TECK90 Single Core Cable For Water Treatment Facilities

TECK90 Single Core Cable For Water Treatment Facilities
Details:
·Conductor: 1 AWG. Thru 1000 kcmil. compact round concentric lay class "B" stranded copper
·Insulation: Cross-linked Polyethylene(XLPE) Type RW 90
·Colour Coding: Black
·Bonding Conductor(Ground): Concentrically wrapped uninsulated bare solid copper conductor. Polypropylene wrap applied around ground conductors
·Innerjacket: Polyvinyl Chloride (PVC), black
·Armor: Aluminum interlocked armour(AIA)
·Outer Jacket: Low acid gas, flame-retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC), black
·CSA License: 80322923
·Rated Voltage: 600V,1000V
·Application: Underground Mining,Oil & Gas Facilities,Industrial Power Distribution,Power Generation Plants,Water & Wastewater Treatment Plants
Send Inquiry
Download
Description
Technical Parameters
Certification

Dongguan Greater Wire & Cable Co., Ltd. is one of the leading manufacturers and suppliers of teck90 single core cable for water treatment facilities in China, also supports customized service. Please rest assured to wholesale durable teck90 single core cable for water treatment facilities made in China here from our factory. If you have any enquiry about free sample, please feel free to email us.

 

TECK90 cable for wastewater lift station

PRODUCT REAL SHOT

 

single conductor TECK90 cable for wastewater lift station

 

industrial water treatment TECK90 cable
TECK90 cable for industrial water treatment

single conductor TECK90 cable for industrial water treatment

Copper Armoured Power Feeds for Pumps and Plant Equipment
A water-treatment facility may run power between pump rooms, process buildings and outdoor electrical assets. TECK90 single core cable is worth evaluating for those fixed power circuits because its common construction combines copper, XLPE insulation, concentric bonding conductors and interlocked armour with PVC layers. Suitability still depends on wet-location ratings, installation details and the selected fittings. GERITEL WIRE can support project buyers with cable-list checking, drum planning and technical submittal preparation so the ordered cable is matched to the actual equipment route. Installation details such as glands and bonding arrangements should be reviewed at design stage.
PRODUCT SPECIFICATIONS

 

water utility power distribution TECK90 cable

Application

 

For concealed wiring in dry or wet locations
For exposed wiring in dry or wet locations
For exposed and wiring in dry, locations where subjected to corrosive action if suitable for corrosive conditions encountered

For exposed wiring where subjected to the weather
For use in ventilated, Non-ventilated and ladder-type cable trays in dry or wet locations
For direct earth burial (with protection as required by inspection authority)
For service entrance above or below ground

SPECIFICATIONS
Conductor 1 AWG. Thru 1000 kcmil. compact round concentric lay class "B" stranded copper
Insulation Cross-linked Polyethylene (XLPE) Type RW 90
Color Coding

Black

Bonding Conductor(Ground) Concentrically wrapped uninsulated bare solid copper conductor. Polypropylene wrap applied around ground conductors
Inner Jacket Polyvinyl Chloride (PVC), black
Armour Aluminum interlocked armour(AIA)
Outer Jacket Low acid gas, flame-retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC), black
CSA License

80322923

Rated Voltage 600V,1000V
Features

Rated at 90°C wet or dry

Excellent crush resistance

Provides long service life

Cost effective alternative to installations in conduit

Meets cold bend and impact tests at (-40°C)

Compliances

Industry compliances: CSA Standard C22.2 No. 131, No.38 andNo.2256, RoHS
Flame test compliances: CSA FT4

Hazardous Location,SUN RES (outer jacket) SUN RES on inner jacket and insulated conductor available upon request, Direct Burial

Acid Gas: CSA AG14

TECK90- COPPER CONDUCTOR

SINGLE CONDUCTOR #1 AWG THRU 1000 kcmil

XLPE/ALUMINUM ARMOURED/1000 V, (-40°C) CSA

NO OF

COND.

COND.

SICE

(AWG/

kcmil)

GROUND

WIRE SIZE

(AWG/

kcmil)

MIN. AVG.

INSULATION

THICKNESS

NOMINAL DIAMETER(OVER) NET WEIGHT
INNER JACKET ARMOUR CABLE
INCHES mm INCHES mm INCHES mm INCHES mm KG/KM LBS/1000'
1 1 4 0.080 2.03 0.693 17.6 0.893 22.68 0.980 24.89 1065 716
1 1/0 4 0.080 2.03 0.730 18.5 0.980 24.89 1.067 27.10 1190 800
1 2/0 4 0.080 2.03 0.778 19.8 1.029 26.14 1.115 28.32 1370 921
1 3/0 3 0.080 2.03 0.827 21.0 1.077 27.36 1.164 29.57 1615 1085
1 4/0 3 0.080 2.03 0.869 22.1 1.119 28.42 1.206 30.63 1821 1224
1 250 2 0.090 2.29 0.975 24.8 1.225 31.12 1.312 33.32 2185 1468
1 300 2 0.090 2.29 1.025 26.0 1.275 32.39 1.362 34.59 2460 1653
1 350 1 0.090 2.29 1.071 27.2 1.321 33.55 1.408 35.76 2800 1882
1 400 1 0.090 2.29 1.114 28.3 1.364 34.65 1.451 36.86 3060 2056
1 500 1/0 0.090 2.29 1.214 30.8 1.464 37.19 1.551 39.40 3700 2486
1 600 1/0 0.090 2.29 1.291 32.8 1.541 39.14 1.644 41.76 4250 2856
1 750 2/0 0.090 2.29 1.414 35.9 1.714 43.54 1.817 46.15 5300 3562
1 1000 2/0 0.090 2.29 1.552 39.4 1.852 47.04 1.955 49.66 6500 4368
CERTIFICATIONS

 

TECK90 cable for water utility power distribution

PACKAGING

 

single conductor TECK90 cable for water utility power distributionsingle conductor TECK90 cable for water utility power distribution

Roll

waterworks electrical installation TECK90 cable

Small Wooden Reel

TECK90 cable for waterworks electrical installation

Large Wooden Reel

APPLICATION

 

single conductor TECK90 cable for waterworks electrical installation
Industrial Power Distribution
treatment plant motor feeder TECK90 cable
Underground Mining
TECK90 cable for treatment plant motor feeder
Oil & Gas Facilities
CASE

 

single conductor TECK90 cable for treatment plant motor feeder

Canada Bobcaygeon Swing Bridge Rehabilitation Project

municipal infrastructure power TECK90 cable

Canada Giant Mine Remediation Project

TECK90 cable for municipal infrastructure power

Canada Humboldt Wastewater Treatment Plant Upgrade Project

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

single conductor TECK90 cable for municipal infrastructure power
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

stormwater pumping station TECK90 cable
 
TECK90 cable for stormwater pumping station
 
single conductor TECK90 cable for stormwater pumping station
 
desalination plant TECK90 cable
 
TECK90 cable for desalination plant
 
single conductor TECK90 cable for desalination plant
 
GLOBAL CERTIFICATIONS

 

industrial wastewater facility TECK90 cable

CUSTOMER PHOTOS
 

TECK90 cable for industrial wastewater facility

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

single conductor TECK90 cable for industrial wastewater facility
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

water plant switchgear TECK90 cable
TECK90 cable for water plant switchgear
single conductor TECK90 cable for water plant switchgear
power generation plant TECK90 cable
TECK90 cable for power generation plant
single conductor TECK90 cable for power generation plant
thermal power plant TECK90 cable
TECK90 cable for thermal power plant
single conductor TECK90 cable for thermal power plant
hydropower facility TECK90 cable
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

TECK90 cable for hydropower facility
FAQ

 

Is TECK90 suitable for direct burial?
Direct burial TECK90 cable is a recognized option for eligible constructions and jurisdictions. Confirm direct-burial marking, burial depth, bedding, mechanical protection and local inspection requirements. Not every cable carrying the TECK90 name should be assumed to have an identical burial approval.
What does a -40°C marking mean for TECK90?
A -40°C TECK90 cable rating often refers to specified cold-bend and cold-impact testing of the assembly or jacket. It does not automatically mean the cable may be handled, pulled or bent at -40°C. Confirm the minimum installation temperature separately from low-temperature material performance.
Is TECK90 suitable for a corrosive industrial atmosphere?
TECK90 industrial cable is frequently selected for challenging industrial environments, but resistance to any particular chemical depends on jacket formulation, exposure duration and concentration. For wastewater plants, refineries or chemical processing sites, compare the proposed sheath data with the actual substances present.
Does TECK90 resist oil exposure?
Some oil-resistant TECK90 cable products offer verified performance against relevant oil exposure tests. The phrase "oil resistant" should only appear on a specific product page if supported by the approved design and test documentation; it does not mean resistance to every solvent or fuel.

 

Hot Tags: teck90 single core cable for water treatment facilities, China teck90 single core cable for water treatment facilities manufacturers, suppliers, factory

Send Inquiry