50 Mm² Flexible Earth Wire For H07V-K Industrial Grounding Systems

50 Mm² Flexible Earth Wire For H07V-K Industrial Grounding Systems
Details:
·Conductor: Class 5 flexible copper conductor
·Insulation: PVC (Polyvinyl Chloride)
·Voltage Rating Uo/U: H05V-K:300/500V ; H07V-K:450/750V
·Temperature Rating: Fixed: -30°C to +70℃ ; Flexed: -5°C to +70℃
·Standards: EN 50525-2-31, EN 60228 ; Flame Retardant according to IEC/EN 60332-1-2 ; UV Resistant
Send Inquiry
Download
Description
Technical Parameters
Certification

35mm2 modular house panel wire

PRODUCT REAL SHOT

 

35mm2 equipment bonding wire
H07V-K 35mm2 cable price
H07V-K 35mm2 wire supplier

H07V-K 35mm2 cable manufacturer

H07V-K 50 mm² Equipotential Bonding Cable for Electrical Equipment
Large electrical cabinets, machine frames and industrial distribution equipment often require substantial protective conductors between earth bars and bonded metal parts. H07V-K can be used as 50 mm² grounding cable where a flexible insulated Class 5 conductor is suitable for the fixed or protected bonding route. The same construction may serve as industrial bonding wire in equipment rooms and switchboards, helping installers route copper around structural obstacles more easily. GERITEL WIRE can support green/yellow identification, OEM labels and heavy-duty packaging. An electrical cabinet earth conductor must still be sized from the fault-current and earthing design, with compatible lugs and secure bonding points.
PRODUCT SPECIFICATIONS

 

35mm2 panel wire supplier

Applications

 

PVC panel wiring for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.

SPECIFICATIONS
Voltage Rating Uo/U

H05V-K:300/500V

H07V-K:450/750V

Temperature Rating

Fixed: -30°C to +70°C

Flexed: -5°C to +70°C

Minimum Bending Radius Fixed: 6 x overall diameter
Conductor Class 5 flexible copper conductor
Insulation PVC (Polyvinyl Chloride)
Insulation Colour Red,Black,Blue,Orange,Yellow,White,Green/Yellow,Violet,Pink,Grey,Brown
STANDARDS

EN 50525-2-31,EN 60228

Flame Retardant according to IEC/EN 60332-1-2

UV Resistant

DIMENSIONS

NOMINAL CROSS SECTIONAL AREA

mm²

NOMINAL OVERALL DIAMETER

mm²

NOMINAL WEIGHT

kg/km

H05V-K
0.5 2.20 9.1
0.75 2.40 11.7
1 2.55 14.4
H07V-K
1.5 3.00 20.1
2.5 3.65 31.5
4 4.20 46.2
6 4.80 65.1
10 6.25 109.4
16 7.40 165.2
25 9.40 253.4
35 10.40 345.5
50 12.55 492.4
70 14.10 669.3
95 17.20 910.4
120 17.70 1129.4
150 19.60 1401.0
185 23.00 1741.0
240 26.40 2267.5

CONDUCTORS

NOMINAL CROSS

SECTIONAL AREA

mm²

MAXIMUM DIAMETER

OF WIRES IN CONDUCTOR

mm

MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C

ohms/km

Plain Wires
0.5 0.21 39
0.75 0.21 26
1 0.21 19.5
1.5 0.26 13.3
2.5 0.26 7.98
4 0.31 4.95
6 0.31 3.3
10 0.41 1.91
16 0.41 1.21
25 0.41 0.78
35 0.41 0.554
50 0.41 0.386
70 0.51 0.272
95 0.51 0.206
120 0.51 0.161
150 0.51 0.129
185 0.51 0.106
240 0.51 0.0801

ELECTRICAL CHARACTERISTICS

NOMINAL CROSSS

ECTIONAL AREA

mm²

REFERENCE METHOD A

(ENCLOSED IN

CONDUIT IN THERMALLY

INSULATING WALL ETC)

Amps

REFERENCE METHOD B

(ENCLOSED IN CONDUIT

IN WALL OR IN

TRUNKING ETC)
Amps

REFERENCE METHOD C

(CLIPPED DIRECT)
Amps

REFERENCE METHOD F

(IN FREE AIR OR ONA PERFORATED CABLE TRAY ETC HORIZONTAL OR VERTICAL ETC)

Amps

Touching

Spaced by

one diameter

2 Cables Single-Phase ACor DC or3 Cables Three-Phase AC flat

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

ACor DC

3 or 4 Cables

Three-Phase

AC

2 Cables

Single-Phase

AC or DC

3 or 4Cables

Three-Phase

AC

2Cables

SinglePhase

AC or DCflat

3Cables

Three-Phase

ACflat

3 Cables

Three-Phase

ACtrefoil

Horizontal Vertical
1.5 14.5 13.5 17.5 15.5 20 18 - - - - -
2.5 20 18 24 21 27 25 - - - - -
4 26 24 32 28 37 33 - - - - -
6 34 31 41 36 47 43 - - - - -
10 46 42 57 50 65 59 - - - - -
16 61 56 76 68 87 79 - - - - -
25 80 73 101 89 114 104 131 114 110 146 130
35 99 89 125 110 141 129 162 143 137 181 162
50 119 108 151 134 182 167 196 174 167 219 192
70 151 136 192 171 234 214 251 225 216 281 254
95 182 164 232 207 284 261 304 275 264 341 311
120 210 188 269 239 330 303 352 321 308 396 362
150 240 216 300 262 381 349 406 372 356 456 419
185 273 245 341 296 436 400 463 427 409 521 480
240 321 286 400 346 515 472 546 507 485 615 569
CERTIFICATIONS

 

2491X 35mm2 cable supplier

H07V-K 35mm2 wholesale cable

PACKAGING

 

H07V-K 35mm2 OEM supplier

Roll

H07V-K 50mm2 cable

Plastic Reel

H07V-K 50 mm2 wire

Small Wooden Reel

APPLICATION

 

H07V-K 50mm2 cable
Industrial Control Panel
50mm2 H07V-K cable
Renewable Energy Power Connection
50 sq mm H07V-K wire

Switchboard Wiring

 

CASE

 

2491X H07V-K 50mm2 cable

Adelaide Airport Switchboard Upgrade

2491X 50mm2 cable

Industrial Main Switchboard Power Distribution

H07VK 50mm2 wire

Main Switchboard Flexible Cable Replacement

WHY CHOOSE US

 

30Years of experience
in one-stop service

Dongguan Greater Wire & Cable Co., Ltd. is a professional engineering-grade cable manufacturer in China, supplying certified electrical cable solutions for building, industrial, mining, energy, and infrastructure projects worldwide.

With a 30,000 m² factory, 30 production lines, experienced engineers, and a strict quality control team, we provide reliable, traceable, and compliant cable products for international engineering applications. Our products are supported by certifications including SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, and ISO.

We are committed to safety, quality, transparency, and long-term partnership. From raw material inspection to finished product testing, every batch is carefully controlled to ensure stable performance and dependable project use.

Greater Cable - Certified Quality. Reliable Supply. Engineering Value.

07V-K 50mm2 cable
 
15K
Finished Projects
150+
professional staff
15K
happy clients
92+
awards & certifacates
PLANT EQUIPMENT

 

50mm2 flexible panel wire
 
50mm2 panel wire
 
50mm2 single core flexible cable
 
50mm2 PVC single core wire
 
50mm2 Class 5 flexible wire
 
50mm2 flexible copper wire
 
GLOBAL CERTIFICATIONS

 

50mm2 control cabinet wire

CUSTOMER PHOTOS
 

50mm2 equipment wire

INTERNATIONL TRANSPORTATION

 

01

Sea Freight

We offer reliable sea freight solutions for large-volume orders. Your goods are securely packed and shipped in containers, ensuring cost-effective delivery to ports worldwide.

02

Air Freight

For faster delivery, our air freight service ensures your products reach international destinations quickly, with careful handling and full tracking along the way.

03

International Express

Need urgent shipments? Our international express service delivers small to medium orders efficiently, providing door-to-door service with real-time tracking for peace of mind.

50mm2 450/750V flexible cable
COOPERATIVE PARTNER

 

We are looking for a cooperative partner to expand our business.

H07V-K 50mm2 datasheet
H07V-K 50mm2 current rating
H07V-K 50mm2 amp rating
H07V-K 50mm2 current carrying capacity
H07V-K 50mm2 conductor resistance
H07V-K 50mm2 cable diameter
50mm2 switchboard internal wiring cable
50mm2 distribution board flexible cable
IEC 60228 Class 5 50mm2 wire
50mm2 equipment power wiring cable
How To Cooperate With Us?

Simply share your requirements, receive our professional solution, confirm samples, and enjoy fast, reliable production and worldwide delivery - working with us is that easy.

Our address

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Phone Number

+86 136 6257 9592

+86 135 1078 4550

E-mail

manager01@greaterwire.com

50mm2 flexible earth wire
FAQ

 

What is the difference between H07V-K and H07V-R?
H07V-K vs H07V-R compares Class 5 flexible conductor with the more rigid Class 2 stranded conductor used in H07V-R. The better choice depends on routing flexibility, installation method and terminal system. GERITEL WIRE can support OEM identification and private-label packaging when the marking and compliance requirements are confirmed before production.
What is H07V-K vs H07Z1-K?
H07V-K vs H07Z1-K is mainly PVC versus a low-smoke halogen-free panel-wire construction. Choose the LSZH option where smoke and corrosive-gas performance is required by the fire strategy or CPR specification. For engineering buyers, GERITEL WIRE can compare the requested installation with the cable construction and flag when another cable family would be technically safer.
What is H07V-K vs H07V2-K?
H07V-K vs H07V2-K typically involves a standard PVC harmonised wire versus a higher-temperature or multi-standard panel-wire family, depending on the manufacturer. Always compare the exact datasheets and approvals. GERITEL WIRE can align production packing with panel-shop handling, automated wire processing or distributor stocking requirements for repeat orders.
Should I use H07V-K or tri-rated cable?
Use H07V-K where the European harmonised specification meets the project. Choose tri rated panel wire when the same panel must satisfy applicable BS, UL and CSA requirements for export markets. If the project has several circuits or destination markets, GERITEL WIRE can help separate H07V-K applications from circuits that need LSZH, screened, high-temperature or continuous-flex cable.

 

Hot Tags: 50 mm² flexible earth wire for h07v-k industrial grounding systems, China 50 mm² flexible earth wire for h07v-k industrial grounding systems manufacturers, suppliers, factory, HO7V-K

Send Inquiry