H07V-K 35 Mm² Flexible Cable For Switchgear And Equipment Bonding

H07V-K 35 Mm² Flexible Cable For Switchgear And Equipment Bonding
Details:
·Conductor: Class 5 flexible copper conductor
·Insulation: PVC (Polyvinyl Chloride)
·Voltage Rating Uo/U: H05V-K:300/500V ; H07V-K:450/750V
·Temperature Rating: Fixed: -30°C to +70℃ ; Flexed: -5°C to +70℃
·Standards: EN 50525-2-31, EN 60228 ; Flame Retardant according to IEC/EN 60332-1-2 ; UV Resistant
Send Inquiry
Download
Description
Technical Parameters
Certification

H07V-K 35mm2 cable

PRODUCT REAL SHOT

 

H07V-K 35mm2 cable
35mm2 H07V-K cable
35 sq mm H07V-K wire

H07V-K 35 mm2 wire

35 mm² Switchgear Earth Wire for Protected Industrial Panels
A 35 mm² H07V-K conductor can be relevant in larger switchgear and equipment assemblies where protected internal power or protective-conductor routes need both copper capacity and handling flexibility. Used as 35 mm² switchgear cable, it can simplify routing to terminals, bonded metalwork or suitable electrical devices inside the enclosure. For grounding functions, an equipment bonding conductor must be identified and sized according to the applicable PE design rather than chosen only because green/yellow insulation is available. GERITEL WIRE can support colour, marking and project packing. As flexible protective earth wire, the final bonding path, fault duty, termination hardware and local standard must be confirmed.
PRODUCT SPECIFICATIONS

 

2491X H07V-K 35mm2 cable

Applications

 

PVC panel wiring for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.

SPECIFICATIONS
Voltage Rating Uo/U

H05V-K:300/500V

H07V-K:450/750V

Temperature Rating

Fixed: -30°C to +70°C

Flexed: -5°C to +70°C

Minimum Bending Radius Fixed: 6 x overall diameter
Conductor Class 5 flexible copper conductor
Insulation PVC (Polyvinyl Chloride)
Insulation Colour Red,Black,Blue,Orange,Yellow,White,Green/Yellow,Violet,Pink,Grey,Brown
STANDARDS

EN 50525-2-31,EN 60228

Flame Retardant according to IEC/EN 60332-1-2

UV Resistant

DIMENSIONS

NOMINAL CROSS SECTIONAL AREA

mm²

NOMINAL OVERALL DIAMETER

mm²

NOMINAL WEIGHT

kg/km

H05V-K
0.5 2.20 9.1
0.75 2.40 11.7
1 2.55 14.4
H07V-K
1.5 3.00 20.1
2.5 3.65 31.5
4 4.20 46.2
6 4.80 65.1
10 6.25 109.4
16 7.40 165.2
25 9.40 253.4
35 10.40 345.5
50 12.55 492.4
70 14.10 669.3
95 17.20 910.4
120 17.70 1129.4
150 19.60 1401.0
185 23.00 1741.0
240 26.40 2267.5

CONDUCTORS

NOMINAL CROSS

SECTIONAL AREA

mm²

MAXIMUM DIAMETER

OF WIRES IN CONDUCTOR

mm

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Plain Wires
0.5 0.21 39
0.75 0.21 26
1 0.21 19.5
1.5 0.26 13.3
2.5 0.26 7.98
4 0.31 4.95
6 0.31 3.3
10 0.41 1.91
16 0.41 1.21
25 0.41 0.78
35 0.41 0.554
50 0.41 0.386
70 0.51 0.272
95 0.51 0.206
120 0.51 0.161
150 0.51 0.129
185 0.51 0.106
240 0.51 0.0801

ELECTRICAL CHARACTERISTICS

NOMINAL CROSSS

ECTIONAL AREA

mm²

REFERENCE METHOD A

(ENCLOSED IN

CONDUIT IN THERMALLY

INSULATING WALL ETC)

Amps

REFERENCE METHOD B

(ENCLOSED IN CONDUIT

IN WALL OR IN

TRUNKING ETC)
Amps

REFERENCE METHOD C

(CLIPPED DIRECT)
Amps

REFERENCE METHOD F

(IN FREE AIR OR ONA PERFORATED CABLE TRAY ETC HORIZONTAL OR VERTICAL ETC)

Amps

Touching

Spaced by

one diameter

2 Cables Single-Phase ACor DC or3 Cables Three-Phase AC flat

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

AC or DC

3 or 4Cables

Three-Phase

AC

2Cables

SinglePhase

AC or DCflat

3Cables

Three-Phase

ACflat

3 Cables

Three-Phase

ACtrefoil

Horizontal Vertical
1.5 14.5 13.5 17.5 15.5 20 18 - - - - -
2.5 20 18 24 21 27 25 - - - - -
4 26 24 32 28 37 33 - - - - -
6 34 31 41 36 47 43 - - - - -
10 46 42 57 50 65 59 - - - - -
16 61 56 76 68 87 79 - - - - -
25 80 73 101 89 114 104 131 114 110 146 130
35 99 89 125 110 141 129 162 143 137 181 162
50 119 108 151 134 182 167 196 174 167 219 192
70 151 136 192 171 234 214 251 225 216 281 254
95 182 164 232 207 284 261 304 275 264 341 311
120 210 188 269 239 330 303 352 321 308 396 362
150 240 216 300 262 381 349 406 372 356 456 419
185 273 245 341 296 436 400 463 427 409 521 480
240 321 286 400 346 515 472 546 507 485 615 569
CERTIFICATIONS

 

2491X 35mm2 cable

H07VK 35mm2 wire

PACKAGING

 

07V-K 35mm2 cable

Roll

35mm2 flexible panel wire

Plastic Reel

35mm2 panel wire

Small Wooden Reel

APPLICATION

 

35mm2 single core flexible cable
Industrial Control Panel
35mm2 PVC single core wire
Renewable Energy Power Connection
35mm2 Class 5 flexible wire

Switchboard Wiring

 

CASE

 

35mm2 flexible copper wire

Adelaide Airport Switchboard Upgrade

35mm2 control cabinet wire

Industrial Main Switchboard Power Distribution

35mm2 equipment wire

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

35mm2 450/750V flexible cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

H07V-K 35mm2 datasheet
 
H07V-K 35mm2 current rating
 
H07V-K 35mm2 amp rating
 
H07V-K 35mm2 current carrying capacity
 
H07V-K 35mm2 conductor resistance
 
H07V-K 35mm2 cable diameter
 
GLOBAL CERTIFICATIONS

 

H07V-K 35mm2 cable weight

CUSTOMER PHOTOS
 

EN 50525-2-31 35mm2 cable

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

IEC 60228 Class 5 35mm2 wire
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

H07V-K 35mm2 technical specification
35mm2 switchgear internal wire
35mm2 distribution panel wire
35mm2 motor control panel wire
35mm2 machine control cabinet wire
35mm2 building conduit wire
35mm2 switchboard wire
35mm2 control panel power wire
35mm2 EV charger cabinet wire
35mm2 energy storage cabinet wire
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

35mm2 data center earthing wire
FAQ

 

Can H07V-K replace a bare copper earth conductor?
An insulated grounding conductor and a bare copper earth conductor can serve different installation needs. H07V-K may be appropriate for protected flexible bonding, but buried grids, lightning protection or exposed earthing systems often require other constructions. For distributors, GERITEL WIRE can plan repeat supply by colour and packaging format so warehouse stock is easier to manage across different customer applications.
What is the difference between H05V-K and H07V-K?
The key H05V-K vs H07V-K difference is voltage class: H05V-K is typically 300/500 V while H07V-K is 450/750 V. Both use flexible Class 5 conductors, so choose from circuit voltage and the applicable product standard. GERITEL WIRE applies incoming-material and finished-product quality controls and can discuss available inspection records or project documentation for the ordered construction.
What is the difference between H07V-K and H07V-U?
H07V-K vs H07V-U mainly compares conductor construction: K uses fine-stranded Class 5 copper, while U uses a solid Class 1 conductor. H07V-K is easier to route in dense panels; H07V-U is more rigid. Where certification matters, GERITEL WIRE can check the exact certificate scope for the ordered product instead of relying on a general brand-level approval claim.
What is the difference between H07V-K and H07V-R?
H07V-K vs H07V-R compares Class 5 flexible conductor with the more rigid Class 2 stranded conductor used in H07V-R. The better choice depends on routing flexibility, installation method and terminal system. GERITEL WIRE can support OEM identification and private-label packaging when the marking and compliance requirements are confirmed before production.

 

Hot Tags: h07v-k 35 mm² flexible cable for switchgear and equipment bonding, China h07v-k 35 mm² flexible cable for switchgear and equipment bonding manufacturers, suppliers, factory, HO7V-K

Send Inquiry