHS
Flame test compliances: CSA FT4

Hazardous Location,SUN RES (outer jacket) SUN RES on inner jacket and insulated conductor available upon request, Direct Burial

Acid Gas: CSA AG14

TECK90- COPPER CONDUCTOR

SINGLE CONDUCTOR #1 AWG THRU 1000 kcmil

XLPE/ALUMINUM ARMOURED/1000 V, (-40°C) CSA

NO OF

COND.

COND.

SICE

(AWG/

kcmil)

GROUND

WIRE SIZE

(AWG/

kcmil)

MIN. AVG.

INSULATION

THICKNESS

NOMINAL DIAMETER(OVER) NET WEIGHT
INNER JACKET ARMOUR CABLE
INCHES mm INCHES mm INCHES mm INCHES mm KG/KM LBS/1000'
1 1 4 0.080 2.03 0.693 17.6 0.893 22.68 0.980 24.89 1065 716
1 1/0 4 0.080 2.03 0.730 18.5 0.980 24.89 1.067 27.10 1190 800
1 2/0 4 0.080 2.03 0.778 19.8 1.029 26.14 1.115 28.32 1370 921
1 3/0 3 0.080 2.03 0.827 21.0 1.077 27.36 1.164 29.57 1615 1085
1 4/0 3 0.080 2.03 0.869 22.1 1.119 28.42 1.206 30.63 1821 1224
1 250 2 0.090 2.29 0.975 24.8 1.225 31.12 1.312 33.32 2185 1468
1 300 2 0.090 2.29 1.025 26.0 1.275 32.39 1.362 34.59 2460 1653
1 350 1 0.090 2.29 1.071 27.2 1.321 33.55 1.408 35.76 2800 1882
1 400 1 0.090 2.29 1.114 28.3 1.364 34.65 1.451 36.86 3060 2056
1 500 1/0 0.090 2.29 1.214 30.8 1.464 37.19 1.551 39.40 3700 2486
1 600 1/0 0.090 2.29 1.291 32.8 1.541 39.14 1.644 41.76 4250 2856
1 750 2/0 0.090 2.29 1.414 35.9 1.714 43.54 1.817 46.15 5300 3562
1 1000 2/0 0.090 2.29 1.552 39.4 1.852 47.04 1.955 49.66 6500 4368
CERTIFICATIONS

 

TECK90-HL interlocked aluminum armour

PACKAGING

 

TECK90-HL wet location cable

Roll

TECK90-HL PVC inner jacket

Small Wooden Reel

TECK90-HL outdoor cable options

Large Wooden Reel

APPLICATION

 

TECK90-HL oil and gas cable
Industrial Power Distribution
TECK90-HL refinery electrical cable
Underground Mining
TECK90-HL petrochemical project cable
Oil & Gas Facilities
CASE

 

TECK90-HL mining project cable

Canada Bobcaygeon Swing Bridge Rehabilitation Project

TECK90-HL CSA C22.2 No. 174

Canada Giant Mine Remediation Project

TECK90-HL cable gland selection

Canada Humboldt Wastewater Treatment Plant Upgrade Project

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

TECK90-HL technical datasheet
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

TECK90-HL price per meter
 
TECK90-HL cable factory China
 
TECK90-HL EPC project supplier
 
TECK90 vs TECK90-HL
 
TECK90 and TECK90-HL difference
 
what does HL mean on cable
 
GLOBAL CERTIFICATIONS

 

hazardous location cable vs regular cable

CUSTOMER PHOTOS
 

is TECK90 HL required

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

TECK90 HL vs regular TECK90
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

when to use TECK90-HL
CSA hazardous location cable selection guide
CSA C22.2 No. 174 vs No. 131
AC90-HL vs TECK90-HL
TECK90 HL cableHL cable glands vs standard cable glands
hazardous location cable marking requirements
hazardous area armoured cable selection
ordinary location vs hazardous location cable Canada
armoured cable for commercial buildings Canada
armoured cable for residential apartments
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

armoured cable for industrial facilities
FAQ

 

Can conductor size determine TECK90 overall diameter by itself?
No. The outer diameter of 1000V TECK90 cable depends on insulation thickness, concentric bond construction, inner and outer jacket thickness, armour design and manufacturing tolerances. Request the exact size-specific datasheet instead of estimating gland or tray space from conductor area alone.
Should all TECK90 sizes use the same gland?
No. TECK90 cable gland selection depends on the finished outer diameter, armour interface, jacket details and environment, which change by conductor size. Large single-core designs may also require specific bonding and nonmagnetic hardware; confirm each fitting's certified application.
Can a supplier offer cut lengths of single-core TECK90?
Some manufacturers and distributors quote cut-to-length single core TECK90 cable, subject to production and packaging conditions. Give the exact size, number of pieces, total metres, reel limits and delivery destination to obtain a usable quotation rather than a generic per-metre price.
Why is the same TECK90 conductor size not always interchangeable across brands?
Two suppliers' TECK90 cable products with the same nominal copper size may differ in outer diameter, weight, gland compatibility, bend limits and listing details. Check the full construction drawing and certification file before treating a substitute as electrically and mechanically equivalent.

 

Hot Tags: 90 degree rw90 teck90 cable for wet and dry locations, China 90 degree rw90 teck90 cable for wet and dry locations manufacturers, suppliers, factory

Send Inquiry